Liquid chromatographic tandem mass spectrometry method for the quantification of miglitol in human plasma

被引:1
|
作者
Nirogi, RVS
Kandikere, VN
Shukla, M
Mudigonda, K
Maurya, S
Boosi, R
Yerramilli, A
机构
[1] Suven Life Sci Ltd, Biopharmaceut Res, Hyderabad 500034, Andhra Pradesh, India
[2] Jawaharlal Nehru Univ, Inst Sci & Technol, Hyderabad, Andhra Pradesh, India
来源
ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH | 2006年 / 56卷 / 05期
关键词
alpha-glucosidase inhibitor; antidiabetic drugs; CAS; 72432-03-2; miglitol; human plasma; liquid chromatography/tandem mass spectrometry; pharmacokinetic study;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A rapid, sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of miglitol (CAS 72432-03-2), an alpha-glucosidase inhibitor, in human plasma using gabapentin (CAS 60142-96-3) as internal standard (IS). Following protein precipitation, the analytes were separated using an isocratic mobile phase on a reversed phase phenyl column and analyzed by NIS in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 208/146 for miglitol and m/z 172/154 for the IS. The assay exhibited a linear dynamic range of 1006000 ng/mL for miglitol in human plasma. The lower limit of quantification was 100 ng/mL with a relative standard deviation of less than 5%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. The average absolute recoveries of miglitol and the IS from spiked plasma samples were 40.5 +/- 2.7 and 47.1 +/- 2.9%, respectively. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacoldnetic, bioavailabitity or bioequivalence studies. The miglitol plasma concentration pro-file could be obtained for pharmacokinetic study. The observed maximum plasma concentration (C-max of miglitol (100 mg oral dose) is 1740 ng/mL, time to observed maximum plasma concentration (t(max)) is 3.5 h and elimination halflife (t(1/2)) is 2.5 h.
引用
收藏
页码:328 / 336
页数:9
相关论文
共 50 条
  • [1] Liquid chromatographic tandem mass spectrometry method for the quantification of Miglitol in human plasma
    Kandikere, Vishwottam N.
    Shukla, Manoj
    Mudigonda, Koteshwara
    Maurya, Santosh
    Boosi, Ravikumar
    Nirogi, Ramakrishna V. S.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [2] Determination of miglitol chromatography/tandem in human plasma by liquid mass spectrometry
    Li, Xin
    Wang, Yingwu
    Wang, Jiang
    Fawcett, J. Paul
    Zhao, Limei
    Gu, Jingkai
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (02) : 247 - 251
  • [3] Rapid validated liquid chromatographic method coupled with Tandem mass spectrometry for quantification of nintedanib in human plasma
    Darwish, Hany W.
    Attwa, Mohamed W.
    Kadi, Adnan A.
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2016, 15 (11) : 2467 - 2473
  • [4] Rapid Liquid Chromatographic – Tandem Mass Spectrometric Method for the Quantification of Pentoxifylline in Human Plasma
    N. V. S. Ramakrishna
    K. N. Vishwottam
    S. Manoj
    M. Koteshwara
    M. Santosh
    Y. Anjaneyulu
    Chromatographia, 2006, 63 : 135 - 141
  • [5] Rapid liquid chromatographic - Tandem mass spectrometric method for the quantification of pentoxifylline in human plasma
    Ramakrishna, NVS
    Vishwottaml, KN
    Manoj, S
    Koteshwara, M
    Santosh, M
    Anjaneyulu, Y
    CHROMATOGRAPHIA, 2006, 63 (3-4) : 135 - 141
  • [6] Liquid chromatographic - electrospray tandem mass spectrometric method for the quantification of nimodipine in human plasma
    Nirogi, R. V. S.
    Kandikere, V. N.
    Maurya, S.
    Mudigonda, K.
    Boosi, R.
    PHARMAZIE, 2006, 61 (10): : 828 - 834
  • [7] A new liquid chromatography/tandem mass spectrometry method for quantification of gangliosides in human plasma
    Huang, Qianyang
    Zhou, Xiang
    Liu, Danting
    Xin, Baozhong
    Cechner, Karen
    Wang, Heng
    Zhou, Aimin
    ANALYTICAL BIOCHEMISTRY, 2014, 455 : 26 - 34
  • [8] Liquid chromatography-tandem mass spectrometry method for the quantification of deglymidodrine in human plasma
    Jia, JY
    Liu, GY
    Li, SJ
    Li, XC
    Yuan, WF
    Yu, C
    Wang, YP
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (03) : 715 - 719
  • [9] Development and validation of a sensitive ultra-performance liquid chromatographic method with tandem mass spectrometry for quantification of doxorubicin in human plasma
    Semreen, Mohammad
    Al-niss, Hassan
    Mousa, Mouath
    El-Awady, Raafat
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [10] Quantification of alkylresorcinols in human plasma by liquid chromatography/tandem mass spectrometry
    Ross, Alastair B.
    Redeuil, Karine
    Vigo, Mario
    Rezzi, Serge
    Nagy, Kornel
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (05) : 554 - 560