Experimental studies of gypsum plasterboards and composite panels under fire conditions

被引:17
|
作者
Kolarkar, Prakash [1 ]
Mahendran, Mahen [1 ]
机构
[1] Queensland Univ Technol, Fac Sci & Engn, Brisbane, Qld 4000, Australia
基金
澳大利亚研究理事会;
关键词
gypsum plasterboard; composite panels; insulation; standard fire tests; thermal performance; KINETICS;
D O I
10.1002/fam.2155
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Gypsum plasterboards are commonly used to protect the light gauge steel-framed walls in buildings from fires. Single or multiple plasterboards can be used for this purpose, whereas recent research has proposed a composite panel with a layer of external insulation between two plasterboards. However, a good understanding of the thermal behaviour of these plasterboard panels under fire conditions is not known. Therefore, 15 small-scale fire tests were conducted on plasterboard panels made of 13 and 16mm plasterboards and four different types of insulations with varying thickness and density subject to standard fire conditions in AS 1530.4. Fire performance of single and multiple layers of gypsum plasterboards was assessed including the effects of interfaces between adjacent plasterboards. Effects of using external insulations such as glass fibre, rockwool and cellulose fibre were also determined. The thermal performance of composite panels developed from different insulating materials of varying densities and thicknesses was examined and compared. This paper presents the details of the fire tests conducted in this study and their valuable time-temperature data for the tested plasterboard panels. These data can be used for the purpose of developing and validating accurate thermal numerical models of these panels. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:13 / 35
页数:23
相关论文
共 50 条
  • [1] Experimental and Numerical Analysis of Gypsum Plasterboards in Fire
    Frangi, Andrea
    Schleifer, Vanessa
    Fontana, Mario
    Hugi, Erich
    FIRE TECHNOLOGY, 2010, 46 (01) : 149 - 167
  • [2] Experimental and Numerical Analysis of Gypsum Plasterboards in Fire
    Andrea Frangi
    Vanessa Schleifer
    Mario Fontana
    Erich Hugi
    Fire Technology, 2010, 46 : 149 - 167
  • [3] Gypsum plasterboards under natural fire—Experimental investigations of thermal properties
    Zehfuß, Jochen
    Sander, Lisa
    Civil Engineering Design, 2021, 3 (03) : 62 - 72
  • [4] Numerical studies of gypsum plasterboard panels under standard fire conditions
    Keerthan, Poologanathan
    Mahendran, Mahen
    FIRE SAFETY JOURNAL, 2012, 53 : 105 - 119
  • [5] Thermal Performance of Composite Panels Under Fire Conditions Using Numerical Studies: Plasterboards, Rockwool, Glass Fibre and Cellulose Insulations
    Keerthan, Poologanathan
    Mahendran, Mahen
    FIRE TECHNOLOGY, 2013, 49 (02) : 329 - 356
  • [6] Thermal Performance of Composite Panels Under Fire Conditions Using Numerical Studies: Plasterboards, Rockwool, Glass Fibre and Cellulose Insulations
    Poologanathan Keerthan
    Mahen Mahendran
    Fire Technology, 2013, 49 : 329 - 356
  • [7] Material Characterisation and Numerical Modelling of Gypsum Plasterboards in Fire
    Dodangoda, Maneesha Tharindi
    Mahendran, Mahen
    Poologanathan, Keerthan
    Frost, Ray L.
    STRUCTURES IN FIRE, 2016, : 1116 - 1123
  • [8] Fire safety aspects of PCM-enhanced gypsum plasterboards: An experimental and numerical investigation
    Asimakopoulou, Eleni K.
    Kolaitis, Dionysios I.
    Founti, Maria A.
    FIRE SAFETY JOURNAL, 2015, 72 : 50 - 58
  • [9] Mathematical and numerical analysis of dehydratation of gypsum plasterboards exposed to fire
    Belmiloudi, A
    Le Meur, G
    APPLIED MATHEMATICS AND COMPUTATION, 2005, 163 (03) : 1023 - 1041
  • [10] Short communication:: Fire protection of wood by different gypsum plasterboards
    Tsantaridis, LD
    Östman, BAL
    König, J
    FIRE AND MATERIALS, 1999, 23 (01) : 45 - 48