Aortic atheroma is related to number of particulates captured by intro-aortic filtration in CABG

被引:14
|
作者
Bergman, P
Hadjinikolaou, L
van der Linden, J [1 ]
机构
[1] Huddinge Univ Hosp, Karolinska Inst, Dept Cardiothorac Surg, SE-14186 Stockholm, Sweden
[2] Huddinge Univ Hosp, Karolinska Inst, Dept Anesthesiol, SE-14186 Stockholm, Sweden
[3] Glenfield Univ Hosp, Dept Cardiothorac Surg, Leicester, Leics, England
关键词
intraaortic filtration; stroke; atherosclerosis; cardiopulmonary bypass; coronary artery bypass surgery;
D O I
10.1016/S1010-7940(02)00430-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Intra-aortic filtration during coronary artery bypass grafting (CABG) has the potential to harvest all particles embolized into the aorta proximal to the filter. The aim of this study was to determine risk factors for embolization of particles during CABG.Methods: Forty consecutive patients undergoing conventional multi-vessel CABG were included in the study. Plaques of the ascending aorta were determined by epiaortic ultrasonography prior to aortic manipulation. Intra-aortic filters (Embol-X, Mountain View, CA) were inserted before removal of the aortic cross-clamp and extracted after end of cardiopulmonary bypass. Filters underwent histologic analysis at a core lab (Stanford University, Stanford, CA). Results: The average number of proximal anastomoses was 2.2 (SD 0.55, range 1-3). All patients had particles in the filters. The average number of particles per filter was 10.5 (SD 5.4, range 2-23) with a mean surface area of 8.1 mm(2) (SD 9.3, range 0.3-51.1). Fibrous atheroma was extracted from 85% (34/40) of the filters. Logistic regression explained 46% (r(2) = 0.46, P < 0.001) of the number of particles harvested by the filters. The most important independent risk factors for particles were number/grade of atheromas in the ascending aorta (P < 0.01), obesity (P < 0.02), hypertension (P < 0.02) and number of proximal anastomoses (P < 0.02). Conclusions: Atheroma in the ascending aorta is the most important risk factor for particle embolization during CABG. The number of particles correlated with the extent of atheromatous disease in the ascending aorta and logistic regression identified hypertension, obesity and the number of proximal anastomoses to have significant influence on the number of captured particulates. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:539 / 544
页数:6
相关论文
共 10 条
  • [1] Aortic atheroma is related to outcome but not numbers of emboli during coronary bypass
    Barbut, D
    Lo, YW
    Hartman, GS
    Yao, FSF
    Trifiletti, RR
    Hager, DN
    Hinton, RB
    Gold, JP
    Isom, OW
    ANNALS OF THORACIC SURGERY, 1997, 64 (02): : 454 - 459
  • [2] Reduction of neurologic complications by intra-aortic filtration in patients undergoing combined intracardiac and CABG procedures
    Wimmer-Greinecker, G
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (02) : 159 - 163
  • [3] HYPERREACTIVITY OF AORTIC SMOOTH-MUSCLE TO SEROTONIN IS RELATED TO THE PRESENCE OF ATHEROMA IN WATANABE HERITABLE HYPERLIPEMIC RABBITS
    TAGAWA, H
    TOMOIKE, H
    MITSUOKA, W
    SATOH, S
    KUGA, T
    SHIMOKAWA, H
    NAKAMURA, M
    TAKESHITA, A
    CARDIOVASCULAR RESEARCH, 1993, 27 (12) : 2164 - 2169
  • [4] The Number of Preoperative Abdominal False Lumen-perfused Small Branches Is Related to Abdominal Aortic Remodeling after Thoracic Endovascular Aortic Repair for Type B Aortic Dissection
    Ge, Yangyang
    Lv, Xiaomeng
    Ge, Xiaohu
    Miao, Jianhang
    Fan, Weidong
    Rong, Dan
    Guo, Wei
    ANNALS OF VASCULAR SURGERY, 2021, 71 : 56 - 64
  • [5] Reduction of neurologic complications by intra-aortic filtration in patients undergoing combined intracardiac and CABG procedures - Appendix B. Conference discussion
    de Vivie, R
    Wimmer-Greinecker
    Pirk, J
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (02) : 164 - 164
  • [6] HIGHER NUMBER OF SPONTANEOUS RUPTURED AORTIC PLAQUES AND INJURIES MAY BE RELATED TO PERIPHERAL ARTERY DISEASE
    Komatsu, Sei
    Takahashi, Satoru
    Takewa, Mitsuhiko
    Ohara, Tomoki
    Yutani, Chikao
    Kodama, Kazuhisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 2106 - 2106
  • [7] Possible intra-aortic ballon pump "function-related" mechanism of embolic events in patient with protruding atheroma in the thoracic aorta
    Mysore, S
    Kotsis, VN
    Galanos, O
    Connery, CP
    Drossos, G
    Hillel, Z
    Anagnostopoulos, CE
    JOURNAL OF CARDIOVASCULAR SURGERY, 2001, 42 (02): : 207 - 210
  • [8] Copy number variation analysis in bicuspid aortic valve-related aortopathy identifies TBX20 as a contributing gene
    Luyckx, Ilse
    Kumar, Ajay A.
    Reyniers, Edwin
    Dekeyser, Emily
    Vanderstraeten, Kathleen
    Vandeweyer, Geert
    Wunnemann, Florian
    Preuss, Christoph
    Mazzella, Jean-Michael
    Goudot, Guillaume
    Messas, Emmanuel
    Albuisson, Juliette
    Jeunemaitre, Xavier
    Eriksson, Per
    Mohamed, Salah A.
    Kempers, Marlies
    Salemink, Simone
    Duijnhouwer, Anthonie
    Andelfinger, Gregor
    Dietz, Harry C.
    Verstraeten, Aline
    Van Laer, Lut
    Loeys, Bart L.
    Zhurayev, Rustam
    Zerbino, Dmytro
    Mital, Seema
    Mertens, Luc
    Franco-Cereceda, Anders
    Verhagen, Judith M. A.
    van de Laar, Ingrid M. B. H.
    Wessels, Marja W.
    Nemcikova, Michaela
    Krebsova, Alice
    EUROPEAN JOURNAL OF HUMAN GENETICS, 2019, 27 (07) : 1033 - 1043
  • [9] Copy number variation analysis in bicuspid aortic valve-related aortopathy identifies TBX20 as a contributing gene
    Ilse Luyckx
    Ajay A. Kumar
    Edwin Reyniers
    Emily Dekeyser
    Kathleen Vanderstraeten
    Geert Vandeweyer
    Florian Wünnemann
    Christoph Preuss
    Jean-Michaël Mazzella
    Guillaume Goudot
    Emmanuel Messas
    Juliette Albuisson
    Xavier Jeunemaitre
    Per Eriksson
    Salah A. Mohamed
    Marlies Kempers
    Simone Salemink
    Anthonie Duijnhouwer
    Gregor Andelfinger
    Harry C Dietz
    Aline Verstraeten
    Lut Van Laer
    Bart L. Loeys
    European Journal of Human Genetics, 2019, 27 : 1033 - 1043
  • [10] Paradoxical Low-flow Low-gradient Aortic Stenosis: Improvement in Indexed Stroke Volume After Trans-catheter Aortic Valve Replacement is Inversely Related to the Number of Conditions Contributing to Low Transvalvular Flow
    Hosadurg, Nisha
    Huang, Dou
    Brown, Kristen
    Weintraub, Andrew R.
    Patel, Ayan R.
    Wessler, Benjamin S.
    CIRCULATION, 2019, 140