Multi-channel pulse oximetry for wearable physiological monitoring

被引:0
|
作者
Mendelson, Y. [1 ]
Dao, D. K. [1 ]
Chon, K. H. [1 ]
机构
[1] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
关键词
Wearable sensors; pulse oximeter; motion artifacts; TRIAXIAL ACCELEROMETER; FOREHEAD; MOTION; PERFUSION; ACCURACY; EXERCISE; SIGNALS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pulse oximetry is a widely accepted clinical method for noninvasive monitoring of arterial oxygen saturation and pulse rate. Significant improvements aimed at curbing motion artifacts and improving reliability in detecting sufficiently strong photoplethysmographic signals are required to reduce errant measurements before the pulse oximeter can be considered for wider mobile applications. The present work describes the development of a wearable multi-channel reflectance pulse oximeter to investigate if a motion artifact-free signal can be obtained in at least one of the multi-channels at any given time. Pilot findings provided a proof of concept to support the hypothesis that photoplethysmograms acquired concurrently from independent channels in a multi-channel pulse oximeter sensor respond differently to motion artifacts, thus laying the foundation for future development of robust active noise cancellation and data fusion based algorithms to mitigate the effects of motion artifacts.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [1] Organic Multi-Channel Optoelectronic Sensors for Wearable Health Monitoring
    Khan, Yasser
    Han, Donggeon
    Ting, Jonathan
    Ahmed, Maruf
    Nagisetty, Ramune
    Arias, Ana C.
    IEEE ACCESS, 2019, 7 : 128114 - 128124
  • [2] An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry
    Haahr, Rasmus G.
    Duun, Sune B.
    Toft, Mette H.
    Belhage, Bo
    Larsen, Jan
    Birkelund, Karen
    Thomsen, Erik V.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2012, 6 (01) : 45 - 53
  • [3] A Portable Multi-Channel Behavioral State and Physiological Signal Monitoring System
    Young, Chung-Ping
    Chang, Da-Wei
    Liang, Sheng-Fu
    Shaw, Fu-Zen
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 2687 - 2691
  • [4] A Wireless Multi-Channel Physiological Signal Acquisition System-on-Chip for Wearable Devices
    Lee, Sheng-Cheng
    Lin, Yu -Shan
    Chen, Yu-Jui
    Chiueh, Herming
    2016 IEEE SENSORS, 2016,
  • [5] MULTI-CHANNEL PULSE HEIGHT ANALYSER
    PATWARDHAN, PK
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 1962, 21 (03): : 99 - &
  • [6] Multi-Channel Physiological Monitoring and Integration of Intelligence Prosthetic Arm Accessory System
    Liou, Jian-Chiun
    Su, Ting-Yu
    PROCEEDINGS OF 4TH IEEE INTERNATIONAL CONFERENCE ON APPLIED SYSTEM INNOVATION 2018 ( IEEE ICASI 2018 ), 2018, : 397 - 398
  • [7] A wearable reflectance pulse oximeter for remote physiological monitoring
    Mendelson, Y.
    Duckworth, R. J.
    Comtois, G.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2459 - +
  • [8] Development of a new wearable multi-channel sensing unit
    Naemura, K
    Hosaka, H
    Iseki, H
    Itao, K
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3874 - 3877
  • [9] VISUAL MONITORING OF MULTI-CHANNEL DISPLAYS
    GOULD, JD
    SCHAFFER, A
    IEEE TRANSACTIONS ON HUMAN FACTORS IN ELECTRONICS, 1966, HFE7 (02): : 69 - &
  • [10] AN APPLICATION OF AUTOSYNS TO MULTI-CHANNEL PHYSIOLOGICAL RECORDING
    BECKER, HC
    HODES, R
    FOUNDS, WL
    PEACOCK, SM
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1951, 76 (04): : 761 - 763