Design and study of an enhanced Faraday cup detector

被引:22
|
作者
Naieni, A. Kashefian [2 ]
Bahrami, F. [2 ]
Yasrebi, N. [2 ]
Rashidian, B. [1 ,2 ]
机构
[1] Ctr Excellence Nanostruct, Inst Nanosci & Technol, Tehran, Iran
[2] Sharif Univ Technol, Dept Elect Engn, Tehran, Iran
关键词
Faraday cup; Charged particle detection; Electrostatic guard ring;
D O I
10.1016/j.vacuum.2009.01.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Faraday cups (FCs) have been used to measure charged particle beams currents for a wide variety of experiments since the early days of particle accelerators. The major error source in FC performance is the escape of ejected electrons produced by energetic particles striking with interior metal surfaces of the FC. To avoid this problem, electrostatic and magnetic guard rings are used. Some kinds of non-symmetrical electrostatic FC with superior performance than traditional cylindrically symmetric FC have been reported. Here, we propose a novel non-symmetrical electrostatic FC structure, and a method to compare different non-symmetrical FCs. The purpose of this design is to recapture energetic electrons with lower guard ring bias. Performance simulations of the proposed FC show considerable improvement over other reported FCs. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1095 / 1099
页数:5
相关论文
共 50 条
  • [1] Performance enhancement study of an electrostatic Faraday cup detector
    Thomas, JD
    Hodges, GS
    Seely, DG
    Moroz, NA
    Kvale, TJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 536 (1-2): : 11 - 21
  • [3] Study on simulation and experiment of array micro Faraday cup ion detector for FAIMS
    Fei Tang
    XiaoHao Wang
    Liang Zhang
    ZiLin Yan
    Science China Technological Sciences, 2010, 53 : 3225 - 3231
  • [4] Study on simulation and experiment of array micro Faraday cup ion detector for FAIMS
    Tang Fei
    Wang XiaoHao
    Zhang Liang
    Yan ZiLin
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (12) : 3225 - 3231
  • [5] Study on simulation and experiment of array micro Faraday cup ion detector for FAIMS
    TANG Fei WANG XiaoHao ZHANG Liang YAN ZiLin State Key Laboratory of Precision Measurement Technology and Instruments Department of Precision Instruments and Mechanology Tsinghua University Beijing China
    Science China(Technological Sciences), 2010, 53 (12) : 3225 - 3231
  • [6] DESIGN AND CHARACTERIZATION OF A VERSATILE FARADAY CUP
    SEAMANS, JF
    KIMURA, WD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02): : 460 - 469
  • [7] Array micro Faraday cup ion current detector for FAIMS
    Tang F.
    Wang X.-H.
    Zhang L.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (12): : 2597 - 2602
  • [8] An improved design of Faraday cup detector to reduce the escape of secondary electrons in plasma focus device by COMSOL
    Roshani, G. H.
    Habibi, M.
    Sohrabi, M.
    VACUUM, 2011, 86 (03) : 250 - 253
  • [9] Faraday cup detector array with electronic multiplexing for multichannel mass spectrometry
    Scheidemann, AA
    Darling, RB
    Schumacher, FJ
    Isakharov, A
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2002, 20 (03): : 597 - 604
  • [10] Faraday-cup-type lost fast ion detector on Heliotron J
    Yamamoto, S.
    Ogawa, K.
    Isobe, M.
    Darrow, D. S.
    Kobayashi, S.
    Nagasaki, K.
    Okada, H.
    Minami, T.
    Kado, S.
    Ohshima, S.
    Weir, G. M.
    Nakamura, Y.
    Konoshima, S.
    Kemmochi, N.
    Ohtani, Y.
    Mizuuchi, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):