Delays and errors in cardiopulmonary resuscitation and defibrillation by pediatric residents during simulated cardiopulmonary arrests

被引:107
|
作者
Hunt, Elizabeth A. [1 ,2 ,3 ]
Vera, Kimberly [4 ]
Diener-West, Marie [5 ]
Haggerty, Jamie A. [3 ]
Nelson, Kristen L. [1 ,2 ,3 ]
Shaffner, Donald H. [1 ,2 ]
Pronovost, Peter J. [1 ,3 ,6 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Anesthesiol & Crit Care Med, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Sch Med, Dept Pediat, Baltimore, MD 21205 USA
[3] Johns Hopkins Med Simulat Ctr, Baltimore, MD 21206 USA
[4] Vanderbilt Univ, Sch Med, Dept Pediat, Nashville, TN 37212 USA
[5] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biostat, Baltimore, MD USA
[6] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Hlth Policy & Management, Baltimore, MD USA
关键词
Cardiopulmonary arrest; Cardiopulmonary resuscitation (CPR); Defibrillation; Pediatrics; Education; Graduate medical education; Patient simulation; Time; HOSPITAL CARDIAC-ARREST; VENTRICULAR-FIBRILLATION; PRECORDIAL COMPRESSION; MANUAL DEFIBRILLATION; CHEST COMPRESSIONS; QUALITY; PROBABILITY; SUCCESS; SKILLS; TIME;
D O I
10.1016/j.resuscitation.2009.03.020
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The quality of life support delivered during cardiopulmonary resuscitation affects outcomes. However, little data exist regarding the quality of resuscitation delivered to children and factors associated with adherence to American Heart Association (ANA) resuscitation guidelines. Participants: Pediatric residents from an academic, tertiary care hospital. Design: Prospective, observational cohort study of residents trained in the AHA PALS 2000 guidelines managing a high-fidelity mannequin simulator programmed to develop pulseless ventricular tachycardia (PVT). Main outcome measures: Proportion of residents who: (1) started compressions in <= 1 min from onset of PVT, (2) defibrillated in <= 3 min and (3) factors associated with time to defibrillation. Results: Seventy of eighty (88%) residents participated. Forty-six of seventy (66%) failed to start compressions within 1 min of pulselessness and 23/70 (33%) never started compressions. Only 38/70 (54%) residents defibrillated the mannequin in <= 3 min of onset of PVT. There was no significant difference in time elapsed between onset of PVT and defibrillation by level of post-graduate training. However, residents who had previously discharged a defibrillator on either a patient or a simulator compared to those who had not were 87% more likely to successfully defibrillate the mannequin at any point in time (hazard ratio 1.87, 95% CI: 1.08-3.21, p = 0.02). Conclusions: Pediatric residents do not meet performance standards set by the AHA. Future curricula should focus training on identified defects including: (1) equal emphasis on "airway and breathing" and "circulation" and (2) hands-on training with using and discharging a defibrillator in order to improve safety and outcomes. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:819 / 825
页数:7
相关论文
共 50 条
  • [1] Cognitive Aids Do Not Prompt Initiation of Cardiopulmonary Resuscitation in Simulated Pediatric Cardiopulmonary Arrests
    McMillan, Kristen Nelson
    Rosen, Michael A.
    Shilkofski, Nicole A.
    Bradshaw, Jamie Haggerty
    Saliski, Mary
    Hunt, Elizabeth A.
    SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2018, 13 (01): : 41 - 46
  • [2] The Use of Cognitive Aids During Simulated Pediatric Cardiopulmonary Arrests
    Nelson, Kristen L.
    Shilkofski, Nicole A.
    Haggerty, Jamie A.
    Saliski, Mary
    Hunt, Elizabeth A.
    SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2008, 3 (03): : 138 - 145
  • [3] Delays to performance of resuscitation maneuvers in simulated pediatric cardiopulmonary arrest.
    Hunt, Elizabeth A.
    Shilkofski, Nicole A.
    Vera, Kimberly
    Nelson, Kristen L.
    CRITICAL CARE MEDICINE, 2006, 34 (12) : A14 - A14
  • [4] Cardiopulmonary Resuscitation during Simulated Pediatric Interhospital Ambulance Transport
    Noje, Corina
    Duval-Arnould, Jordan
    Perretta, Julianne
    Costabile, Philomena M.
    Henderson, Eric
    Shilkofski, Nicole A.
    Hunt, Elizabeth A.
    PEDIATRICS, 2018, 142
  • [5] Cardiopulmonary resuscitation algorithms, defibrillation and optimized ventilation during resuscitation
    Samson, Ricardo A.
    Berg, Marc D.
    Berg, Robert A.
    CURRENT OPINION IN ANESTHESIOLOGY, 2006, 19 (02) : 146 - 156
  • [6] CARDIOPULMONARY-RESUSCITATION AND DEFIBRILLATION
    EISENBERG, M
    WESTERN JOURNAL OF MEDICINE, 1987, 146 (05): : 608 - 609
  • [7] The impact of manual defibrillation technique on no-flow time during simulated cardiopulmonary resuscitation
    Perkins, Gavin D.
    Davies, Robin P.
    Soar, Jasmeet
    Thickett, David R.
    RESUSCITATION, 2007, 73 (01) : 109 - 114
  • [8] Influence of Cardiopulmonary Resuscitation Coaching and Provider Role on Perception of Cardiopulmonary Resuscitation Quality During Simulated Pediatric Cardiac Arrest
    Cheng, Adam
    Kessler, David
    Lin, Yiqun
    Tofil, Nancy M.
    Hunt, Elizabeth A.
    Davidson, Jennifer
    Chatfield, Jenny
    Duff, Jonathan P.
    Brown, Linda
    Nye, Megan
    Gaither, Stacy
    Collier, Holly
    MacKinnon, Laura
    Lowe, Katherine
    Lambert, Viktoriya
    PEDIATRIC CRITICAL CARE MEDICINE, 2019, 20 (04) : E191 - E198
  • [9] Immediate Defibrillation or Defibrillation After Cardiopulmonary Resuscitation
    Koike, Soichi
    Tanabe, Seizan
    Ogawa, Toshio
    Akahane, Manabu
    Yasunaga, Hideo
    Horiguchi, Hiromasa
    Matsumoto, Shinya
    Imamura, Tomoaki
    PREHOSPITAL EMERGENCY CARE, 2011, 15 (03) : 393 - 400
  • [10] Human factors affect the quality of cardiopulmonary resuscitation in simulated cardiac arrests
    Marsch, SCU
    Müller, C
    Marquardt, K
    Conrad, G
    Tschan, F
    Hunziker, PR
    RESUSCITATION, 2004, 60 (01) : 51 - 56