Cable-Shared Dual-Frequency Catheter for Intravascular Ultrasound

被引:19
|
作者
Su, Min [1 ,2 ]
Zhang, Zhiqiang [1 ,2 ]
Hong, Jiehan [1 ,2 ,3 ]
Huang, Yaocai [1 ,2 ,3 ]
Mu, Peitian [1 ,2 ,3 ]
Yu, Yanyan [1 ,2 ]
Liu, Rong [1 ,2 ]
Liang, Suzi [1 ,2 ,3 ]
Zheng, Hairong [1 ,2 ,3 ]
Qiu, Weibao [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Shenzhen Key Lab Ultrasound Imaging & Therapy, Shenzhen 518055, Peoples R China
[3] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Peoples R China
基金
美国国家科学基金会; 中国博士后科学基金;
关键词
Cable-shared transducer; deep penetration; dual frequency; high-imaging resolution; intravascular ultrasound; TRANSDUCER; RESOLUTION; DESIGN; SYSTEM; ARRAY; IVUS;
D O I
10.1109/TUFFC.2019.2898256
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study proposes a catheter consisting of dual-frequency transducer for intravascular ultrasound. Both ultrasonic elements with different frequencies were connected to one coaxial cable to make the connection simple. The aperture sizes of the ultrasound elements were 0.4 x 0.6 and 0.3 x 0.4 mm 2 for the low-frequency element and high-frequency element, respectively. The center frequency and bandwidth of the fabricated low-frequency transducer were 33.8 MHz and 49.3%, respectively. Meanwhile, the center frequency and bandwidth of the high-frequency transducer were 80.6 MHz and 50.3%, respectively. Imaging evaluations of wire phantom, tissue phantom, and vessel tissue demonstrated good imaging capability of the dual-frequency catheter. The spatial resolutions are 19 mu m axially and 128 mu m laterally for the high-frequency transducer, and 37 mu m axially and 199 mu m laterally for the low-frequency transducer. Bandpass filters were designed to separate the mixed echo signals. After filtering, the images from different ultrasound elements can be successfully identified, indicating the feasibility of the proposed cable-shared dual-frequency imaging strategy. The proposed method has simple structure, good imaging resolution, and large penetration depth, showing good application prospect for intravascular ultrasound.
引用
收藏
页码:849 / 856
页数:8
相关论文
共 50 条
  • [1] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, ME
    Goertz, DE
    Vos, HJ
    Droog, E
    Blacquière, G
    Gisolf, A
    van der Steen, AFW
    [J]. 2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 241 - 244
  • [2] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, Martijn E.
    Goertz, David E.
    Vos, Hendrik J.
    Tesselaar, Erik
    Blacquiere, Gerrit
    Gisolf, Andries
    Krams, Rob
    van der Steen, Antonius F. W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (11): : 1649 - 1654
  • [3] DEVELOPMENT OF A 3 FRENCH DUAL-FREQUENCY INTRAVASCULAR ULTRASOUND CATHETER
    Munding, Chelsea E.
    Cherin, Emmanuel
    Jourard, Isaac
    Weyers, Jill J.
    Goertz, David E.
    Courtney, Brian K.
    Foster, F. Stuart
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (01): : 251 - 266
  • [4] Intravascular Dual-frequency Ultrasound Transducer Using a Stack Composite
    Wu, Huaiyu
    Kim, Howuk
    Zhang, Bohua
    Kim, Jinwook
    Dayton, Paul
    Xu, Zhen
    Jiang, Xiaoning
    [J]. INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [5] A novel dual-frequency imaging method for intravascular ultrasound applications
    Qiu, Weibao
    Chen, Yan
    Wong, Chi-Man
    Liu, Baoqiang
    Dai, Jiyan
    Zheng, Hairong
    [J]. ULTRASONICS, 2015, 57 : 31 - 35
  • [6] A Backing-Layer-Shared Miniature Dual-Frequency Ultrasound Probe for Intravascular Ultrasound Imaging: In Vitro and Ex Vivo Validations
    He, Yashuo
    Liu, Xi
    Zhang, Jiayi
    Peng, Chang
    [J]. BIOSENSORS-BASEL, 2023, 13 (11):
  • [7] Dual-frequency intravascular ultrasound imaging: A novel approach to plaque vulnerability
    Hashimoto, G
    Hiro, T
    Fujii, T
    Okamura, T
    Yamada, J
    Fukumoto, Y
    Kanou, H
    Matsuzaki, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 120A - 121A
  • [8] Dual-frequency IVUS array for contrast enhanced intravascular ultrasound imaging
    Wang, Zhuochen
    Huang, Wenbin
    Jiang, Xiaoning
    Martin, K. Heath
    Dayton, Paul A.
    [J]. 2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [9] An array transmitter for dual-frequency contrast enhanced intravascular ultrasound imaging
    Wang, Zhuochen
    Ma, Jianguo
    Jiang, Xiaoning
    Martin, Karl Heath
    Dayton, Paul A.
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2104 - 2107
  • [10] Dual-Frequency Intravascular Sonothrombolysis: An In Vitro Study
    Wu, Huaiyu
    Goel, Leela D.
    Kim, Howuk
    Zhang, Bohua
    Kim, Jinwook
    Dayton, Paul A.
    Xu, Zhen
    Jiang, Xiaoning
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (12) : 3599 - 3607