Sub-surface AFM imaging using tip generated stress and electric fields

被引:23
|
作者
Cadena, Maria J. [1 ,2 ]
Chen, Yuhang [3 ]
Reifenberger, Ronald G. [2 ,4 ]
Raman, Arvind [1 ,2 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Birck Nanotechnol Ctr, W Lafayette, IN 47907 USA
[3] Univ Sci & Technol China, Dept Precis Machinery & Precis Instrumentat, Hefei 230026, Anhui, Peoples R China
[4] Purdue Univ, Dept Phys, W Lafayette, IN 47907 USA
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
ATOMIC-FORCE MICROSCOPY;
D O I
10.1063/1.4977837
中图分类号
O59 [应用物理学];
学科分类号
摘要
It is well known that sub-surface nano-objects can be detected by Atomic Force Microscopy (AFM) with either sub-surface stress or electric fields, by using dynamic AFM methods such as Contact Resonance AFM (CR-AFM) or 2 nd -harmonic Kelvin Probe Force Microscopy (KPFM), respectively. However, little is understood regarding the relative differences between the two methods. We present a head-to-head comparison between the sub-surface imaging capabilities of these two methods through experiments and computational models based on finite element analysis (FEA). High resolution subsurface images are obtained using both techniques, from the same area of a polymer composite film containing single-walled carbon nanotube networks embedded in a polyimide matrix. The results are used to interpret quantitatively the observables from CR-AFM and KPFM, with a particular focus on the depth sensitivity and lateral resolution. The depth of the buried carbon nanotube bundles estimated by combining experiments and FEA is found to be in good agreement between the two methods. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Sub-surface imaging of carbon nanotube-polymer composites using dynamic AFM methods
    Cadena, Maria J.
    Misiego, Rocio
    Smith, Kyle C.
    Avila, Alba
    Pipes, Byron
    Reifenberger, Ron
    Raman, Arvind
    NANOTECHNOLOGY, 2013, 24 (13)
  • [2] Volumetric sub-surface imaging using spectrally encoded endoscopy
    Yelin, D.
    Bouma, B. E.
    Tearney, G. J.
    OPTICS EXPRESS, 2008, 16 (03) : 1748 - 1757
  • [3] Evaluation of sub-surface stresses using thermoelastic stress analysis
    Sathon, N.
    Dulieu-Barton, J. M.
    ADVANCES IN EXPERIMENTAL MECHANICS V, 2007, 7-8 : 153 - +
  • [4] Sub-surface imaging by scanning thermal microscopy
    Hammiche, A
    Pollock, HM
    Song, M
    Hourston, DJ
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (02) : 142 - 150
  • [5] Nondestructive Sub-surface Microwave Imaging of Biomaterials
    Kazemi, Fatemeh
    Mohanna, Farahnaz
    Ahmadi-Shokouh, Javad
    2016 24TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2016, : 1383 - 1387
  • [6] Polarization based imaging of sub-surface tissue
    Sudha, GF
    Palanivelu, TG
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2004, 42 (12) : 902 - 907
  • [7] Sub-surface imaging by scanning thermal microscopy
    Hammiche, A.
    Pollock, H.M.
    Hourston, D.J.
    Measurement Science & Technology, 1996, 7 (02):
  • [8] Combined sub-surface imaging and surface spectroscopic imaging in biological samples
    Zuluaga, AF
    Chang, SK
    Richards-Kortum, R
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 114 - 116
  • [9] Detecting sub-surface cracking in laminated membranes using infrared imaging
    Mackin, TJ
    Vernon, PJ
    POLYMER COMPOSITES, 2001, 22 (06) : 752 - 761
  • [10] Effect of sub-surface hydrogen on intrinsic crack tip plasticity in aluminium
    Wang, Y.
    Connetable, D.
    Tanguy, D.
    PHILOSOPHICAL MAGAZINE, 2019, 99 (19) : 2355 - 2375