Optimal sensor placement for active control of floor vibration considering spillover effect associated with modal filtering

被引:16
|
作者
Xue, Kai [1 ]
Igarashi, Akira [2 ]
Kachi, Takahiro [3 ]
机构
[1] Kyoto Univ, Dept Urban Management, Kyoto, Japan
[2] Kyoto Univ, Disaster Prevent Res Inst, Kyoto, Japan
[3] Sumitomo Riko Co Ltd, Nagoya, Aichi, Japan
关键词
Sensor placement; Plate vibration suppression; Modal filtering; Spillover effect; Active control; FLEXIBLE SYSTEMS;
D O I
10.1016/j.engstruct.2018.03.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Application of the modal filtering technique to active control can be effectively used to suppress vibration of floor panels by increasing the damping of the natural vibration modes involved. Limitation of this method is related to the spillover effect caused by the neglected modes. In this study, a sensor placement determination procedure is developed so that enhancement of the separation performance of the modeled modes and reduction of the spillover effect of the truncated modes in modal filtering are achieved at the same time by combining the minimum spillover method, effective independence method (EFI) and modal assurance criterion (MAC). Performance of the proposed procedure is investigated by conducting verification tests to control vibration of a rectangular steel plate with the modal filtering technique, and the sensor placement determined by the proposed approach achieves preferable results than other two sensor placement cases. The effectiveness of the proposed technique is also verified by state feedback control for individual modes. Using the proposed approach, effective active control of the steel plate vibration is successfully achieved.
引用
收藏
页码:198 / 209
页数:12
相关论文
共 50 条
  • [1] OPTIMAL SENSOR AND ACTUATOR PLACEMENT FOR ACTIVE VIBRATION CONTROL SYSTEMS
    Spaeh, Britta
    Schittenhelm, Rudolf Sebastian
    Rinderknecht, Stephan
    PROCEEDINGS OF THE ASME NOISE CONTROL AND ACOUSTICS DIVISION CONFERENCE (NCAD 2012), 2013, : 343 - 350
  • [2] Optimal placement of actuators and sensors for floor vibration control
    Hanagan, LM
    Kulasekere, EC
    Walgama, KS
    Premaratne, K
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (12): : 1380 - 1387
  • [3] Active vibration control of beams with optimal placement of piezoelectric sensor/actuator pairs
    Kumar, K. Ramesh
    Narayanan, S.
    SMART MATERIALS AND STRUCTURES, 2008, 17 (05)
  • [4] Optimal Actuator Placement for Constrained Gyroelastic Beam Considering Control Spillover
    Jia, Shiyuan
    Shan, Jinjun
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 2018, 41 (09) : 2073 - 2081
  • [5] Optimal placement of actuators and sensors for vibration active control
    Liu, FQ
    Zhang, LM
    Link, M
    IMAC - PROCEEDINGS OF THE 17TH INTERNATIONAL MODAL ANALYSIS CONFERENCE, VOLS I AND II, 1999, 3727 : 1820 - 1825
  • [6] Optimal Sensor Placement for Vibration Control of a Flexible Aircraft Wing
    He, Tianyi
    Zhu, Guoming G.
    Swei, Sean Shan-Min
    Su, Weihua
    2019 3RD IEEE CONFERENCE ON CONTROL TECHNOLOGY AND APPLICATIONS (IEEE CCTA 2019), 2019, : 755 - 760
  • [7] Optimal actuator placement for active vibration control of intelligent structure
    Zheng, B
    Yang, JF
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 2552 - 2555
  • [8] Experimental Investigation of Spillover Effect in System of Active Vibration Control
    Jovanovic, Miroslav M.
    Simonovic, Aleksandar M.
    Zoric, Nemanja D.
    Lukic, Nebojsa S.
    Stupar, Slobodan N.
    Petrovic, Ana S.
    Li, Wei
    FME TRANSACTIONS, 2014, 42 (04): : 329 - 334
  • [9] Optimal actuator placement for active vibration control with known disturbances
    Mirza, MA
    Van Niekerk, JL
    JOURNAL OF VIBRATION AND CONTROL, 1999, 5 (05) : 709 - 724
  • [10] ACTIVE VIBRATION CONTROL OF GYROELASTIC BODY WITH OPTIMAL PLACEMENT OF ACTUATORS
    Jia, Shiyuan
    Jia, Yinghong
    Xu, Shijie
    SPACEFLIGHT MECHANICS 2017, PTS I - IV, 2017, 160 : 3979 - 3992