Translucency rendering in 3D endoluminal CT colonography: A useful tool for increasing polyp specificity and decreasing interpretation time

被引:37
|
作者
Pickhardt, PJ [1 ]
机构
[1] Univ Wisconsin, Sch Med, Ctr Clin Sci, Dept Radiol, Madison, WI 53792 USA
关键词
D O I
10.2214/ajr.183.2.1830429
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
[No abstract available]
引用
收藏
页码:429 / 436
页数:8
相关论文
共 37 条
  • [1] Diagnostic accuracy of translucency rendering to differentiate polyps from pseudopolyps at 3D endoluminal CT colonography: a feasibility study
    Guerrisi, A.
    Marin, D.
    Laghi, A.
    Di Martino, M.
    Iafrate, F.
    Iannaccone, R.
    Catalano, C.
    Passariello, R.
    RADIOLOGIA MEDICA, 2010, 115 (05): : 758 - 770
  • [2] Transparent rendering of intraluminal contrast for 3D polyp visualization at CT colonography
    Shi, Rong
    Napel, Sandy
    Rosenberg, Jarrett K.
    Shin, Lewis K.
    Walsh, Cynthia F.
    Mogensen, Monique A.
    Joshi, Ajay Jayant
    Pankhudi, Pankhudi
    Beaulieu, Christopher F.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (05) : 773 - 779
  • [3] Linear polyp measurement at CT colonography: 3D endoluminal measurement with optimized surface-rendering threshold value and automated measurement
    Park, Seong Ho
    Choi, Eugene K.
    Lee, Seung Soo
    Woo, Ji Young
    Chung, Soo Young
    Kim, Young Jun
    Han, Joon Koo
    Ha, Hyun Kwon
    RADIOLOGY, 2008, 246 (01) : 157 - 167
  • [4] Surface visualization at 3D endoluminal CT colonography: Degree of coverage and implications for polyp detection
    Pickhardt, PJ
    Taylor, AJ
    Gopal, DV
    GASTROENTEROLOGY, 2006, 130 (06) : 1582 - 1587
  • [5] Wide angle 3d endoluminal CT colonography: Impact on missed areas and polyp conspicuity
    East, James E.
    Saunders, Brian P.
    Boone, Darren
    Burling, David
    Halligan, Steve
    Taylor, Stuart A.
    GASTROENTEROLOGY, 2007, 132 (04) : A352 - A352
  • [6] Wide angle 3D endoluminal CT colonography: Impact on missed areas and polyp conspicuity
    East, J. E.
    Saunders, B. P.
    Boone, D.
    Halligan, S.
    Taylor, S. A.
    GUT, 2007, 56 : A77 - A77
  • [7] Fast perspective volume ray casting method using GPU-based acceleration techniques for translucency rendering in 3D endoluminal CT colonography
    Lee, Taek-Hee
    Lee, Jeongjin
    Lee, Ho
    Kye, Heewon
    Shin, Yeong Gil
    Kim, Soo Hong
    COMPUTERS IN BIOLOGY AND MEDICINE, 2009, 39 (08) : 657 - 666
  • [8] Polyp detection at CT colonography: Inadequate primary 3D endoluminal reference standard precludes meaningful comparison
    Pickhardt, Perry J.
    RADIOLOGY, 2007, 244 (01) : 316 - 317
  • [9] Polyp detection at CT colonography: Inadequate primary 3D endoluminal reference standard precludes meaningful comparison - Response
    Taylor, Stuart A.
    Halligan, Steve
    RADIOLOGY, 2007, 244 (01) : 317 - 317
  • [10] Comparison of a unidirectional panoramic 3D endoluminal interpretation technique to traditional 2D and bidirectional 3D interpretation techniques at CT colonography: preliminary observations
    Lenhart, D. K.
    Babb, J.
    Bonavita, J.
    Kim, D.
    Bini, E. J.
    Megibow, A. J.
    Macari, M.
    CLINICAL RADIOLOGY, 2010, 65 (02) : 118 - 125