ASSESSMENT OF AMBIENT NEUTRON DOSE EQUIVALENT IN SPATIALLY FRACTIONATED RADIOTHERAPY WITH PROTONS USING PHYSICAL COLLIMATORS

被引:5
|
作者
Charyyev, Serdar [1 ]
Wang, C-K Chris [2 ]
机构
[1] Emory Univ, Radiat Oncol & Winship Canc Inst, 1365 Clifton Rd NE, Atlanta, GA 30322 USA
[2] Georgia Inst Technol, Nucl & Radiol Engn, 770 State St NW, Atlanta, GA 30332 USA
关键词
RADIATION-THERAPY; MONTE-CARLO; EXPOSURES;
D O I
10.1093/rpd/ncaa030
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
New technique is trending in spatially fractionated radiotherapy with protons to utilize the spot scanning together with a physical collimator to obtain minibeams. The primary goal of this study is to quantify ambient neutron dose equivalent (H*(10)) due to the secondary neutrons when physical collimator is used to achieve desired minibeams. The H*(10) per treatment proton dose (D) was assessed using Monte Carlo code TOPAS and measured using WENDI-II detector at different angles (135, 180, 225 and 270 degrees) and distances (11 cm, 58 and 105 cm) from the phantom for two cases: with and without physical collimation. Without collimation H*(10)/D varied from 0.0013 to 0.242 mSv/Gy. With collimation H*(10)/D varied from 0.017 to 3.23 mSv/Gy. Results show that the secondary neutron dose will increase tenfold when the physical collimator is used. Regardless, it will be low and comparable to the neutron dose produced by conventional passive-scattered proton beams.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [1] An analytic model of neutron ambient dose equivalent and equivalent dose for proton radiotherapy
    Zhang, Rui
    Perez-Andujar, Angelica
    Fontenot, Jonas D.
    Taddei, Phillip J.
    Newhauser, Wayne D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23): : 6975 - 6985
  • [2] Equivalent Uniform Dose (EUD) and the Evaluation of Cell Survival in Spatially Fractionated Radiotherapy (SFRT)
    Bartzsch, S.
    Ahmed, M.
    Bicher, S.
    Stewart, R. D.
    Schmid, T. E.
    Combs, S. E.
    Meyer, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E642 - E642
  • [3] Tuning spatially fractionated radiotherapy dose profiles using the moiré effect
    Reaz, Fardous
    Traneus, Erik
    Bassler, Niels
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [4] Neutron conversion coefficients of ambient dose equivalent and personal dose equivalent
    Al Kanti, Hassan
    El Hajjaji, Otman
    El Bardouni, Tarek
    Mohammed, Maged
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (01): : 52 - 59
  • [5] EVALUATION OF NEUTRON AMBIENT DOSE EQUIVALENT IN CARBON-ION RADIOTHERAPY WITH ENERGY SCANNING
    Matsumoto, Shinnosuke
    Yonai, Shunsuke
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (03) : 310 - 318
  • [6] Secondary neutron ambient dose equivalent measurement of the wobbling system of a proton beam radiotherapy facility
    Liao, Ying-Lan
    Chen, Hsien-Hsin
    Chen, Hsin-Yu
    Huang, Hsiao-Chieh
    Yeh, Chien-Yi
    Tsai, Hui-Yu
    RADIATION PHYSICS AND CHEMISTRY, 2017, 137 : 116 - 120
  • [7] The Design of an Ambient Neutron Dose-Equivalent Meter
    Xia Wenming
    Jia Mingchun
    Guo Zhirong
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2011, 133 (08): : 84501 - 1
  • [8] Direction distribution of ambient neutron dose equivalent from 20 MeV protons incident on thick Be and Cu targets
    Sunil, C.
    Shanbhag, A. A.
    Nandy, M.
    Maiti, M.
    Bandyopadhyay, T.
    Sarkar, P. K.
    RADIATION PROTECTION DOSIMETRY, 2009, 136 (02) : 67 - 73
  • [9] Developing and using international standards for neutron ambient dose equivalent rate meters
    Voytchev, M.
    Radev, R.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 221
  • [10] Spatially fractionated radiotherapy (GRID) using helical tomotherapy
    Zhang, Xin
    Penagaricano, Jose
    Yan, Yulong
    Liang, Xiaoying
    Morrill, Steven
    Griffin, Robert J.
    Corry, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 396 - 407