Loop-mediated isothermal amplification for the detection of SARS-CoV-2 in saliva

被引:32
|
作者
Janikova, Monika [1 ]
Hodosy, Julius [1 ,2 ]
Boor, Peter [3 ]
Klempa, Boris [4 ]
Celec, Peter [1 ,5 ,6 ]
机构
[1] Comenius Univ, Inst Mol Biomed, Fac Med, Bratislava, Slovakia
[2] Univ Hosp, Bratislava, Slovakia
[3] Univ Clin RWTH, Dept Nephrol, Inst Pathol, Aachen, Germany
[4] Slovak Acad Sci, Inst Virol, Biomed Res Ctr, Bratislava, Slovakia
[5] Comenius Univ, Inst Pathophysiol, Fac Med, Bratislava, Slovakia
[6] Comenius Univ, Dept Mol Biol, Fac Nat Sci, Bratislava, Slovakia
来源
MICROBIAL BIOTECHNOLOGY | 2021年 / 14卷 / 01期
关键词
RIBONUCLEASE; LAMP;
D O I
10.1111/1751-7915.13737
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In the fight against the recent COVID-19 pandemics, testing is crucial. Nasopharyngeal swabs and real-time RT-PCR are used for the detection of the viral RNA. The collection of saliva is non-invasive, pain-free and does not require trained personnel. An alternative to RT-PCR is loop-mediated isothermal amplification coupled with reverse transcription (RT-LAMP) that is easy to perform, quick and does not require a thermal cycler. The aim of this study was to test whether SARS-CoV-2 RNA can be detected directly in saliva using RT-LAMP. We have tested 16 primer mixes from the available literature in three rounds of sensitivity assays. The selected RT-LAMP primer mix has a limit of detection of 6 copies of viral RNA per reaction in comparison with RT-PCR with 1 copy per reaction. Whole saliva, as well as saliva collected using Salivette collection tubes, interfered with the RT-LAMP analysis. Neither Chelex-100 nor protease treatment of saliva prevented the inhibitory effect of saliva. With the addition of the ribonuclease inhibitor, the sensitivity of the RT-LAMP assay was 12 copies per reaction of RNA in Salivette (R) saliva samples and 6 copies per reaction of RNA in whole saliva samples. This study shows that it is possible to combine the use of saliva and RT-LAMP for SARS-CoV-2 RNA detection without RNA extraction which was confirmed on a small set of correctly diagnosed clinical samples. Further studies should prove whether this protocol is suitable for point of care testing in the clinical setting.
引用
收藏
页码:307 / 316
页数:10
相关论文
共 50 条
  • [1] Rapid visual detection of SARS-CoV-2 by colorimetric loop-mediated isothermal amplification
    Reynes, Barbara
    Serra, Francisca
    Palou, Andreu
    [J]. BIOTECHNIQUES, 2021, 70 (04) : 218 - 225
  • [2] SARS-CoV-2 detection by fluorescence loop-mediated isothermal amplification with and without RNA extraction
    Taki, Keisuke
    Yokota, Isao
    Fukumoto, Tatsuya
    Iwasaki, Sumio
    Fujisawa, Shinichi
    Takahashi, Masayoshi
    Negishi, Saeki
    Hayasaka, Kasumi
    Sato, Kaori
    Oguri, Satoshi
    Nishida, Mutsumi
    Sugita, Junichi
    Konno, Satoshi
    Saito, Tomoya
    Teshima, Takanori
    [J]. JOURNAL OF INFECTION AND CHEMOTHERAPY, 2021, 27 (02) : 410 - 412
  • [3] Colorimetric reverse transcriptional loop-mediated isothermal amplification for rapid detection of SARS-CoV-2
    Rai, P.
    Anupama, K. P.
    Pai, A. P.
    Prerana, S.
    Prajna, V. S.
    Ballamoole, K. K.
    Maiti, B.
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2022, 116 : S36 - S36
  • [4] Development of an Electrochemical Sensor for SARS-CoV-2 Detection Based on Loop-Mediated Isothermal Amplification
    Rivas-Macho, Ane
    Eletxigerra, Unai
    Diez-Ahedo, Ruth
    Barros, Angela
    Merino, Santos
    Goni-de-Cerio, Felipe
    Olabarria, Garbine
    [J]. BIOSENSORS-BASEL, 2023, 13 (10):
  • [5] A Novel Reverse Transcription Loop-Mediated Isothermal Amplification Method for Rapid Detection of SARS-CoV-2
    Lu, Renfei
    Wu, Xiuming
    Wan, Zhenzhou
    Li, Yingxue
    Jin, Xia
    Zhang, Chiyu
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (08)
  • [6] A loop-mediated isothermal amplification-enabled analytical assay for the detection of SARS-CoV-2: A review
    Li, Mingna
    Ge, Hongjuan
    Sun, Zhe
    Fu, Jangshan
    Cao, Lele
    Feng, Xinrui
    Meng, Guixian
    Peng, Yubo
    Liu, Yan
    Zhao, Chen
    [J]. FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [7] Comparative evaluation of 19 reverse transcription loop-mediated isothermal amplification assays for detection of SARS-CoV-2
    Dong, Yajuan
    Wu, Xiuming
    Li, Shenwei
    Lu, Renfei
    Li, Yingxue
    Wan, Zhenzhou
    Qin, Jianru
    Yu, Guoying
    Jin, Xia
    Zhang, Chiyu
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] Comparative evaluation of 19 reverse transcription loop-mediated isothermal amplification assays for detection of SARS-CoV-2
    Yajuan Dong
    Xiuming Wu
    Shenwei Li
    Renfei Lu
    Yingxue Li
    Zhenzhou Wan
    Jianru Qin
    Guoying Yu
    Xia Jin
    Chiyu Zhang
    [J]. Scientific Reports, 11
  • [9] Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Ultrasensitive Detection of SARS-CoV-2 in Saliva and Viral Transport Medium Clinical Samples
    Ganguli, Anurup
    Mostafa, Ariana
    Berger, Jacob
    Lim, Jongwon
    Araud, Elbashir
    Baek, Janice
    de Ramirez, Sarah A. Stewart
    Baltaji, Ali
    Roth, Kelly
    Aamir, Muhammad
    Aedma, Surya
    Mady, Mohamed
    Mahajan, Pranav
    Sathe, Sanjivani
    Johnson, Mark
    White, Karen
    Kumar, James
    Valera, Enrique
    Bashir, Rashid
    [J]. ANALYTICAL CHEMISTRY, 2021, 93 (22) : 7797 - 7807
  • [10] Rapid and Extraction-Free Detection of SARS-CoV-2 from Saliva by Colorimetric Reverse-Transcription Loop-Mediated Isothermal Amplification
    Lalli, Matthew A.
    Langmade, S. Joshua
    Chen, Xuhua
    Fronick, Catrina C.
    Sawyer, Christopher S.
    Burcea, Lauren C.
    Wilkinson, Michael N.
    Fulton, Robert S.
    Heinz, Michael
    Buchser, William J.
    Head, Richard D.
    Mitra, Robi D.
    Milbrandt, Jeffrey
    [J]. CLINICAL CHEMISTRY, 2021, 67 (02) : 415 - 424