Experience with a fluorescence-based beam position monitor at the APS

被引:0
|
作者
Dufresne, EM [1 ]
Guzman, JA [1 ]
Dierker, SB [1 ]
Clarke, R [1 ]
Arms, DA [1 ]
Walko, DA [1 ]
机构
[1] Univ Michigan, Dept Phys, Ann Arbor, MI 48109 USA
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have recently redesigned the first crystal mount of our cryogenically cooled monochromator to reduce its sensitivity to pressure fluctuations in the cryogenic lines feeding the Si (111) crystal. With the use of a fluorescence-based X-ray beam position monitor (BPM) placed 19 m away from the monochromator, much operational experience has been gained on the sensitivity of the beam position and intensity to small changes in the cooling system. In this presentation, we will describe our X-ray BPM design and performance and will provide examples of changes that have made the beam position more stable on our bean-dine. One such change for example has been the top-up operation of the Advanced Photon Source (APS), which has reduced the thermal drifts associated with the ring current decay.
引用
收藏
页码:679 / 682
页数:4
相关论文
共 50 条
  • [1] New beam position monitor system design for the APS injector
    Lill, R
    Singh, O
    Arnold, N
    [J]. BEAM INSTRUMENTATION WORKSHOP 2002, 2002, 648 : 401 - 408
  • [2] Test beam results of a fluorescence-based monitor for ultra-high dose rates
    Trigilio, A.
    De Gregorio, A.
    De Simoni, M.
    Franciosini, G.
    Garbini, M.
    Magi, M.
    Marafini, M.
    Mirabelli, R.
    Muscato, A.
    Patera, V.
    Schiavi, A.
    Toppi, M.
    Traini, G.
    Sarti, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2024, 19 (02)
  • [3] COMPARISON OF FLUORESCENCE-BASED REACTIONS TO MONITOR LIPID VESICLE LYSIS AND OR FUSION
    KENDALL, DA
    MACDONALD, RC
    [J]. BIOPHYSICAL JOURNAL, 1983, 41 (02) : A361 - A361
  • [4] Development of a hard X-ray beam position monitor for insertion device beams at the APS
    Decker, Glenn
    Rosenbaum, Gerd
    Singh, Om
    [J]. BEAM INSTRUMENTATION WORKSHOP 2006, 2006, 868 : 202 - +
  • [5] Insertion Site Performance Differences for a Fluorescence-Based Continuous Glucose Monitor
    Chen, Xiaoxiao
    Wang, Xiaolin
    Rajaraman, Srinivasan
    Dehennis, Andrew
    Whitehurst, Todd
    [J]. DIABETES, 2013, 62 : A45 - A45
  • [6] Beam based measurement of beam position monitor electrode gains
    Rubin, D. L.
    Billing, M.
    Meller, R.
    Palmer, M.
    Rendina, M.
    Rider, N.
    Sagan, D.
    Shanks, J.
    Strohman, C.
    [J]. PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2010, 13 (09):
  • [7] FLUORESCENCE-BASED METHOD TO MONITOR LIPID LATERAL DISTRIBUTIONS IN LIPID BILAYERS
    SILVIUS, JR
    [J]. BIOPHYSICAL JOURNAL, 1990, 57 (02) : A467 - A467
  • [8] A fluorescence-based assay to monitor transcriptional activity of NFAT in living cells
    Rinne, Andreas
    Blatter, Lothar A.
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2010, 588 (17): : 3211 - 3216
  • [9] THE APS X-RAY UNDULATOR PHOTON-BEAM POSITION MONITOR AND TESTS AT CHESS AND NSLS
    SHU, D
    RODRICKS, B
    BARRAZA, J
    SANCHEZ, T
    KUZAY, TM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 319 (1-3): : 56 - 62
  • [10] Operational experience with the photon beam position monitor for undulator beamlines of Elettra
    Galimberti, A
    Borghes, R
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 584 - 587