Performance measurement of the scintillator with optical fiber detector for boron neutron capture therapy

被引:6
|
作者
Komeda, M. [1 ]
Kumada, H. [1 ]
Ishikawa, M. [2 ]
Nakamura, T. [1 ]
Yamamoto, K. [1 ]
Matsumura, A. [3 ]
机构
[1] Japan Atom Energy Agcy, Dept Res Reactor & Tandem Accelerator, Tokai, Ibaraki, Japan
[2] Hokkaido Univ Hosp, Dept Med Phys, Sapporo, Hokkaido, Japan
[3] Univ Tsukuba, Dept Neurosurg, Tsukuba, Ibaraki 305, Japan
关键词
SOF; Irradiation damage; Deterioration; Plastic scintillator; BNCT;
D O I
10.1016/j.apradiso.2009.03.083
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The thermal neutron flux can be easily measured in real time by using the scintillator with optical fiber (SOF) detector. However the irradiation damage under high-intensity neutron flux causes deterioration of the SOF detector due to radiation damage to the plastic scintillator in which (6)LiF is blended. After irradiating the SOF detector for 4 h (thermal neutron fluence is approximately 2.0 x 10(13) neutrons/cm(2)), the sensitivity of the SOF detector decreased by 3.0%. After irradiating the SOF detector for 2 months (thermal neutron fluence approximately 6.4 x 10(14) neutrons/cm(2)), the sensitivity was reduced to 42% of baseline. Supposing that the thermal neutron fluence is 2 x 10(12) neutrons/cm(2) on the surface of a patient in a BNCT treatment, the sensitivity of the SOF detector is reduced by approximately 0.3%. This report presents investigations on the deterioration of the SOF detector in irradiation experiments. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S254 / S257
页数:4
相关论文
共 50 条
  • [1] Development of an optical fiber type detector using a Eu:LiCaAlF6 scintillator for neutron monitoring in boron neutron capture therapy
    Watanabe, Kenichi
    Kawabata, Yuya
    Yamazaki, Atsushi
    Uritani, Akira
    Iguchi, Tetsuo
    Fukuda, Kentaro
    Yanagida, Takayuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 802 : 1 - 4
  • [2] Early clinical experience utilizing scintillator with optical fiber (SOF) detector in clinical boron neutron capture therapy: its issues and solutions
    Ishikawa, Masayori
    Yamamoto, Tetsuya
    Matsumura, Akira
    Hiratsuka, Junichi
    Miyatake, Shin-Ichi
    Kato, Itsuro
    Sakurai, Yoshinori
    Kumada, Hiroaki
    Shrestha, Shubhechha J.
    Ono, Koji
    RADIATION ONCOLOGY, 2016, 11
  • [3] Early clinical experience utilizing scintillator with optical fiber (SOF) detector in clinical boron neutron capture therapy: its issues and solutions
    Masayori Ishikawa
    Tetsuya Yamamoto
    Akira Matsumura
    Junichi Hiratsuka
    Shin-Ichi Miyatake
    Itsuro Kato
    Yoshinori Sakurai
    Hiroaki Kumada
    Shubhechha J. Shrestha
    Koji Ono
    Radiation Oncology, 11
  • [4] Testing of a fiber/scintillator neutron-capture detector
    Geist, WH
    Browne, MC
    Ensslin, N
    Mayo, DR
    Russo, PA
    Kusner, MR
    PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON FACILITY OPERATIONS-SAFEGUARDS INTERFACE, 1999, : 126 - 132
  • [5] Measurement of neutron and γ-ray intensity distributions with an optical fiber-scintillator detector
    Mori, C
    Uritani, A
    Miyahara, H
    Iguchi, T
    Shiroya, S
    Kobayashi, K
    Takada, E
    Fleming, RF
    Dewaraja, YK
    Stuenkel, D
    Knoll, GF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 129 - 132
  • [6] Development of real-time thermal neutron monitor using boron-loaded plastic scintillator with optical fiber for boron neutron capture therapy
    Ishikawa, M
    Ono, K
    Sakurai, Y
    Unesaki, H
    Uritani, A
    Bengua, G
    Kobayashi, T
    Tanaka, K
    Kosako, T
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 775 - 779
  • [7] A compact scintillator-based detector with collimator and shielding for dose monitoring in boron neutron capture therapy
    Caracciolo, Anita
    Ferri, Tommaso
    Borghi, Giacomo
    Carminati, Marco
    Protti, Nicoletta
    Altieri, Saverio
    Fiorini, Carlo
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [8] First optical observation of 10B-neutron capture reactions using a boron-added liquid scintillator for quality assurance in boron neutron capture therapy
    Akihiro Nohtomi
    Hideya Maeda
    Naoya Sakamoto
    Genichiro Wakabayashi
    Takushi Takata
    Yoshinori Sakurai
    Radiological Physics and Technology, 2022, 15 : 37 - 44
  • [9] First optical observation of 10B-neutron capture reactions using a boron-added liquid scintillator for quality assurance in boron neutron capture therapy
    Nohtomi, Akihiro
    Maeda, Hideya
    Sakamoto, Naoya
    Wakabayashi, Genichiro
    Takata, Takushi
    Sakurai, Yoshinori
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (01) : 37 - 44
  • [10] Feasibility study of optical imaging of the boron-dose distribution by a liquid scintillator in a clinical boron neutron capture therapy field
    Maeda, Hideya
    Nohtomi, Akihiro
    Hu, Naonori
    Kakino, Ryo
    Akita, Kazuhiko
    Ono, Koji
    MEDICAL PHYSICS, 2024, 51 (01) : 509 - 521