Clearance and renal extraction of technetium-99m-L,L-ethylenedicysteine, I-131-ortho-iodohippurate and I-125-iothalamate in pigs

被引:5
|
作者
Nielsen, SS
Poulsen, EU
Marqversen, J
Nielsen, LE
Bacher, T
Rehling, M
机构
[1] Aarhus Univ Hosp, Dept Clin Physiol & Nucl Med, Skejby Sect, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Dept Urol, Skejby Sect, DK-8200 Aarhus, Denmark
来源
CLINICAL PHYSIOLOGY | 1999年 / 19卷 / 04期
关键词
clearance; effective renal plasma flow; renal extraction; porcine;
D O I
10.1046/j.1365-2281.1999.00186.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
99mTc-L,L-ethylenedicysteine (Tc-99m-EC) has been proposed as a Tc-99m-labelled alternative to radio-iodinated ortho-iodohippurate (OIH) for renal imaging and evaluation of renal function. The kinetics of this new renal function agent were studied by a single-injection plasma clearance technique in pigs. Tc-99m-EC, I-131-OIH and I-125-iothalamate were injected and the plasma concentration of the three tracers was followed for 240 min. Renal, hepatic and total plasma clearance were calculated. There was no difference between the renal plasma clearance of Tc-99m-EC and I-131-OIH (175 +/- 9 versus 178 +/- 8 ml min(-1), P = 0.43), whereas the difference between the total plasma clearance of Tc-99m-EC and I-131-OIH was highly significant (268 +/- 16 versus 185 +/- 9 ml min(-1), P=0.0001). Tc-99m-EC had a significant hepatic clearance of 83 +/- 10 ml min(-1) whereas the hepatic clearance of I-131-OIH was negligible. Renal plasma extraction of both Tc-99m-EC and I-131-OIH decreased significantly between 2 and 240 min post-injection from 0.85 to 0.45% for Tc-99m-EC and from 0.93 to 0.57% for I-131-OIH. Red blood cell binding of 99mTc-EC and I-131-OIH was 6.1% and 20%, respectively. The protein binding of Tc-99m-EC and I-131-OIH was 32% for both tracers. We conclude that Tc-99m-EC is not a suitable tracer for measuring renal function by the single-injection plasma clearance technique in pigs. This is due to a decreasing renal extraction and a significant hepatic clearance.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 17 条
  • [1] Clearance and renal extraction of technetium-99m-L,L-ethylenedicysteine, I-131-ortho-iodohippurate and I-125-iothalamate in pigs (vol 19, pg 338, 1999)
    Nielsen, SS
    Poulsen, EU
    Marqversen, J
    Nielsen, LE
    Bacher, T
    Rehling, M
    CLINICAL PHYSIOLOGY, 1999, 19 (06): : 527 - 527
  • [2] TECHNETIUM-99M-L,L-ETHYLENEDICYSTEINE SCINTIGRAPHY IN PATIENTS WITH RENAL DISORDERS
    GUPTA, NK
    BOMANJI, JB
    WADDINGTON, W
    LUI, D
    COSTA, DC
    VERBRUGGEN, AM
    ELL, PJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (07): : 617 - 624
  • [3] Clinical evaluation of technetium-99m-L,L-ethylenedicysteine in patients with chronic renal failure
    Prvulovich, EM
    Bomanji, JB
    Waddington, WA
    Rudrasingham, P
    Verbruggen, AM
    Ell, PJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 809 - 814
  • [4] TECHNETIUM-99M-L,L-ETHYLENEDICYSTEINE - A RENAL IMAGING AGENT .1. LABELING AND EVALUATION IN ANIMALS
    VERBRUGGEN, AM
    NOSCO, DL
    VANNEROM, CG
    BORMANS, GM
    ADRIAENS, PJ
    DEROO, MJ
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (04) : 551 - 557
  • [5] The use of renal scintigraphy with technetium-99m-L,L-ethylenedicysteine in critically ill patients with acute renal failure in the intensive care unit
    PL Corrêa
    RC Felix
    P Dutra
    M Desser
    JF Ferreira
    RC Costa-Filho
    JLF Costa
    CM Mesquita
    Critical Care, 7 (Suppl 3):
  • [6] Technetium-99m L,L-ethylenedicysteine clearance and correlation with iodine-125 orthoiodohippurate for the determination of effective renal plasma flow
    Stoffel, M
    Jamar, F
    VanNerom, C
    Verbruggen, A
    Besse, T
    Squifflet, JP
    Beckers, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (04): : 365 - 370
  • [7] Technetium-99m-L,L-ethylenedicysteine renal scan as a single-modality investigation for the evaluation of renal morphology and function: a comparative study with technetium-99m-dimercaptosuccinic acid
    Narayana, C
    Tripathi, M
    Kumar, A
    Gowda, NK
    Phom, H
    Chandra, P
    Bandopadhyaya, G
    Bal, C
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (07) : 743 - 747
  • [8] Technetium-99m-L,L-Ethylenedicysteine Is More Effective Than Technetium-99m Diethylenetriamine Penta-acetic Acid for Excluding Obstruction in Patients With Pyelocalicinal Dilation
    Lima, Mariana C. L.
    de Lima, Marcelo Lopes
    Pepe, Carlos F. V.
    Etchebehere, Elba C. S. C.
    Santos, Allan O.
    Amorim, Barbara J.
    Camargo, Edwaldo E.
    Ferreira, Ubirajara
    Palma, Paulo C. R.
    Ramos, Celso D.
    UROLOGY, 2010, 76 (02) : 283 - 288
  • [9] ERROR DEPENDENT ON RENAL-FUNCTION WHEN MONOEXPONENTIAL EQUATION ASSUMED - SERUM CLEARANCES OF I-125-IOTHALAMATE AND I-131-O-IODOHIPPURATE
    MACKICHAN, JJ
    DOBRINSKA, MR
    WELLING, PG
    WAGNER, JG
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 1977, 22 (05) : 609 - 614
  • [10] KINETIC AND CLINICAL COMPARISON OF TC-99M-DIETHYLENETRIAMINE PENTAACETIC ACID, I-131-ORTHOIODOHIPPURATE AND I-125-IOTHALAMATE
    TREVES, S
    SPENCER, RP
    JOURNAL OF NUCLEAR MEDICINE, 1970, 11 (10) : 645 - &