Transcatheter and ministernotomy aortic valve replacement after bioprosthetic valve failure

被引:0
|
作者
Shah, Vishal N. [1 ,2 ,3 ]
Buckley, Meghan [1 ]
Orlov, Oleg, I [1 ,2 ]
Imperato, Nicholas S. [1 ]
Sicouri, Serge [1 ]
Goldman, Scott M. [2 ,3 ]
Plestis, Konstadinos A. [4 ]
机构
[1] Lankenau Inst Med Res, Wynnewood, PA USA
[2] Lankenau Heart Inst, Dept Cardiothorac Surg, Wynnewood, PA 19096 USA
[3] Lankenau Heart Inst, Struct Heart Dis Program, Wynnewood, PA 19096 USA
[4] Thomas Jefferson Univ Hosp, Dept Cardiac Surg, Philadelphia, PA USA
关键词
bioprosthetic valves; ministernotomy; reoperation; transcatheter valve in valve; IN-VALVE; IMPLANTATION; STERNOTOMY; SURGERY;
D O I
10.1111/jocs.15225
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transcatheter valve-in-valve implantation (TViV) and minimally invasive reoperative aortic valve replacement (MIrAVR) have rapidly increased as alternatives to conventional reoperative surgical AVR. This study reports a single-center experience of patients undergoing TViV and MIrAVR after bioprosthetic valve failure. Methods In this retrospective review between March 2009 and October 2018, 68 patients without reoperative full sternotomies, concomitant procedures, active endocarditis, and prior homografts or coronary artery bypass grafting underwent isolated AVR for degenerated aortic bioprostheses. Society of Thoracic Surgeons (STS) risk scores and age are reported as median (interquartile range [IQR]) and length of stay is reported as mean (standard deviation [SD]) due to their characteristics of the distribution. Results Forty-one (60.3%) patients underwent TViV, and 27 (39.7%) patients underwent MIrAVR. Median [IQR] STS risk scores were 5.7 [4.0-7.8] and 2.0 [1.5-3.4] for TViV and MIrAVR, respectively (p <= .001). The median [IQR] age for TViV patients was higher (78 [71-84] vs. 66 [53-72] years, p <= 0.001). More permanent pacemakers were implanted (22.2% vs. 9.8%) following MIrAVR. The MIrAVR group had a higher rate of atrial fibrillation (18.5% vs. 9.8%, p = .466). Average (SD) length of stay was less in TViV (5.3 days, SD: 3.4 vs. 8.6 days, SD: 7.4, p = .001). Survival at 1 year was not significantly different for TViV and MIrAVR (94.9% [95% confidence interval [CI]: 81.0%, 98.7%] and 86.9% [95% CI: 64.0%, 95.7%], respectively [p = .969]). Conclusions Despite being at higher-risk, patients undergoing TViV had reduced rates of permanent pacemaker implantations and atrial fibrillation, and a shorter hospital stay as compared to MIrAVR. Survival at 1-year was similar between the two groups.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 50 条
  • [1] Transcatheter Aortic Valve Replacement for Bioprosthetic Aortic Valve Failure The Valve-in-Valve Procedure
    Webb, John G.
    Dvir, Danny
    [J]. CIRCULATION, 2013, 127 (25) : 2542 - 2550
  • [2] Transcatheter Aortic Valve Replacement for Aortic Bioprosthetic Valve Failure With Cardiogenic Shock
    Fudim, Marat
    Markley, Roshanak R.
    Robbins, Mark A.
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (11): : 625 - 626
  • [3] PERI-VALVE THROMBUS AFTER VALVE IN VALVE TRANSCATHETER AORTIC VALVE REPLACEMENT FOR BIOPROSTHETIC AORTIC VALVE STENOSIS
    Patel, Apurva
    Dadu, Razvan
    Chamsi-Pasha, Mohammed
    Mahmarian, John
    Shah, Alpesh
    Reul, Ross
    Reardon, Michael
    Kleiman, Neal
    Barker, Colin
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 2536 - 2536
  • [4] Predictors of Elevated Gradients After Transcatheter Aortic Valve Replacement for Failing Bioprosthetic Aortic Valve Replacement
    Richmond, Robert L.
    O'Hair, Daniel P.
    Harland, Daniel R.
    Bajwa, Tanvir
    Allaqaband, Suhail Q.
    Kirby, Amanda M.
    Olet, Susan
    Khandheria, Bijoy K.
    Jain, Renuka
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B137 - B137
  • [5] Incidence of Long-Term Structural Valve Dysfunction and Bioprosthetic Valve Failure After Transcatheter Aortic Valve Replacement
    Barbanti, Marco
    Costa, Giuliano
    Zappulla, Paolo
    Todaro, Denise
    Picci, Andrea
    Rapisarda, Giulia
    Di Simone, Emanuela
    Sicuso, Rita
    Buccheri, Sergio
    Gulino, Simona
    Pilato, Gerlando
    La Spina, Ketty
    D'Arrigo, Paolo
    Valvo, Roberto
    Indelicato, Antonino
    Giannazzo, Daniela
    Imme, Sebastiano
    Tamburino, Claudia
    Patane, Martina
    Sgroi, Carmelo
    Giuffrida, Angelo
    Trovato, Danilo
    Monte, Ines Paola
    Deste, Wanda
    Capranzano, Piera
    Capodanno, Davide
    Tamburino, Corrado
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (15):
  • [6] Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement
    Chakravarty, Tarun
    Patel, Akshar
    Kapadia, Samir
    Raschpichler, Matthias
    Smalling, Richard W.
    Szeto, Wilson Y.
    Abramowitz, Yigal
    Cheng, Wen
    Douglas, Pamela S.
    Hahn, Rebecca T.
    Herrmann, Howard C.
    Kereiakes, Dean
    Svensson, Lars
    Yoon, Sung-Han
    Babaliaros, Vasilis C.
    Kodali, Susheel
    Thourani, Vinod H.
    Alu, Maria C.
    Liu, Yangbo
    McAndrew, Thomas
    Mack, Michael
    Leon, Martin B.
    Makkar, Raj R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (09) : 1190 - 1200
  • [7] Valve-in-Valve Transcatheter Aortic Valve Replacement in Failed Trifecta Bioprosthetic Aortic Valve
    Zmaili, Mohammad
    Spilias, Nikolaos
    Ramu, Shivabalan Kathavarayan
    Prasad, Rohan
    Abushouk, Abdelrahman
    Harb, Serge
    Puri, Rishi
    Reed, Grant
    Yun, James
    Krishnaswamy, Amar
    Kapadia, Samir
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B285 - B286
  • [8] Bioprosthetic Valves for Transcatheter Aortic Valve Replacement
    Reardon, Michael J.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (08): : 844 - 845
  • [9] Valve-in-valve Transcatheter Aortic Valve Replacement in a Patient with Late Failure of a Bioprosthetic Bentall Procedure
    Budassi, Simone
    Verheye, Stefan
    Agostoni, Pierfrancesco
    Zivelonghi, Carlo
    Scott, Benjamin
    Vermeersch, Paul
    [J]. STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2020, 4 (03): : 236 - 239
  • [10] BIOPROSTHETIC VALVE FRACTURE TECHNIQUE FOR VALVE-IN-VALVE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Lahsaei, Saba
    Bhat, Tariq
    Agrawal, Harsh
    Afari, Maxwell
    Khan, M. Faisal
    Carrozza, Joseph
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 2323 - 2323