Evidence on Synthesized Two-dimensional Mammography Versus Digital Mammography When Using Tomosynthesis (Three-dimensional Mammography) for Population Breast Cancer Screening

被引:22
|
作者
Houssami, Nehmat [1 ]
机构
[1] Univ Sydney, Sydney Sch Publ Hlth, Sydney Med Sch, Sydney, NSW, Australia
关键词
BC; Digital breast tomosynthesis; False-positive recall; Population screening; Synthesized imaging; RECONSTRUCTED PROJECTION IMAGES; SYNTHETIC MAMMOGRAPHY; 2D MAMMOGRAPHY; PERFORMANCE; TRIAL; DBT; IMPLEMENTATION; COMBINATION; PROGRAM;
D O I
10.1016/j.clbc.2017.09.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
One limitation of using digital breast tomosynthesis (3-dimensional [3D] mammography) technology with conventional (2-dimensional [2D]) mammography for breast cancer (BC) screening is the increased radiation dose from dual acquisitions. To resolve this problem, synthesized 2D (s2D) reconstruction images similar to 2D mammography were developed using tomosynthesis acquisitions. The present review summarizes the evidence for s2D versus digital mammography (2D) when using tomosynthesis (3D) for BC screening to address whether using s2D instead of 2D (alongside 3D) will yield similar detection measures. Comparative population screening studies have provided consistent evidence that cancer detection rates do not differ between integrated 2D/3D (range, 5.45-8.5/1000 screens) and s2D/3D (range, 5.03-8.8/1000 screens). Also, although the recall measures were relatively heterogeneous across included studies, little difference was found between the 2 modalities. The mean glandular dose for s2D/3D was 55% to 58% of that for 2D/3D. In the context of BC screening, s2D/3D involves substantially less radiation than 2D/3D and provides similar detection measures. Thus, consideration of transitioning to tomosynthesis screening should aim to use s2D/3D to minimize harm.
引用
收藏
页码:255 / +
页数:7
相关论文
共 50 条
  • [1] Digital breast tomosynthesis: a comparison of the accuracy of digital breast tomosynthesis, two-dimensional digital mammography and two-dimensional screening mammography (film-screen)
    MJ Michell
    RK Wasan
    P Whelehan
    A Iqbal
    CP Lawinski
    AN Donaldson
    DR Evans
    C Peacock
    ARM Wilson
    [J]. Breast Cancer Research, 11 (Suppl 2)
  • [2] Digital breast tomosynthesis: a comparison of the accuracy of digital breast tomosynthesis, two-dimensional digital mammography and two-dimensional screening mammography (film-screen)
    Michell, M. J.
    Wasan, R. K.
    Whelehan, P.
    Iqbal, A.
    Lawinski, C. P.
    Donaldson, A. N.
    Evans, D. R.
    Peacock, C.
    Wilson, A. R. M.
    [J]. BREAST CANCER RESEARCH, 2009, 11
  • [3] Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program
    Zuckerman, Samantha P.
    Conant, Emily F.
    Keller, Brad M.
    Maidment, Andrew D. A.
    Barufaldi, Bruno
    Weinstein, Susan P.
    Synnestvedt, Marie
    McDonald, Elizabeth S.
    [J]. RADIOLOGY, 2016, 281 (03) : 730 - 736
  • [4] Breast Cancer Detection: Digital Breast Tomosynthesis with Synthesized Mammography versus Digital Mammography
    Ha, Su Min
    Chang, Jung Min
    [J]. RADIOLOGY, 2023, 309 (03)
  • [5] Comparison of Digital Breast Tomosynthesis and Two-dimensional Mammography
    Korporaal, Johannes G.
    Mertelmeier, Thomas
    [J]. RADIOLOGY, 2016, 280 (03) : 980 - 981
  • [6] Three-dimensional tomosynthesis versus two-dimensional mammography in detection and characterization of different breast lesions
    Abdelattef, Samia Aboelnour Abdeltwab
    Ibrahim, Suzan Farouk
    Abdelhamid, Wafaa Raft
    Mahmoud, Fatten Mohamed
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [7] Three-dimensional tomosynthesis versus two-dimensional mammography in detection and characterization of different breast lesions
    Samia Aboelnour Abdeltwab Abdelattef
    Suzan Farouk Ibrahim
    Wafaa Raft Abdelhamid
    Fatten Mohamed Mahmoud
    [J]. Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [8] Comparison of Digital Breast Tomosynthesis and Two-dimensional Mammography Response
    Sharpe, Richard E., Jr.
    Mehta, Tejas
    Venkataraman, Shambhavi
    [J]. RADIOLOGY, 2016, 280 (03) : 981 - 981
  • [9] Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial
    Skaane, Per
    Bandos, Andriy L.
    Niklason, Loren T.
    Sebuodegard, Sofie
    Osteras, Bjorn H.
    Gullien, Randi
    Gur, David
    Hofvind, Solveig
    [J]. RADIOLOGY, 2019, 291 (01) : 22 - 29
  • [10] Clinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population
    Aujero, Mireille P.
    Gavenonis, Sara C.
    Benjamin, Ron
    Zhang, Zugui
    Holt, Jacqueline S.
    [J]. RADIOLOGY, 2017, 283 (01) : 70 - 76