Comparison of the Biomechanical Changes After Percutaneous Full-Endoscopic Anterior Cervical Discectomy versus Posterior Cervical Foraminotomy at C5-C6: A Finite Element-Based Study

被引:20
|
作者
Yuchi, Chen-Xi [1 ,2 ]
Sun, Guiming [3 ]
Chen, Chao [3 ]
Liu, Gang [3 ]
Zhao, Dong [3 ]
Yang, Haiyun [3 ]
Xu, Baoshan [3 ]
Deng, Shucai [3 ]
Ma, Xinlong [3 ]
Du, Cheng-Fei [1 ,2 ]
Yang, Qiang [3 ]
机构
[1] Tianjin Univ Technol, Sch Mech Engn, Tianjin Key Lab Adv Machatron Syst Design & Intel, Tianjin, Peoples R China
[2] Tianjin Univ Technol, Natl Demonstrat Ctr Expt Alechameal & Elect Engn, Tianjin, Peoples R China
[3] Tianjin Hosp, Dept Spine Surg, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomechanics; Finite element study; Percutaneous full-endoscopic anterior cervical discectomy; Posterior cervical foraminotomy; STRUCTURAL-PROPERTIES; DISC REPLACEMENT; SPINE; SEGMENT; STABILITY; MOTION; VALIDATION; PREDICTION; COMPONENTS; STRENGTHS;
D O I
10.1016/j.wneu.2019.05.025
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Percutaneous full-endoscopic anterior cervical discectomy (PEACD) and posterior cervical foraminotomy (PCF) have been reported as effective treatments for the cervical spondylosis radiculopathy (CSR), but the biomechanical effects on the discs and facet joints of PEACD and PCF remain largely unclear. The purpose of this paper is to investigate and compare the biomechanical changes on cervical spine after PECAD and PCF procedures, thus providing evidences for surgeons to select a more appropriate approach. METHODS: An intact cervical C5-C6 digital model was constructed and then modified to obtain the PCF and PEACD models using finite element method. All the models were subjected to a 73.6N preload accompanied by a 1.8 Nm moment during flexion, extension, axial rotation, lateral bending. The range of motion (ROM), intervertebral disc pressure (IDP), facet joint contact area, and contact pressure were calculated under different loading conditions. RESULTS: The ROM of the PCF model changed slightly (0.28%), whereas that of the PEACD model increased significantly (20.49%) compared with intact model. The trend of IDP changes in these 2 surgical models were similar to ROM in the corresponding motion state. The contact pressure on the facet joint of the PEACD model increased by 20.53%, 33.38%, and 17.46% during extension, lateral bending, and axial bending, respectively, compared with the intact model, and the PCF increased by 33.53% and 16.16% during extension and lateral bending, respectively, whereas it decreased 0.97% in axial rotation. The facet joint contact area of the PCF model increased by 85.71%, 1.54%, and 2.17% during extension, lateral bending, and axial rotation, respectively, and the area of the PEACD model increased by 157.14% and 36.96% during extension and axial rotation, whereas it decreased by 13.85% during lateral bending. CONCLUSIONS: This is the first biomechanical finite element study comparing PEACD with PCF for the treatment of CSR. Our results showed that PEACD led to hypermobility with high IDP within the cervical segment undergone surgery, whereas the ROM and IDP changed slightly after PCF. The variations of the contact stress indicated that both procedures changed the transmission path of the force on the facet joint and may accelerate the degeneration of the facet joint. PCF may be a better choice for the treatment of CSR compared with PEACD.
引用
收藏
页码:E905 / E911
页数:7
相关论文
共 17 条
  • [1] Percutaneous posterior full-endoscopic cervical foraminotomy and discectomy: a finite element analysis and radiological assessment
    Ke, Wencan
    Zhi, Jinggang
    Hua, Wenbin
    Wang, Bingjin
    Lu, Saideng
    Fan, Lina
    Li, Li
    Yang, Cao
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (12) : 805 - 814
  • [2] A Finite Element Analysis of Anterior Cervical Discectomy and Fusion Compared with Percutaneous Full-endoscopic Anterior Cervical Discectomy
    Du, Cheng-Fei
    Yuchi, Chen-Xi
    Cai, Xin-Yi
    Sun, Meng-Si
    2019 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2019, : 1311 - 1315
  • [3] Comparison of Cervical Sagittal Alignment and Kinematics after Posterior Full-endoscopic Cervical Foraminotomy and Discectomy According to Preoperative Cervical Alignment
    Won, Samuel
    Kim, Chi Heon
    Chung, Chun Kee
    Choi, Yunhee
    Park, Sung Bae
    Moon, Jung Hyeon
    Heo, Won
    Kim, Sung-Mi
    PAIN PHYSICIAN, 2017, 20 (02) : 77 - 87
  • [4] Biomechanical Comparison of Optimal Shapes for the Cervical Intervertebral Fusion Cage for C5-C6 Cervical Fusion Using the Anterior Cervical Plate and Cage (ACPC) Fixation System: A Finite Element Analysis
    Wang, Jiajia
    Qian, Zhihui
    Ren, Luquan
    MEDICAL SCIENCE MONITOR, 2019, 25 : 8379 - 8388
  • [5] Association between extent of simulated degeneration of C5-C6 disc and biomechanical parameters of a model of the full cervical spine: a finite element analysis study
    Li, Yuan
    Lewis, Gladius
    JOURNAL OF APPLIED BIOMATERIALS & BIOMECHANICS, 2010, 8 (03) : 191 - 199
  • [6] Biomechanical effect of C5-C6 intervertebral disc degeneration on the human lower cervical spine (C3-C7): a finite element study
    Rahman, Waseem Ur
    Jiang, Wei
    Zhao, Fulin
    Li, Zhijun
    Wang, Guohua
    Yang, Guanghui
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (07) : 820 - 834
  • [7] Biomechanical Effect of C5/C6 Intervertebral Reconstructive Height on Adjacent Segments in Anterior Cervical Discectomy and Fusion - A Finite Element Analysis
    Zhou, Jia-ming
    Guo, Xing
    Kang, Liang
    Zhao, Rui
    Yang, Xiao-tian
    Fu, Yi-bin
    Xue, Yuan
    ORTHOPAEDIC SURGERY, 2021, 13 (04) : 1408 - 1416
  • [8] Patterns of Height Changes in Anterior and Posterior Cervical Disc Regions Affects the Contact Loading at Posterior Facets During Moderate and Severe Disc Degeneration A Poroelastic C5-C6 Finite Element Model Study
    Hussain, Mozammil
    Natarajan, Raghu N.
    An, Howard S.
    Andersson, Gunnar B. J.
    SPINE, 2010, 35 (18) : E873 - E881
  • [9] Level-specific Perioperative and Clinical Outcome Comparison: Cervical Disk Replacement Versus Anterior Cervical Diskectomy and Fusion at C5-C6 in Patients With Myeloradiculopathy
    Jacob, Kevin C.
    Patel, Madhav R.
    Parsons, Alexander W.
    Prabhu, Michael C.
    Ribot, Max A.
    Pawlowski, Hanna
    Vanjani, Nisheka N.
    Singh, Kern
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (17) : E1137 - E1147
  • [10] A Biomechanical Comparison of Three Different Posterior Fixation Constructs Used for C6-C7 Cervical Spine Immobilization: A Finite Element Study
    Hong, Jae Taek
    Qasim, Muhammad
    Espinoza Orias, Alejandro A.
    Natarajan, Raghu N.
    An, Howard S.