A reusable, custom-made warming blanket prevents core hypothermia during major neonatal surgery

被引:0
|
作者
Kongsayreepong, S [1 ]
Gunnaleka, P
Suraseranivongse, S
Pirayavaraporn, S
Chowvanayotin, S
Montapaneewat, T
Manon, C
机构
[1] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Anesthesiol, Bangkok 10700, Thailand
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Surg Nursing, Bangkok 10700, Thailand
关键词
D O I
10.1007/BF03017389
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: To introduce a reusable model of neonatal forced air warming blanket for intraoperative use during major noncardiac neonatal surgery and to determine clinical efficacy of this reusable blanket compared with the commonly used disposable blankets. Methods: Delivered air temperature and calorie uptake of standard thermal bodies within the reusable blankets, Bair Hugger(R) blanket model 530 and model 555 were studied. Also, an efficacy study was conducted in 90 neonatal patients scheduled for major noncardiac surgery comparing the reusable blanket, the Bair Hugger(R) blanket model 530 and passive heat conservation as a control. The covered reusable blanket was used as a rescue procedure if the core temperature was < 35.5degreesC. Results: Delivered air temperature and heat transfer from the covered reusable blanket did not differ significantly from those of the Bair Hugger(R) blanket. model 530 and model 555 (despite 0.75degreesC-1.2degreesC of heat trapped under the sheet and 1.3 Kcal less energy transfer). Temperatures measured underneath patients (correlated to poorly perfused areas) were highest using the Bair Hugger(R) blanket model 555. The reusable blanket was efficacious in preventing intraoperative core hypothermia and not different from the Bair Hugger(R) blanket model 530. About 1/13 of the patients in the control group had presented a core temperature < 35.5degreesC but were successfully rescued using the reusable blanket. No adverse events were associated with any of these warming methods. Conclusion: This study shows the clinical efficacy of our reusable blanket for the prevention of core hypothermia during major neonatal surgery, which is not different from commonly used disposable blankets.
引用
收藏
页码:605 / 609
页数:5
相关论文
共 12 条
  • [1] A reusable, custom-made warming blanket prevents core hypothermia during major neonatal surgeryUne couverture chauffante réutilisable, faite sur mesure, prévient l’hypothermie centrale pendant une intervention chirurgicale néonatale importante
    Suneerat Kongsayreepong
    Panidaporn Gunnaleka
    Suwannee Suraseranivongse
    Sangsom Pirayavaraporn
    Sumitra Chowvanayotin
    Thunyanit Montapaneewat
    Chitprapa Manon
    [J]. Canadian Journal of Anesthesia, 2002, 49 (6): : 605 - 609
  • [2] A custom-made forced-air warming mattress for heat loss prevention during vascular surgery: clinical evaluation
    Suraseranivongse, Suwannee
    Pongraweewan, Orawan
    Kongmuang, Benjawan
    Tivirach, Wannapa
    Pornboonseram, Suchart
    [J]. ASIAN BIOMEDICINE, 2009, 3 (03) : 299 - 307
  • [3] LEG WARMING MINIMIZES CORE HYPOTHERMIA DURING ABDOMINAL-SURGERY
    CAMUS, Y
    DELVA, E
    JUST, B
    LIENHART, A
    [J]. ANESTHESIA AND ANALGESIA, 1993, 77 (05): : 995 - 999
  • [4] Delayed forced air warming prevents hypothermia during abdominal aortic surgery
    Karayan, J
    Thomas, D
    Lacoste, L
    Dhoste, K
    Ricco, JB
    Fusciardi, J
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (03) : 459 - 460
  • [6] Warming of intravenous fluids prevents hypothermia during off-pump coronary artery bypass graft surgery
    Jeong, Sung-Moon
    Hahm, Kyung-Don
    Jeong, Yong-Bo
    Yang, Hong-Seuk
    Choi, In-Cheol
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (01) : 67 - 70
  • [7] Warming before and after epidural block before general anaesthesia for major abdominal surgery prevents perioperative hypothermia A randomised controlled trial
    Horn, Ernst-Peter
    Bein, Berthold
    Broch, Ole
    Iden, Timo
    Boehm, Ruwen
    Latz, Svea-Kristina
    Hoecker, Jan
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2016, 33 (05) : 334 - 340
  • [8] Passive Warming using a Heat-Band versus a Resistive Heating Blanket for the Prevention of Inadvertent Perioperative Hypothermia during Laparotomy for Gynaecological Surgery
    Fadzlina, Wan Muhd Shukeri Wan
    Nazaruddin, Wan Hassan Wan Mohd
    Hardy, Mohamad Zaini Rhendra
    [J]. MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2016, 23 (02): : 28 - 37
  • [9] Amino acid infusions started after development of intraoperative core hypothermia do not affect rewarming but reduce the incidence of postoperative shivering during major abdominal surgery: a randomized trial
    Inoue, Satoki
    Shinjo, Takeaki
    Kawaguchi, Masahiko
    Nakajima, Yoshiyuki
    Furuya, Hitoshi
    [J]. JOURNAL OF ANESTHESIA, 2011, 25 (06) : 850 - 854
  • [10] Amino acid infusions started after development of intraoperative core hypothermia do not affect rewarming but reduce the incidence of postoperative shivering during major abdominal surgery: a randomized trial
    Satoki Inoue
    Takeaki Shinjo
    Masahiko Kawaguchi
    Yoshiyuki Nakajima
    Hitoshi Furuya
    [J]. Journal of Anesthesia, 2011, 25 : 850 - 854