Comparison of the Effect of Dual-Axis Rotational Coronary Angiography Versus Conventional Coronary Angiography on Frequency of Acute Kidney Injury, X-Ray Exposure Time, and Quantity of Contrast Medium Injected

被引:5
|
作者
Di Serafino, Luigi [1 ,2 ]
Turturo, Maurizio [1 ]
Lanzone, Saverio [1 ]
Marano, Melissa [1 ]
Scognamiglio, Gabriella [3 ]
Trimarco, Bruno [2 ]
Cirillo, Plinio [2 ]
Esposito, Giovanni [2 ]
D'Agostino, Carlo [1 ,4 ]
机构
[1] Venere Hosp, Div Cardiol, Bari, Italy
[2] Univ Naples Federico II, Dept Adv Biomed Sci, Div Cardiol, Naples, Italy
[3] San Giovanni Bosco Hosp, Div Cardiol, Naples, Italy
[4] Azienda Osped Univ Policlin Bari, Div Cardiol, Bari, Italy
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2018年 / 121卷 / 09期
关键词
ACUTE-RENAL-FAILURE; INDUCED NEPHROPATHY; PROGNOSTIC IMPLICATIONS; INTERVENTIONS;
D O I
10.1016/j.amjcard.2018.01.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-axis rotational coronary angiography (DARCA) has already been shown to reduce both the amount of contrast medium and radiation exposure compared with conventional coronary angiography (CCA). However, a clinical benefit of such imaging modality has never been demonstrated. The aim of this study was to evaluate the efficacy of DARCA to prevent acute kidney injury (AM) compared with CCA. Consecutive patients who underwent coronary angiography were enrolled to DARCA (n = 80) or CCA (n = 80). Patients presenting with ST-segment elevation myocardial infarction or previously underwent coronary artery bypass graft were excluded. The 2 groups were homogeneous in terms of both clinical and procedural characteristics. Total x-ray time and total amount of contrast medium were significantly lower in the DARCA group compared with the CCA group (x-ray time 3.2 minutes [1.8 to 7.0] vs 5.1 minutes [2.6 to 9.9], p = 0.002; contrast medium amount 40 ml [31 to 116] vs 80 ml [50 to 150], p <0.001). AKI more often occurred in the CCA group compared with the DARCA group (16 [20%] vs 4 [5%], p = 0.007). Moreover, in patients presenting with acute coronary syndrome (ACS) or who underwent percutaneous coronary intervention (PCI), AKI more often occurred in the CCA group compared with the DARCA group (ACS patients, 6 [29%] vs 2 [6 %], p = 0.04, and PCI patients, 11 [33 %] vs 0 [0 %], p <0.001). In addition, in patients with high pretest probability of coronary artery disease, AKI more often occurred in the CCA group compared with the DARCA group (11 [55%] vs 2 [6%], p <0.001). In conclusion, DARCA significantly reduces both x-ray exposure and amount of contrast medium usage, thereby reducing the occurrence of AKI compared with CCA. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:1046 / 1050
页数:5
相关论文
共 10 条
  • [1] Dual-axis rotational coronary angiography versus conventional coronary angiography: a randomized comparison
    Michaela M. Hell
    Melanie D. Gilg
    Jens Röther
    Florian Blachutzik
    Stephan Achenbach
    Christian Schlundt
    Clinical Research in Cardiology, 2021, 110 : 258 - 269
  • [2] Dual-axis rotational coronary angiography versus conventional coronary angiography: a randomized comparison
    Hell, Michaela M.
    Gilg, Melanie D.
    Roether, Jens
    Blachutzik, Florian
    Achenbach, Stephan
    Schlundt, Christian
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (02) : 258 - 269
  • [3] Comparison of Dual-Axis Rotational Coronary Angiography (XPERSWING) Versus Conventional Technique in Routine Practice
    Gomez-Menchero, Antonio E.
    Diaz, Jose F.
    Sanchez-Gonzalez, Carlos
    Cardenal, Rosa
    Sanghvi, Amit B.
    Roa-Garrido, Jessica
    Rodriguez-Lopez, Jose L.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2012, 65 (05): : 434 - 439
  • [4] Comparison of diagnostic accuracy of dual-axis rotational versus standard coronary angiography
    Zhi-Geng Jin
    Rui Bai
    Yi Li
    Yong Yang
    Wei Han
    Qing Zhao
    Lu Zhang
    Hui-Liang Liu
    The International Journal of Cardiovascular Imaging, 2020, 36 : 187 - 195
  • [5] Comparison of diagnostic accuracy of dual-axis rotational versus standard coronary angiography
    Jin, Zhi-Geng
    Bai, Rui
    Li, Yi
    Yang, Yong
    Han, Wei
    Zhao, Qing
    Zhang, Lu
    Liu, Hui-Liang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (02): : 187 - 195
  • [6] Randomized Comparison of Dual-Axis Rotational Versus Standard Coronary Angiography: A Non-inferiority Trial
    Jin, Zhigeng
    Liu, Huiliang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C169 - C169
  • [7] Radiation exposure, procedure time and contrast load in patients referred for coronary angiography: Head-to-head comparison of dual source Ct with conventional coronary angiography
    Van Mieghem, Carlos A.
    Weustink, Annick C.
    Koffland, Marcel
    Schreve-Steensma, A.
    Matheijssen, Niels A.
    den Boer, Ad
    de Feyter, J.
    CIRCULATION, 2007, 116 (16) : 575 - 575
  • [8] Comparison of Contrast Volume, Radiation Dose, Fluoroscopy Time, and Procedure Time in Previously Published Studies of Rotational Versus Conventional Coronary Angiography
    Loomba, Rohit S.
    Rios, Rodrigo
    Buelow, Matthew
    Eagam, Mamata
    Aggarwal, Saurabh
    Arora, Rohit R.
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (01): : 43 - 49
  • [9] Effect of renin-angiotensin-system blockers on contrast-medium-induced acute kidney injury after coronary angiography
    Goo, Ja-Jun
    Kim, Jae-Joon
    Kang, Ji-Hoon
    Kim, Kyoung-Nyoun
    Byun, Ki-Sup
    Kim, Mi-kyung
    Kim, Tae-Ik
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2014, 29 (02): : 203 - 209
  • [10] Effect of reduced x-ray tube voltage, low iodine concentration contrast medium, and sinogram-affirmed iterative reconstruction on image quality and radiation dose at coronary CT angiography: Results of the prospective multicenter REALISE trial
    Yin, Wei-Hua
    Lu, Bin
    Gao, Jian-Bo
    Li, Pei-Ling
    Sun, Kai
    Wu, Zhi-Feng
    Yang, Wen-Jie
    Zhang, Xiao-Qin
    Zheng, Min-Wen
    McQuiston, Andrew D.
    Meinel, Felix G.
    Schoepf, Uwe Joseph
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (03) : 215 - 224