Cascaded Hough Transform-Based Hair Mask Generation and Harmonic Inpainting for Automated Hair Removal from Dermoscopy Images

被引:0
|
作者
Ashour, Amira S. [1 ]
El-Wahab, Basant S. Abd [1 ]
Wahba, Maram A. [1 ]
Mansour, Diaa-Eldin A. [2 ]
Hodeib, Abeer Abd Elhakam [3 ]
Khedr, Rasha Abd El-Ghany [4 ]
Hassan, Ghada F. R. [3 ]
机构
[1] Tanta Univ, Fac Engn, Dept Elect & Elect Commun Engn, Tanta 31511, Egypt
[2] Tanta Univ, Fac Engn, Dept Elect Power & Machines Engn, Tanta 31511, Egypt
[3] Tanta Univ, Fac Med, Dept Dermatol & Venereol, Tanta 31511, Egypt
[4] Tanta Univ, Fac Med, Dept Clin Oncol, Tanta 31511, Egypt
关键词
skin cancer; dermoscopy; hair mask generation; Hough transform; harmonic image inpainting; adaptive Wiener filter; ALGORITHM;
D O I
10.3390/diagnostics12123040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Restoring information obstructed by hair is one of the main issues for the accurate analysis and segmentation of skin images. For retrieving pixels obstructed by hair, the proposed system converts dermoscopy images into the L*a*b* color space, then principal component analysis (PCA) is applied to produce grayscale images. Afterward, the contrast-limited adaptive histogram equalization (CLAHE) and the average filter are implemented to enhance the grayscale image. Subsequently, the binary image is generated using the iterative thresholding method. After that, the Hough transform (HT) is applied to each image block to generate the hair mask. Finally, the hair pixels are removed by harmonic inpainting. The performance of the proposed automated hair removal was evaluated by applying the proposed system to the International Skin Imaging Collaboration (ISIC) dermoscopy dataset as well as to clinical images. Six performance evaluation metrics were measured, namely the mean squared error (MSE), the peak signal-to-noise ratio (PSNR), the signal-to-noise ratio (SNR), the structural similarity index (SSIM), the universal quality image index (UQI), and the correlation (C). Using the clinical dataset, the system achieved MSE, PSNR, SNR, SSIM, UQI, and C values of 34.7957, 66.98, 42.39, 0.9813, 0.9801, and 0.9985, respectively. The results demonstrated that the proposed system could satisfy the medical diagnostic requirements and achieve the best performance compared to the state-of-art.
引用
收藏
页数:14
相关论文
共 4 条
  • [1] SharpRazor: Automatic removal of hair and ruler marks from dermoscopy images
    Kasmi, Reda
    Hagerty, Jason
    Young, Reagan
    Lama, Norsang
    Nepal, Januka
    Miinch, Jessica
    Stoecker, William
    Stanley, R. Joe
    SKIN RESEARCH AND TECHNOLOGY, 2023, 29 (04)
  • [2] True digital hair removal with real value inpainting for improved dermoscopy based on image fusion
    Juette, Lennart
    Emmert, Steffen
    Roth, Bernhard
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2023, 2023, 12352
  • [3] Automated Hair Segmentation in Dermoscopy Images with U-Net Based Approaches
    Dogan, Musa
    Ozkan, Ilker Ali
    2024 13TH MEDITERRANEAN CONFERENCE ON EMBEDDED COMPUTING, MECO 2024, 2024, : 448 - 451
  • [4] VirtualShave: automated hair removal from digital dermatoscopic images
    Fiorese, M.
    Peserico, E.
    Silletti, A.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 5145 - 5148