Static cyclic response of masonry walls retrofitted with fiber-reinforced polymers

被引:84
|
作者
ElGawady, Mohamed A. [1 ]
Lestuzzi, Pierino
Badoux, Marc
机构
[1] Washington State Univ, Dept Civil & Environm Engn, Pullman, WA 99164 USA
[2] Ecole Polytech Fed Lausanne, ENAC, IMAC, IS, CH-1015 Lausanne, Switzerland
关键词
D O I
10.1061/(ASCE)1090-0268(2007)11:1(50)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The behavior of seven one-half scale masonry specimens before and after retrofitting using fiber-reinforced polymer (FRP) is investigated. Four walls were built using one-half scale hollow clay masonry units and weak mortar to simulate walls built in central Europe in the mid-20th century. Three walls were first tested as unreinforced masonry walls; then, the seismically damaged specimens were retrofitted using FRPs. The fourth wall was directly upgraded after construction using FRP., Each specimen was retrofitted on the entire surface of a single side. All the specimens were tested under constant gravity load and incrementally increasing in-plane loading cycles. The tested specimens had two effective moment/shear ratio, namely, 0.5 and 0.7. The key parameter was the amount of FRP axial rigidity, which is defined as the amount of FRP reinforcement ratio times its E modulus. The single-side retrofitting/upgrading significantly improved the lateral strength, stiffness, and energy dissipation of the test specimens. The increase in the lateral strength was proportional to the amount of FRP axial rigidity. However, using high amount of FRP axial rigidity led to very brittle failure. Finally, simple existing analytical models estimated the ultimate lateral strengths of the test specimens reasonably well.
引用
收藏
页码:50 / 61
页数:12
相关论文
共 50 条
  • [1] Masonry confinement with fiber-reinforced polymers
    Krevaikas, TD
    Triantafillou, TC
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (02) : 128 - 135
  • [2] In-plane cyclic loading tests of concrete hollow block masonry walls retrofitted with high ductile fiber-reinforced concrete
    Deng, Mingke
    Zhang, Wei
    Li, Ning
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2020, 238
  • [3] Cyclic behavior of perforated masonry walls strengthened with glass fiber reinforced polymers
    Kalali, A.
    Kabir, M. Z.
    [J]. SCIENTIA IRANICA, 2012, 19 (02) : 151 - 165
  • [4] Experimental Study of Solid and Hollow Clay Brick Masonry Walls Retrofitted by Steel Fiber-Reinforced Mortar Coating
    Facconi, Luca
    Minelli, Fausto
    Lucchini, Sara
    Plizzari, Giovanni
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2020, 24 (03) : 381 - 402
  • [5] In-plane cyclic response of unreinforced masonry walls retrofitted with ferrocement
    Hasnat, Abul
    Das, Tanmoy
    Ahsan, Raquib
    Alam, Ahmed Tohameem
    Ahmed, Hafiz
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [6] Effectiveness of anchorage in concrete beams retrofitted with sprayed fiber-reinforced polymers
    Lee, HK
    [J]. JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2004, 23 (12) : 1285 - 1300
  • [7] Static cyclic in-plane shear response of damaged masonry walls retrofitted with NSM FRP strips - An experimental evaluation
    Konthesingha, K. M. C.
    Masia, M. J.
    Petersen, R. B.
    Mojsilovic, N.
    Simundic, G.
    Page, A. W.
    [J]. ENGINEERING STRUCTURES, 2013, 50 : 126 - 136
  • [8] Static Cyclic Response of Partially Grouted Masonry Shear Walls
    Nolph, Shawn M.
    ElGawady, Mohamed A.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2012, 138 (07): : 864 - 879
  • [9] Static and cyclic loading of fiber-reinforced dental resin
    Drummond, JL
    Bapna, MS
    [J]. DENTAL MATERIALS, 2003, 19 (03) : 226 - 231
  • [10] Experimental investigations on reinforced concrete shear walls strengthened with basalt fiber-reinforced polymers under cyclic load
    Shen, Dejian
    Yang, Qun
    Jiao, Yang
    Cui, Zhenghua
    Zhang, Jinyang
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 136 : 217 - 229