Comparison of Frequency-Specific Hearing Thresholds between Pure-Tone Audiometry and Auditory Steady-State Response

被引:4
|
作者
Swami, Himanshu [1 ]
Kumar, Santosh [2 ]
机构
[1] Command Hosp Airforce, Dept ENT HNS, Bangalore, Karnataka, India
[2] Mil Hosp, Dept ENT, Roorkee, Uttarakhand, India
关键词
Auditory steady-state response; hearing threshold; pure-tone audiometry; BRAIN-STEM RESPONSE; EVOKED-RESPONSES; ADULTS; CHILDREN; MASTER;
D O I
10.4103/indianjotol.INDIANJOTOL_97_18
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Introduction: Hearing assessment in difficult to assess persons gives inconsistent response in free field hearing and pure-tone audiometry (PTA). We have been performing brainstem evoked response audiometry (BERA) as an objective assessment in such cases. BERA has limitations that it is not frequency specific, measures thresholds in higher frequencies only, signal intensity levels cannot be higher than 90 dB and presents the data in waveform which needs to be interpreted by experienced audiologist to deduce correct information. All these limitations can be negated with use of auditory steady-state response (ASSR) which can present intensity levels till 120 dB, is frequency specific, even for lower frequencies and has automated response and deduction analysis. The aim of our study was to compare pure-tone thresholds with ASSR thresholds in normal hearing and hearing loss subjects with an objective to validate the ASSR as a tool for objective hearing assessment. Materials and Methods: In this prospective cross-sectional study of 70 adults (n = 140 ears) of both genders, with and without hearing complaints, Group 1 consisted of 24 individuals of normal hearing, Group 2 consisted of 25 individuals of sensorineural hearing loss, and 21 individuals with conductive hearing loss in Group 3. The patients were evaluated with PTA and ASSR test. The mean pure tone and ASSR thresholds for each frequency were calculated and analyzed using the SPSS IBM software. Results: The mean difference of ASSR with PTA was noted at 9.92 dB in the right ear and 10 dB in the left ear. A high significant correlation was noted between ASSR and PTA with P (0.0005) across all the three groups. The relationship between the PTA and ASSR measurement for measuring average hearing threshold levels is described by the equation: PTA = ASSR mean x 0.99-9.92. Conclusion: ASSR is an excellent tool to predict accurate level of frequency-specific hearing threshold. It has constant relationship with pure tone thresholds. ASSR can predict true hearing thresholds in "difficult to assess" patients such as children and malingerers. This can also be used in the prediction of disability assessment objectively.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [1] Discrepancies in Hearing Thresholds between Pure-Tone Audiometry and Auditory Steady-State Response in Non-Malingerers
    Noh, Heil
    Lee, Dong-Hee
    [J]. EAR AND HEARING, 2020, 41 (03): : 663 - 668
  • [2] Comparison between auditory steady-state responses and pure-tone audiometry
    Komazec, Zoran
    Lemajic-Komazec, Slobodanka
    Jovic, Rajko
    Nadj, Congor
    Jovancevic, Ljiljana
    Savovic, Slobodan
    [J]. VOJNOSANITETSKI PREGLED, 2010, 67 (09) : 761 - 765
  • [3] Adults with Auditory Neuropathy: Comparison of Auditory Steady-State Response and Pure-Tone Audiometry
    Jafari, Zahra
    Malayeri, Saeed
    Ashayeri, Hassan
    Farahani, Mahdi Azizabadi
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2009, 20 (10) : 621 - 628
  • [4] A Controlled Comparison of Auditory Steady-State Responses and Pure-Tone Audiometry in Patients with Hearing Loss
    Wadhera, Raman
    Hernot, Sharad
    Gulati, Sat Paul
    Kalra, Vijay
    [J]. ENT-EAR NOSE & THROAT JOURNAL, 2017, 96 (10-11) : E47 - E52
  • [5] Comparing pure-tone audiometry and auditory steady state response for the measurement of hearing loss
    Ahn, Joong Ho
    Lee, Hyo-Sook
    Kim, Young-Jin
    Yoon, Tae Hyun
    Chung, Jong Woo
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2007, 136 (06) : 966 - 971
  • [6] Assessing Agreement between Frequency-Specific Chirp Auditory Steady-State Response and Pure Tone Audiometry in Adults by Intraclass Correlation Coefficient
    Chen, Mo
    Wei, Yi
    Wang, Xianren
    Liu, Liman
    Liu, Min
    Jiang, Guangli
    Wei, Fanqin
    [J]. ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, 2022, 84 (01): : 30 - 38
  • [7] Comparison of pure tone audiometry and auditory steady-state responses in subjects with normal hearing and hearing loss
    Ali Ozdek
    Mahmut Karacay
    Guleser Saylam
    Emel Tatar
    Nurdan Aygener
    Mehmet Hakan Korkmaz
    [J]. European Archives of Oto-Rhino-Laryngology, 2010, 267 : 43 - 49
  • [8] Comparison of pure tone audiometry and auditory steady-state responses in subjects with normal hearing and hearing loss
    Ozdek, Ali
    Karacay, Mahmut
    Saylam, Guleser
    Tatar, Emel
    Aygener, Nurdan
    Korkmaz, Mehmet Hakan
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2010, 267 (01) : 43 - 49
  • [9] Comparative study between pure tone audiometry and auditory steady-state responses in normal hearing subjects
    de Oliveira Beck, Roberto Miquelino
    Ramos, Bernardo Faria
    Grasel, Signe Schuster
    Ramos, Henrique Faria
    de Moraes, Maria Flavia Bonadia B.
    de Almeida, Edigar Rezende
    Bento, Ricardo Ferreira
    [J]. BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2014, 80 (01) : 35 - 40
  • [10] THRESHOLDS OF HEARING AS DETERMINED BY BRAIN-STEM RESPONSE AND PURE-TONE AUDIOMETRY
    VANDERDRIFT, JFC
    BROCAAR, MP
    VANZANTEN, GA
    [J]. CLINICAL OTOLARYNGOLOGY, 1985, 10 (04): : 226 - 226