A precision test of the isotropy of the speed of light using rotating cryogenic optical cavities

被引:0
|
作者
Schiller, S. [1 ]
Antonini, P. [1 ]
Okhapkin, M. [1 ]
机构
[1] Univ Dusseldorf, Inst Expt Phys, D-40225 Dusseldorf, Germany
关键词
D O I
10.1007/3-540-34523-X_14
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A test of Lorentz invariance for electromagnetic waves was performed by comparing the resonance frequencies of two stable optical resonators as a function of orientation in space. The crystalline resonators were operated at 3.4K in a cryostat employing a pulse-tube refrigerator. A new analysis yields the Robertson-Mansouri-Sexl theory parameter combination beta - delta - 1/2 = (-0.6 +/- 2.1 +/- 1.2) . 10(-10) and one parameter of the Standard Model Extension theory, (kappa(e-))(ZZ) = (-2.9 +/- 2.2). 10(-14).
引用
收藏
页码:401 / +
页数:3
相关论文
共 50 条
  • [1] A crossed optical cavities apparatus for a precision test of the isotropy of light propagation
    Eisele, Ch.
    Okhapkin, M.
    Nevsky, A. Yu.
    Schiller, S.
    [J]. OPTICS COMMUNICATIONS, 2008, 281 (05) : 1189 - 1196
  • [2] Testing Speed of Light Isotropy Using Rotating Cryogenic Sapphire Microwave Oscillators
    Parker, Stephen R.
    Nagel, Moritz
    Kovalchuk, Evgeny
    Stanwix, Paul L.
    Ivanov, Eugene N.
    Hartnett, John G.
    Peters, Achim
    Tobar, Michael E.
    [J]. 2014 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2014, : 457 - 457
  • [3] Comment on "Test of constancy of speed of light with rotating cryogenic optical resonators"
    Tobar, ME
    Wolf, P
    Stanwix, PL
    [J]. PHYSICAL REVIEW A, 2005, 72 (06):
  • [4] Test of the isotropy of the speed of light using a continuously rotating optical resonator -: art. no. 150401
    Herrmann, S
    Senger, A
    Kovalchuk, E
    Müller, H
    Peters, A
    [J]. PHYSICAL REVIEW LETTERS, 2005, 95 (15)
  • [5] Precision test of the isotropy of light propagation
    Müller, H
    Herrmann, S
    Braxmaier, C
    Schiller, S
    Peters, A
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 77 (08): : 719 - 731
  • [6] Precision test of the isotropy of light propagation
    H. Müller
    S. Herrmann
    C. Braxmaier
    S. Schiller
    A. Peters
    [J]. Applied Physics B, 2003, 77 : 719 - 731
  • [7] Test of constancy of speed of light with rotating cryogenic optical resonators -: art. no. 050101
    Antonini, P
    Okhapkin, M
    Göklü, E
    Schiller, S
    [J]. PHYSICAL REVIEW A, 2005, 71 (05):
  • [8] Reply to "Comment on 'test of constancy of speed of light with rotating cryogenic optical resonators' " -: art. no. 066102
    Antonini, P
    Okhapkin, M
    Göklü, E
    Schiller, S
    [J]. PHYSICAL REVIEW A, 2005, 72 (06):
  • [9] TEST OF SPATIAL ISOTROPY USING A CRYOGENIC TORSION PENDULUM
    PHILLIPS, PR
    [J]. PHYSICAL REVIEW LETTERS, 1987, 59 (15) : 1784 - 1787
  • [10] TEST OF THE ISOTROPY OF THE SPEED OF LIGHT USING FAST-BEAM LASER SPECTROSCOPY
    RIIS, E
    ANDERSEN, LUA
    BJERRE, N
    POULSEN, O
    LEE, SA
    HALL, JL
    [J]. PHYSICAL REVIEW LETTERS, 1988, 60 (02) : 81 - 84