Non-destructive Detection and Screening of Non-uniformity in Microwave Sterilization Using Hyperspectral Imaging Analysis

被引:80
|
作者
Pan, Yuanyuan [1 ,2 ,3 ]
Sun, Da-Wen [1 ,2 ,3 ,4 ]
Cheng, Jun-Hu [1 ,2 ,3 ]
Han, Zhong [1 ,2 ,3 ]
机构
[1] South China Univ Technol, Sch Food Sci & Engn, Guangzhou 510641, Guangdong, Peoples R China
[2] South China Univ Technol, Guangzhou Higher Educ Mega Ctr, Acad Contemporary Food Engn, Guangzhou 510006, Guangdong, Peoples R China
[3] Guangzhou Higher Educ Mega Ctr, Engn & Technol Res Ctr Guangdong Prov Intelligent, Guangzhou 510006, Guangdong, Peoples R China
[4] Natl Univ Ireland, Univ Coll Dublin, FRCFT, Agr & Food Sci Ctr, Dublin 4, Ireland
基金
中国博士后科学基金;
关键词
Hyperspectral imaging; Infrared thermal camera; Microwave sterilization; Non-uniformity; LEAST-SQUARES REGRESSION; COMPUTER VISION; HEATING UNIFORMITY; MOISTURE-CONTENT; LISTERIA-MONOCYTOGENES; CHEMOMETRIC ANALYSIS; FEATURE WAVELENGTHS; MICROBIAL SPOILAGE; VARIABLE SELECTION; CHEMICAL SPOILAGE;
D O I
10.1007/s12161-017-1134-5
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The non-uniformity of microwave sterilization usually causes incomplete inactivation of microorganism (especially foodborne pathogens) and potential food safety issue. Detecting the non-uniformity of load distribution using hyperspectral imaging (HSI) (400-1050 nm) in tandem with multivariate analysis was investigated and infrared (IR) thermal imaging technique was used to assist the evaluation. The best simplified model of least-squares support vector machines (LS-SVM) obtained based on ten optimal wavelengths showed an R-p(2) of 0.905, RMSEP of 0.404 log CFU/mL and RPD of 2.62, while the analysis of temperatures detected by IR thermal camera showed that the temperatures of mid-way along each edge were obviously higher than the center, and heating time of microwave had a significant effect on mean temperature (p < 0.01) and temperature coefficient of variation (COV) values (p < 0.01). Moreover, the visualization of L. monocytogenes load distribution was acquired by transferring the quantitative model of LS-SVM to each pixel in the image at different heating times, with the results being well consistent with those of temperature distribution by IR thermal camera. Therefore HSI technique could be used to monitor the non-uniformity of microwave sterilization processing.
引用
收藏
页码:1568 / 1580
页数:13
相关论文
共 50 条
  • [1] Non-destructive Detection and Screening of Non-uniformity in Microwave Sterilization Using Hyperspectral Imaging Analysis
    Yuanyuan Pan
    Da-Wen Sun
    Jun-Hu Cheng
    Zhong Han
    Food Analytical Methods, 2018, 11 : 1568 - 1580
  • [2] Hyperspectral imaging for non-destructive detection of honey adulteration
    Shao, Yuanyuan
    Shi, Yukang
    Xuan, Guantao
    Li, Quankai
    Wang, Fuhui
    Shi, Chengkun
    Hu, Zhichao
    VIBRATIONAL SPECTROSCOPY, 2022, 118
  • [3] Non-destructive detection of moisture content in gherkin using hyperspectral imaging
    Li, Dan, 1600, Chinese Society of Astronautics (43):
  • [4] Non-destructive Detection of Hollow Heart in Potatoes Using Hyperspectral Imaging
    Dacal-Nieto, Angel
    Formella, Arno
    Carrion, Pilar
    Vazquez-Fernandez, Esteban
    Fernandez-Delgado, Manuel
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS: 14TH INTERNATIONAL CONFERENCE, CAIP 2011, PT 2, 2011, 6855 : 180 - 187
  • [5] Hyperspectral imaging: Potential in non-destructive analysis of palimpsests
    Rapantzikos, K
    Balas, C
    2005 International Conference on Image Processing (ICIP), Vols 1-5, 2005, : 1813 - 1816
  • [6] Non-destructive detection of egg qualities based on hyperspectral imaging
    Yao, Kunshan
    Sun, Jun
    Chen, Chen
    Xu, Min
    Zhou, Xin
    Cao, Yan
    Tian, Yan
    JOURNAL OF FOOD ENGINEERING, 2022, 325
  • [7] Non-destructive detection of protein content in mulberry leaves by using hyperspectral imaging
    Li, Xunlan
    Peng, Fangfang
    Wei, Zhaoxin
    Han, Guohui
    Liu, Jianfei
    FRONTIERS IN PLANT SCIENCE, 2023, 14
  • [8] Using Hyperspectral Imaging as a Non-Destructive Method to Discern Artworks
    Zheng, Jonathan
    Manzano, Carlos
    Unnikrishnakurup, Sreedhar
    Kumar, Vinod
    Ngo, Andrew
    e-Journal of Nondestructive Testing, 2022, 27 (12):
  • [9] Identification of Cold Spots Using Non-Destructive Hyperspectral Imaging Technology in Model Food Processed by Coaxially Induced Microwave Pasteurization and Sterilization
    Soni, Aswathi
    Al-Sarayreh, Mahmoud
    Reis, Marlon M.
    Smith, Jeremy
    Tong, Kris
    Brightwell, Gale
    FOODS, 2020, 9 (06)
  • [10] Non-Destructive Trace Detection of Explosives Using Pushbroom Scanning Hyperspectral Imaging System
    Chaudhary, Siddharth
    Ninsawat, Sarawut
    Nakamura, Tai
    SENSORS, 2019, 19 (01)