Determination of Halogenated Flame Retardants Using Gas Chromatography with Atmospheric Pressure Chemical Ionization (APCI) and a High-Resolution Quadrupole Time-of-Flight Mass Spectrometer (HRqTOFMS)

被引:35
|
作者
Megson, David [1 ,2 ]
Robson, Matthew [3 ,4 ]
Jobst, Karl J. [4 ]
Helm, Paul A. [4 ]
Reiner, Eric J. [1 ,4 ]
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
[2] Manchester Metropolitan Univ, Sch Sci & Environm, Manchester M1 5GD, Lancs, England
[3] Brock Univ, Dept Chem, St Catharines, ON L2S 3A1, Canada
[4] Ontario Minist Environm & Climate Change, Toronto, ON M9P 3V6, Canada
关键词
HOUSE-DUST; 1,2,5,6-TETRABROMOCYCLOOCTANE TBCO; THERMAL STABILITIES; DETECTION SYSTEM; DIPHENYL ETHERS; INDOOR DUST; 1,2-DIBROMO-4-(1,2-DIBROMOETHYL)CYCLOHEXANE; SEDIMENT; ISOMERS; DIOXINS;
D O I
10.1021/acs.analchem.6b01550
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method to determine halogenated flame retardants was developed that utilizes gas chromatography with atmospheric chemical ionization (APCI) high-resolution quadrupole time-of-flight mass spectrometry (HRqTOFMS). The new GC-APCI-HRqTOFMS method was used to determine the presence of 65 halogenated flame retardants (HFRs) in the United Sates National Institute of Standards and Technology (NIST) organic contaminants in house dust standard reference material (SRM). The accuracy of the measurements was compared to the certified NIST value for polybrominated diphenyl ethers (PBDEs) and had an average accuracy for the 14 certified PBDEs of 109% with subpicogram detection limits (on column) from a single 1 mu L injection with a run time of 18 min. SRM2585 extracts were also analyzed by GC electron ionization (EI) high-resolution mass spectrometry (HRMS), and there was an excellent correlation between the two data sets (R-2 value of 0.996). The presence of 25 additional HFRs were also screened in the dust standard, and 10 were detected in concentrations above the limits of detection; these were p-TBX, PBBZ, PBT, PBEB, TDCPP, HBBZ, EHTBB, TBBPA, BEHTBP, and BTBPE. The results presented show that the proposed APCI-HRqTOFMS method was comparable and in many cases an improvement on the existing EI-HRMS method.
引用
收藏
页码:11406 / 11411
页数:6
相关论文
共 50 条
  • [1] Enhanced metabolite profiling using a redesigned atmospheric pressure chemical ionization source for gas chromatography coupled to high-resolution time-of-flight mass spectrometry
    Christian J. Wachsmuth
    Thomas A. Hahn
    Peter J. Oefner
    Katja Dettmer
    Analytical and Bioanalytical Chemistry, 2015, 407 : 6669 - 6680
  • [2] Enhanced metabolite profiling using a redesigned atmospheric pressure chemical ionization source for gas chromatography coupled to high-resolution time-of-flight mass spectrometry
    Wachsmuth, Christian J.
    Hahn, Thomas A.
    Oefner, Peter J.
    Dettmer, Katja
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (22) : 6669 - 6680
  • [3] Determination of stimulants using gas chromatography/high-resolution time-of-flight mass spectrometry and a soft ionization source
    Lopez-Avila, Viorica
    Cooley, James
    Urdahl, Randall
    Thevis, Mario
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (23) : 2714 - 2724
  • [4] Simultaneous determination of 21 organophosphorus flame retardants in rice by gas chromatography quadrupole time-of-flight mass spectrometry
    Yang, Jishuang
    Zhou, Xia
    Li, Xiuqin
    Li, Xiaomin
    Gao, Yan
    Zhang, Qinghe
    TALANTA, 2023, 253
  • [5] Analysis of brominated flame retardants and their derivatives by atmospheric pressure chemical ionization using gas chromatography coupled to tandem quadrupole mass spectrometry
    Geng, Dawei
    Kukucka, Petr
    Jogsten, Ingrid Ericson
    TALANTA, 2017, 162 : 618 - 624
  • [6] A HIGH-RESOLUTION TIME-OF-FLIGHT MASS-SPECTROMETER USING LASER RESONANCE IONIZATION
    FREY, R
    WEISS, G
    KAMINSKI, H
    SCHLAG, EW
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1985, 40 (12): : 1349 - 1350
  • [7] High-resolution multi-reflection time-of-flight mass spectrometer with atmospheric pressure interface
    Yan, Shuxiong
    Ren, Yi
    Huang, Qi
    Hong, Yi
    Chen, Zhengge
    Li, Mei
    Hu, Bin
    Huang, Zhengxu
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (11)
  • [8] Analyses of the brominated vegetable oil in soft drinks using gas chromatography-flame ionization detector and atmospheric pressure gas chromatography-quadrupole/time-of-flight mass spectrometry
    Iwakoshi, Keiko
    Ogawa, Asamoe
    Iwakoshi, Katsushi
    Nakajima, Jyunichi
    Kobayashi, Chigusa
    Sasamoto, Takeo
    FOOD CHEMISTRY, 2021, 338
  • [9] HIGH-RESOLUTION TIME-OF-FLIGHT MASS-SPECTROMETER
    BERGMANN, T
    MARTIN, TP
    SCHABER, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (04): : 792 - 793
  • [10] Differentiation of underivatized monosaccharides by atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry
    Zhu, Zhenqian
    Song, Liguo
    Bartmess, John E.