A SIMPLE APPROACH FOR EVALUATING THE RECIPROCITY OF MATERIALS WITHOUT USING ANY CALIBRATION STANDARD

被引:7
|
作者
Hasar, U. C. [1 ,3 ]
Simsek, O. [2 ]
机构
[1] Ataturk Univ, Dept Elect & Elect Engn, TR-25240 Erzurum, Turkey
[2] Ataturk Univ, Dept Phys, TR-25240 Erzurum, Turkey
[3] SUNY Binghamton, Dept Elect & Comp Engn, Binghamton, NY 13902 USA
关键词
COMPLEX PERMITTIVITY DETERMINATION; TRANSMISSION-REFLECTION METHOD; INDEPENDENT METHOD;
D O I
10.2528/PIER09012905
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A simple approach for evaluation of the reciprocity of materials using raw scattering parameter measurements is proposed. This approach not only reduces the overall measurement time but also eliminates the need for calibrating the measurement system since it uses calibration-independent measurements. We have derived a metric function for reflecting and nonreflecting cells, which are used to house the sample under test. This function does not depend on electrical properties of materials and their lengths, and whether the cell is reflecting. We have also investigated the effects of the sample length and air pockets between sample external surfaces and cell inner walls on the performance of the evaluation of sample reciprocity.
引用
收藏
页码:139 / 152
页数:14
相关论文
共 50 条
  • [1] Novel approach of qNMR workflow by standardization using 2H integral: Application to any intrinsic calibration standard
    Monakhova, Yulia B.
    Diehl, Bernd W. K.
    TALANTA, 2021, 222
  • [2] Calibration of Photoemission Pyrometer without Using Standard Temperature Radiators
    K. A. Viazava
    K. N. Kasparov
    N. S. Miatselskaya
    O. G. Penyazkov
    Measurement Techniques, 2017, 60 : 578 - 582
  • [3] CALIBRATION OF PHOTOEMISSION PYROMETER WITHOUT USING STANDARD TEMPERATURE RADIATORS
    Viazava, K. A.
    Kasparov, K. N.
    Miatselskaya, N. S.
    Penyazkov, O. G.
    MEASUREMENT TECHNIQUES, 2017, 60 (06) : 578 - 582
  • [4] A simple linguistic approach to the Knobe effect, or the Knobe effect without any vignette
    Mizumoto, Masaharu
    PHILOSOPHICAL STUDIES, 2018, 175 (07) : 1613 - 1630
  • [5] A simple linguistic approach to the Knobe effect, or the Knobe effect without any vignette
    Masaharu Mizumoto
    Philosophical Studies, 2018, 175 : 1613 - 1630
  • [6] Simple determination of performance of explosives without using any experimental data
    Keshavarz, MH
    JOURNAL OF HAZARDOUS MATERIALS, 2005, 119 (1-3) : 25 - 29
  • [7] Simple calibration without metric information using an isoceles trapezoid
    Cao, XC
    Foroosh, H
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 1, 2004, : 104 - 107
  • [8] A simple approach to photoelastic calibration of glass using digital photoelasticity
    Ramesh, K.
    Vivek, R.
    Dora, P. Tarkes
    Sanyal, Dipayan
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2013, 378 : 7 - 14
  • [9] A simple approach for bioactive surface calibration using evanescent waves
    Marsh, Graham
    Waugh, Richard E.
    JOURNAL OF MICROSCOPY, 2016, 262 (03) : 245 - 251
  • [10] Unsupervised dynamic orthogonal projection. An efficient approach to calibration transfer without standard samples
    Diaz, Valeria Fonseca
    Roger, Jean-Michel
    Saeys, Wouter
    ANALYTICA CHIMICA ACTA, 2022, 1225