Modeling of Virtual Mechanical Circulatory Hemodynamics for Biventricular Heart Failure Support

被引:0
|
作者
Horvath, Dennis W. [1 ]
Polakowski, Anthony R. [2 ]
Flick, Christine [2 ]
Fukamachi, Kiyotaka [2 ]
Horvath, David J. [1 ]
Karimov, Jamshid H. [2 ]
机构
[1] R1 Engn LLC, Euclid, OH USA
[2] Case Western Reserve Univ, Lerner Res Inst, Dept Biomed Engn, Cleveland Clin,Lerner Coll Med,ND20, 9500 Euclid Ave,ND20, Cleveland, OH 44195 USA
关键词
Cardiovascular disease; Computer simulation; Mock circulation loop; Lumped parameter; Blood pumps; Heart failure; Biventricular failure; Disease modelling;
D O I
10.1007/s13239-020-00501-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective In this study, a mechanical circulatory support simulation tool was used to investigate the application of a unique device with two centrifugal pumps and one motor for the biventricular assist device (BVAD) support application. Several conditions-including a range of combined left and right systolic heart failure severities, aortic and pulmonary valve regurgitation, and combinations of high and low systemic and pulmonary vascular resistances-were considered in the simulation matrix. Relative advantages and limitations of using the device in BVAD applications are discussed. Methods The simulated BVAD pump was based on the Cleveland Clinic pediatric continuous-flow total artificial heart (P-CFTAH), which is currently under development. Different combined disease states (n = 10) were evaluated to model the interaction with the BVAD, considering combinations of normal heart, moderate failure and severe systolic failure of the left and right ventricles, regurgitation of the aortic and pulmonary valves and combinations of vascular resistance. The virtual mock loop simulation tool (MATLAB; MathWorks (R), Natick, MA) simulates the hemodynamics at the pump ports using a lumped-parameter model for systemic/pulmonary circulation characteristic inputs (values for impedance, systolic and diastolic ventricular compliance, beat rate, and blood volume), and characteristics of the cardiac chambers and valves. Results Simulation results showed that this single-pump BVAD can provide regulated support of up to 5 L/min over a range of combined heart failure states and is suitable for smaller adult and pediatric support. However, good self-regulation of the atrial pressure difference was not maintained with the introduction of aortic valve regurgitation or high systemic vascular resistance when combined with low pulmonary vascular resistance. Conclusions This initial in silico study demonstrated that use of the P-CFTAH as a BVAD supports cardiac output and arterial pressure in biventricular heart failure conditions. A similar but larger device would be required for a large adult patient who needs more than 5 L/min of support.
引用
收藏
页码:699 / 707
页数:9
相关论文
共 50 条
  • [1] Modeling of Virtual Mechanical Circulatory Hemodynamics for Biventricular Heart Failure Support
    Dennis W. Horvath
    Anthony R. Polakowski
    Christine Flick
    Kiyotaka Fukamachi
    David J. Horvath
    Jamshid H. Karimov
    [J]. Cardiovascular Engineering and Technology, 2020, 11 : 699 - 707
  • [2] Editorial: Mechanical circulatory support therapy for biventricular failure
    Karimov, Jamshid H.
    Fukamachi, Kiyotaka
    Masuzawa, Toru
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [3] Mechanical Circulatory Support for Biventricular Heart Failure Using Advanced Ventricular Assist Device
    Karimov, J. H.
    Horvath, D.
    Horvath, D.
    Kado, Y.
    Miyamoto, T.
    Kuban, B.
    Fukamachi, K.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S414 - S414
  • [4] The BEAT Device for Intrathoracic, Extracardiac Biventricular Mechanical Circulatory Support for Advanced Heart Failure
    Stock, U. A.
    Bowles, C.
    Hinkel, R.
    Fischer, J.
    Smail, H.
    Wildhirt, S.
    Schueler, S.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S183 - S183
  • [5] Factors associated with the need of biventricular mechanical circulatory support in children with advanced heart failure
    Fan, Ye
    Zhang, An-Mei
    Weng, Yu-Guo
    Huebler, Michael
    Miera, Oliver
    Franz, Norbert
    Qian, Gui-Sheng
    Hetzer, Roland
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (05) : 1028 - 1035
  • [6] Mechanical Circulatory Support for Biventricular Heart Failure Using Continuous-Flow Total Artificial Heart
    Karimov, J. H.
    Horvath, D.
    Byram, N.
    Polakowski, A.
    Adams, J.
    Kado, Y.
    Miyamoto, T.
    Sale, S.
    Kuban, B.
    Fukamachi, K.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S343 - S343
  • [7] Mechanical circulatory support in heart failure
    Szygula-Jurkiewicz, Bozena
    Szczurek, Wioletta
    Suliga, Kamil
    Rempega, Grzegorz
    Rajwa, Pawel
    [J]. KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2016, 13 (02): : 130 - 134
  • [8] Heart failure and mechanical circulatory support
    Esper, Stephen Andrew
    Subramaniam, Kathirvel
    [J]. BEST PRACTICE & RESEARCH-CLINICAL ANAESTHESIOLOGY, 2012, 26 (02) : 91 - 104
  • [9] MECHANISMS OF RIGHT VENTRICULAR FAILURE AND BIVENTRICULAR MECHANICAL CIRCULATORY SUPPORT
    Itkin, G. P.
    Poptsov, V. N.
    [J]. VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2013, 15 (04): : 126 - 135
  • [10] Effect of Mechanical Circulatory Support on Exercise Hemodynamics among Individuals with Advanced Heart Failure
    Cornwell, W. K.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S103 - S103