Operational performance of a cryogenic loop heat pipe with insufficient working fluid inventory

被引:23
|
作者
Mo, Qing [1 ]
Liang, Jingtao
机构
[1] Chinese Acad Sci, Cryogen Lab, Tech Inst Phys & Chem, POB 2711, Beijing 100080, Peoples R China
[2] Grad Univ Chinese Acad Sci, Beijing 100039, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
cryogenics; heat pipe; heat transfer; experiment;
D O I
10.1016/j.ijrefrig.2005.10.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
A cryogenic loop heat pipe (CLHP) has been developed for future aerospace applications at the Technical Institute of Physics and Chemistry (TIPC). It has been demonstrated that this CLHP, when placed horizontally, can operate in liquid-nitrogen temperature range and have a heat transfer capability of up to 12 W with proper working fluid inventory. This paper presents some particular characteristics of the CLHP when the compensation chamber is half-filled with liquid-phase working fluid before startup. The device has been tested at different orientations using nitrogen as the working fluid in order to compare its thermal behavior, specially related to the heat transfer capability, the operation temperature and the thermal resistance, as well as to investigate its operational characteristics under power level as low as I W. Tests were performed for the CLHP at horizontal position and with the liquid line 3.4 and 6.4 cm below the vapor line, respectively. The experimental results show the operationability of the CLHP tested at three orientations and tests with the liquid line 6.4 cm below the vapor line show lower operation temperatures and higher heat transfer capability. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:519 / 527
页数:9
相关论文
共 50 条
  • [1] Investigation on optimal working fluid inventory of a cryogenic loop heat pipe
    Yan, Tao
    Zhao, Ya-nan
    Liang, Jingtao
    Liu, Fulong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 66 : 334 - 337
  • [2] The influence of fluid inventory on the heat transfer performance of flat loop heat pipe
    Zhang, Wei
    Wang, Shuangfeng
    Lin, Zirong
    7TH INTERNATIONAL SYMPOSIUM ON MULTIPHASE FLOW, HEAT MASS TRANSFER AND ENERGY CONVERSION, 2013, 1547 : 522 - 530
  • [3] Working Fluid Inventory Effect on Heat Transfer Performance of a Grooved Micro Heat Pipe
    Li, Xibing
    Ma, Yunshi
    Wang, Xun
    Li, Ming
    ADVANCES IN MACHINING AND MANUFACTURING TECHNOLOGY XII, 2014, 589-590 : 559 - 564
  • [4] Experimental investigation of startup behaviors of a dual compensation chamber loop heat pipe with insufficient fluid inventory
    Bai, Lizhan
    Lin, Guiping
    Wen, Dongsheng
    Feng, Jianting
    APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1447 - 1456
  • [5] Distribution of heat flux by working fluid in loop heat pipe
    Nemec, Patrik
    Malcho, Milan
    EFM15 - EXPERIMENTAL FLUID MECHANICS 2015, 2016, 114
  • [6] EFFECT OF WORKING FLUID AND FILLING RATIO ON PERFORMANCE OF A CLOSED LOOP PULSATING HEAT PIPE
    Babu, E. R.
    Reddy, G. V. Gnanendra
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2016, 11 (06) : 872 - 880
  • [7] EFFECT OF SHROUD TEMPERATURE ON PERFORMANCE OF A CRYOGENIC LOOP HEAT PIPE
    Zhao, Ya'nan
    Yan, Tao
    Liang, Jingtao
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 409 - 416
  • [8] FRACTAL LOOP HEAT PIPE HEAT FLUX AND OPERATIONAL PERFORMANCE TESTING
    Silk, Eric A.
    Myre, David
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER, VOL 3, 2009, : 221 - 229
  • [9] Development of cryogenic loop heat pipe
    Karunanithi, R.
    Jacob, Subhash
    Narasimham, G. S. V. L.
    Nadig, D. S.
    Behera, Upendra
    Kumar, Dinesh
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 393 - +
  • [10] Supercritical startup strategy of cryogenic loop heat pipe with different working fluids
    Guo, Yuandong
    Lin, Guiping
    He, Jiang
    Zhang, Hongxing
    Miao, Jianyin
    Li, Jindong
    APPLIED THERMAL ENGINEERING, 2019, 155 : 267 - 276