Rapid method for on-site determination of atrazine residues in water samples.: Assay optimisation

被引:4
|
作者
Gabaldón, JA [1 ]
Maquieira, A [1 ]
Puchades, R [1 ]
机构
[1] Univ Politecn Valencia, Dept Quim, E-46071 Valencia, Spain
关键词
immunofiltration; membranes; dipstick; atrazine; water;
D O I
10.1080/716064519
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive dipstick immunoassay for atrazine has been developed. The optimisation of different parameters, such as substrate dilution, assay time and simultaneous versus sequential protocol, by means of an immunofiltration device is described. The assay is based on the competitive principle and uses a polyclonal antibody immobilized on an Immobilon-P membrane and alkaline phosphatase as enzyme tracer. The test takes about 10min and has a visual detection limit for atrazine of 10mugL(-1). Cross-reactivity of polyclonal sera to atrazine and propazine are similar, decreasing 10-fold for simazine and terbuthylazine and 100-fold for prometryn and ametryn. Based on the good reproducibility obtained (90% of positive response) the developed dipsticks can be very useful as a qualitative or semiquantitative on-site test for atrazine determination in water samples.
引用
收藏
页码:133 / 144
页数:12
相关论文
共 50 条
  • [1] Method for detecting atrazine in water samples.
    Bilyeu, AE
    Acheson, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U321 - U321
  • [2] RAPID IMMUNOFILTRATION ASSAY FOR THE DETERMINATION OF ATRAZINE IN WATER AND SOIL SAMPLES
    DANKWARDT, A
    HOCK, B
    BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8): : R20 - R21
  • [3] Determination of atrazine residues in red wine samples. A conductimetric solution
    Valera, Enrique
    Ramon-Azcon, Javier
    Barranco, Alejandro
    Alfaro, Begona
    Sanchez-Baeza, Francisco
    Marco, M. -P.
    Rodriguez, Angel
    FOOD CHEMISTRY, 2010, 122 (03) : 888 - 894
  • [4] Development and evaluation of a dipstick immunoassay format for the determination of atrazine residues on-site
    Wittmann, C
    Bilitewski, U
    Giersch, T
    Kettling, U
    Schmid, RD
    ANALYST, 1996, 121 (06) : 863 - 869
  • [5] Rapid on-site determination of chlorobenzene in water samples using ion mobility spectrometry
    Borsdorf, H
    Rämmler, A
    Schulze, D
    Boadu, KO
    Feist, B
    Weiss, H
    ANALYTICA CHIMICA ACTA, 2001, 440 (01) : 63 - 70
  • [6] Gold Immunochromatographic Assay for Rapid On-Site Detection of Lincosamide Residues in Milk, Egg, Beef, and Honey Samples
    Guo, Lingling
    Wu, Xiaoling
    Liu, Liqiang
    Kuang, Hua
    Xu, Chuanlai
    BIOTECHNOLOGY JOURNAL, 2020, 15 (01)
  • [7] Rapid immunoanalytical method for the determination of atrazine residues in olive oil
    Garcés-García, M
    Morais, S
    Gonzaález-Martínez, MA
    Puchades, R
    Maquieira, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) : 484 - 489
  • [8] Rapid immunoanalytical method for the determination of atrazine residues in olive oil
    Marta Garcés-García
    Sergi Morais
    Miguel Ángel González-Martínez
    Rosa Puchades
    Ángel Maquieira
    Analytical and Bioanalytical Chemistry, 2004, 378 : 484 - 489
  • [9] Rapid method for on-site determination of phenolic contaminants in water using a disposable biosensor
    Yuanting Li
    Dawei Li
    Wei Song
    Meng Li
    Jie Zou
    Yitao Long
    Frontiers of Environmental Science & Engineering, 2012, 6 : 831 - 838
  • [10] Rapid method for on-site determination of phenolic contaminants in water using a disposable biosensor
    Li, Yuanting
    Li, Dawei
    Song, Wei
    Li, Meng
    Zou, Jie
    Long, Yitao
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2012, 6 (06) : 831 - 838