Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors

被引:21
|
作者
Flanigan, D. [1 ]
McCarrick, H. [1 ]
Jones, G. [1 ]
Johnson, B. R. [1 ]
Abitbol, M. H. [1 ]
Ade, P. [2 ]
Araujo, D. [1 ]
Bradford, K. [3 ]
Cantor, R. [4 ]
Che, G. [5 ]
Day, P. [6 ]
Doyle, S. [2 ]
Kjellstrand, C. B. [1 ]
Leduc, H. [6 ]
Limon, M. [1 ]
Luu, V. [1 ]
Mauskopf, P. [2 ,3 ]
Miller, A. [1 ]
Mroczkowski, T. [7 ]
Tucker, C. [2 ]
Zmuidzinas, J. [6 ,8 ]
机构
[1] Columbia Univ, Dept Phys, 538 W 120th St, New York, NY 10027 USA
[2] Cardiff Univ, Sch Phys & Astron, Cardiff CF24 3AA, S Glam, Wales
[3] Arizona State Univ, Sch Earth & Space Explorat, Tempe, AZ 85287 USA
[4] STAR Cryoelect, Santa Fe, NM 87508 USA
[5] Arizona State Univ, Dept Phys, Tempe, AZ 85287 USA
[6] CALTECH, Jet Prop Lab, 4800 Oak Grove Dr, Pasadena, CA 91109 USA
[7] US Navy, Res Lab, Washington, DC 20375 USA
[8] CALTECH, Div Phys Math & Astron, Pasadena, CA 91125 USA
关键词
FLUCTUATIONS;
D O I
10.1063/1.4942804
中图分类号
O59 [应用物理学];
学科分类号
摘要
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generator. We demonstrate that the detector response over a 40 dB range of source power is well-described by a simple model that considers the number of quasiparticles. The detector noise-equivalent power (NEP) is dominated by photon noise when the absorbed power is greater than approximately 1 pW, which corresponds to NEP approximate to 2 x 10(-17) WH z(-1/2), referenced to absorbed power. At higher source power levels, we observe the relationships between noise and power expected from the photon statistics of the source signal: NEP proportional to P for broadband (chaotic) illumination and NEP proportional to P-1/2 for continuous-wave (coherent) illumination. (C) 2016 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:5
相关论文
共 3 条
  • [1] Horn-coupled, commercially-fabricated aluminum lumped-element kinetic inductance detectors for millimeter wavelengths
    McCarrick, H.
    Flanigan, D.
    Jones, G.
    Johnson, B. R.
    Ade, P.
    Araujo, D.
    Bradford, K.
    Cantor, R.
    Che, G.
    Day, P.
    Doyle, S.
    Leduc, H.
    Limon, M.
    Luu, V.
    Mauskopf, P.
    Miller, A.
    Mroczkowski, T.
    Tucker, C.
    Zmuidzinas, J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (12):
  • [2] A horn-coupled millimetre-wave on-chip spectrometer based on lumped-element kinetic inductance detectors
    Chowdhury, U.
    Levy-Bertrand, F.
    Calvo, M.
    Goupy, J.
    Monfardini, A.
    [J]. ASTRONOMY & ASTROPHYSICS, 2023, 672
  • [3] Design and performance of dual-polarization lumped-element kinetic inductance detectors for millimeter-wave polarimetry
    McCarrick, H.
    Jones, G.
    Johnson, B. R.
    Abitbol, M. H.
    Ade, P. A. R.
    Bryan, S.
    Day, P.
    Essinger-Hileman, T.
    Flanigan, D.
    Leduc, H. G.
    Limon, M.
    Mauskopf, P.
    Miller, A.
    Tucker, C.
    [J]. ASTRONOMY & ASTROPHYSICS, 2018, 610