Crosstalk in Circular Arrays of Magnetic Sensors for Current Measurement

被引:61
|
作者
Weiss, Roland [1 ]
Makuch, Rory [2 ]
Itzke, Alexander [1 ]
Weigel, Robert [3 ]
机构
[1] Siemens AG, Corporate Technol, Sensor Syst Integrat, D-91058 Erlangen, Germany
[2] Univ Rhode Isl, Dept Elect Comp & Biomed Engn, Kingston, RI 02881 USA
[3] Friedrich Alexander Univ Erlangen Nuremberg, Inst Tech Elect, D-91058 Erlangen, Germany
关键词
Closed loop; crosstalk interference; current sensing; error rejection; fluxgate sensors; open loop; sensor arrays;
D O I
10.1109/TIE.2017.2674630
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Circular arrays of magnetic-field sensors are of high interest in the field of power electronics for use in galvanically isolated dc current sensing. The low power consumption, high sensitivity, and mechanical flexibility of modern circular arrays of magnetic sensors for current measurement are an improvement over older closed-loop high power consumption systems. Due to their high sensitivity, such magnetic sensor arrangements are strongly influenced by magnetic fields originating not only from a targeted conductor but also from sources of interference. In this paper, we present a theoretical and experimental evaluation of the crosstalk interference in a circular array of fluxgate sensors for current measurement. We attempt to improve the modeling and the experimental setup of the state of the art method by applying a displacement in the angular position of the sensing array. Utilizing our techniques in the experimental evaluation of the rejection method, we have seen an improvement in error rejection and in turn an increased measurement accuracy of our target current source. In the best case, we have seen accuracy to within 0.02% of the current measured.
引用
收藏
页码:4903 / 4909
页数:7
相关论文
共 50 条
  • [1] Circular arrays of magnetic sensors for current measurement
    Di Rienzo, L
    Bazzocchi, R
    Manara, A
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (05) : 1093 - 1096
  • [2] Crosstalk Analysis and Current Measurement Correction in Circular 3D Magnetic Sensors Arrays
    Guo, Chunxian
    Zhang, Huaiqing
    Guo, Huan
    Chen, Lin
    Chen, Weihao
    Yu, Nian
    IEEE SENSORS JOURNAL, 2021, 21 (03) : 3121 - 3133
  • [3] Current Measurement of Flat Conductors with a Circular Array of Magnetic Sensors
    Weiss, R.
    Itzke, A.
    Weigel, R.
    2017 IEEE SECOND INTERNATIONAL CONFERENCE ON DC MICROGRIDS (ICDCM), 2017, : 166 - 170
  • [4] Crosstalk in Elliptical Sensor Arrays for Current Measurement
    Zapf, Florian
    Weiss, Roland
    Weigel, Robert
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [5] Magnetic crosstalk minimization in optical current sensors
    Daniel Perciante, Cesar
    Ferrari, Jose A.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (10) : 2304 - 2308
  • [6] Circular Array of Magnetic Sensors for Current Measurement: Analysis for Error Caused by Position of Conductor
    Yu, Hao
    Qian, Zheng
    Liu, Huayi
    Qu, Jiaqi
    SENSORS, 2018, 18 (02)
  • [7] Analysis of Crosstalk in Networked Arrays of Resistive Sensors
    Saxena, Raghvendra Sahai
    Saini, Navneet Kaur
    Bhan, R. K.
    IEEE SENSORS JOURNAL, 2011, 11 (04) : 920 - 924
  • [8] Contactless measurement of electric current using magnetic sensors
    Ripka, Pavel
    TM-TECHNISCHES MESSEN, 2019, 86 (10) : 586 - 598
  • [9] On Isotropic Circular Arrays of Anisotropic Sensors
    Gazzah, Houcem
    Delmas, Jean Pierre
    2015 IEEE INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY (ISSPIT), 2015, : 95 - 99
  • [10] Influence of the Conductor Position on a Circular Array of Hall Sensors for Current Measurement
    Itzke, Alexander
    Weiss, Roland
    Weigel, Robert
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (01) : 580 - 585