Photoacoustic Tomography with a Ring Ultrasound Transducer: A Comparison of Different Illumination Strategies

被引:17
|
作者
Alijabbari, Naser [1 ]
Alshahrani, Suhail S. [1 ]
Pattyn, Alexander [1 ]
Mehrmohammadi, Mohammad [1 ,2 ,3 ]
机构
[1] Wayne State Univ, Dept Biomed Engn, Detroit, MI 48201 USA
[2] Wayne State Univ, Dept Elect & Comp Engn, Detroit, MI 48201 USA
[3] Barbara Ann Karmanos Canc Inst, Detroit, MI 48201 USA
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 15期
关键词
full-ring illumination; diffused-beam illumination; point source illumination; ultrasound tomography (UST); photoacoustic tomography (PAT); BREAST ULTRASOUND; CANCER; MAMMOGRAPHY; RISK; WOMEN; MRI;
D O I
10.3390/app9153094
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application Biological diagnostic applications based on endogenous or exogenous chromophores and early breast cancer detection in dense tissue. Abstract Photoacoustic (PA) imaging is a methodology that uses the absorption of short laser pulses by endogenous or exogenous chromophores within human tissue, and the subsequent generation of acoustic waves acquired by an ultrasound (US) transducer, to form an image that can provide functional and molecular information. Amongst the various types of PA imaging, PA tomography (PAT) has been proposed for imaging pathologies such as breast cancer. However, the main challenge for PAT imaging is the deliverance of sufficient light energy horizontally through an imaging cross-section as well as vertically. In this study, three different illumination methods are compared for a full-ring ultrasound (US) PAT system. The three distinct illumination setups are full-ring, diffused-beam, and point source illumination. The full-ring system utilizes a cone mirror and parabolic reflector to create the ringed-shaped beam for PAT, while the diffuse scheme uses a light diffuser to expand the beam, which illuminates tissue-mimicking phantoms. The results indicate that the full-ring illumination is capable of providing a more uniform fluence irrespective of the vertical depth of the imaged cross-section, while the point source and diffused illumination methods provide a higher fluence at regions closer to the point of entry, which diminishes with depth. In addition, a set of experiments was conducted to determine the optimum position of ring-illumination with respect to the position of the acoustic detectors to achieve the highest signal-to-noise ratio.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Ring Ultrasound Transducer based Miniaturized Photoacoustic Imaging System
    Dangi, Ajay
    Agrawal, Sumit
    Lieberknecht, Jedidiah
    Zhang, Jason
    Kothapalli, Sri-Rajasekhar
    2018 IEEE SENSORS, 2018, : 772 - 775
  • [2] All-reflective ring illumination system for photoacoustic tomography
    Alshahrani, Suhail Salem
    Yan, Yan
    Alijabbari, Naser
    Pattyn, Alexander
    Avrutsky, Ivan
    Malyarenko, Eugene
    Poudel, Joemini
    Anastasio, Mark
    Mehrmohammadi, Mohammad
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (04)
  • [3] The effectiveness of the omnidirectional illumination in full-ring photoacoustic tomography
    Alshahrani, Suhail
    Pattyn, Alexander
    Alijabbari, Naser
    Yan, Yan
    Anastasio, Mark
    Mehrmohammadi, Mohammad
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [4] MOPA fiber laser for photoacoustic tomography using arrayed ultrasound transducer
    Lee, Yong-Jae
    Ahn, Jun-Tae
    Sim, Joo Yong
    Kim, Bong Kyu
    Jeon, Min Yong
    Lee, Byeong Ha
    23RD OPTO-ELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC2018), 2018,
  • [5] Photoacoustic tomography based on a novel linear array ultrasound transducer configuration
    Lin, Xiangwei
    Leng, Guanji
    Shen, Yi
    Wang, Yan
    Zhang, Miao
    Sun, Mingjian
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 399 - 403
  • [6] Slip-ring-based multi-transducer photoacoustic tomography system
    Deng, Zijian
    Li, Wenzhao
    Li, Changhui
    OPTICS LETTERS, 2016, 41 (12) : 2859 - 2862
  • [7] Image plane adjustment in photoacoustic tomography based on a full ring transducer array
    Ji, Zhong
    Ding, Wenzheng
    2016 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2016,
  • [8] Practical review on photoacoustic computed tomography using curved ultrasound array transducer
    Yang, Jinge
    Choi, Seongwook
    Kim, Chulhong
    BIOMEDICAL ENGINEERING LETTERS, 2022, 12 (01) : 19 - 35
  • [9] Practical review on photoacoustic computed tomography using curved ultrasound array transducer
    Jinge Yang
    Seongwook Choi
    Chulhong Kim
    Biomedical Engineering Letters, 2022, 12 : 19 - 35
  • [10] Performance comparison of high-speed photoacoustic microscopy: opto-ultrasound combiner versus ring-shaped ultrasound transducer
    Kim, Hyojin
    Kim, Jin Young
    Cho, Seonghee
    Ahn, Joongho
    Kim, Yeonggeun
    Kim, Hyungham
    Kim, Chulhong
    BIOMEDICAL ENGINEERING LETTERS, 2022, 12 (02) : 147 - 153