A split-mouth randomized clinical trial of conventional and heavy flowable composites in class II restorations

被引:36
|
作者
Gomes Torres, Carlos Rocha [1 ]
Chagas Rego, Heleine Maria [1 ]
Costa Perote, Leticia C. C. [1 ]
Santos, Luciana F. Thives F. [1 ]
Beber Kamozaki, Maria Beatriz [1 ]
Gutierrez, Natalia Cortez [1 ]
Di Nicolo, Rebeca [1 ]
Borges, Alessandra Buehler [1 ]
机构
[1] UNESP, Sao Paulo State Univ, Sao Jose Dos Campos Sch Dent, Dept Restorat Dent, Sao Jose Dos Campos, SP, Brazil
关键词
Composite resin; Clinical trial; Dental restorations; USPHS criteria; Flowable; RESIN-COMPOSITES; NANOHYBRID; SYSTEMS; MICROLEAKAGE; PERFORMANCE; SHRINKAGE; NANOFILL; TEETH;
D O I
10.1016/j.jdent.2014.04.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this study was to evaluate the 2-year clinical performance of class II restorations made with a composite resin with two different viscosities. Methods: 47 patients received two class II restorations (n = 94), one made with GrandioSO (conventional viscosity CV), and the other with GrandioSO Heavy Flow (flowable viscosity FV), subjecting both materials to the same clinical conditions. The self-etching adhesive Futurabond M was used for all restorations. The composites were inserted using the incremental technique. The restorations were evaluated using the modified USPHS criteria according to the periods: baseline, 6 months, 1 year and 2 years after restorative procedures. Results: After 24 months, 40 patients attended the recall and 78 restorations were evaluated. In all periods, no secondary caries was observed. After 6 months, there were slightly overall changes of scores for most parameters. After 24 months, the higher number of changes from score Alfa to Bravo was observed for marginal discolouration (32.5% CV and 39.5% FV) and colour match (15% CV and 31.6% FV), followed by proximal contact (25% CV and 23.7% FV) and marginal adaptation (20% CV and 21.1% FV). For wear, surface texture and postoperative sensitivity the changes were very small. Just two restorations were lost during the 24-month follow up. Less than 5% of all restorations showed postoperative sensitivity. Chi-square test showed no significant differences between the two materials for all parameters analysed. Conclusion: After 2 years of clinical service, no significant differences were observed between GrandioSO conventional and GrandioSO Heavy Flow for the parameters analysed. Both materials provided acceptable clinical behaviour in class II restorations. Clinical Significance: This study presents the possibility of using a flowable composite with high filler content, for performing class II restorations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:793 / 799
页数:7
相关论文
共 50 条
  • [1] Postoperative sensitivity in posterior restorations restored with self-adhesive and conventional bulk-fill resin composites: A randomized clinical split-mouth trial
    Maghaireh, Ghada A.
    Albashaireh, Zakereyya S.
    Allouz, Hadeel A.
    [J]. JOURNAL OF DENTISTRY, 2023, 137
  • [2] Issues with the conduct and reporting of split-mouth randomized clinical trial
    Dhingra, Kunaal
    Chaudhari, Prabhat Kumar
    Gupta, Shalini
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 158 (05) : 634 - 635
  • [3] Two-year Randomized, Controlled Clinical Trial of a Flowable and Conventional Composite in Class I Restorations
    Lawson, N. C.
    Radhakrishnan, R.
    Givan, D. A.
    Ramp, L. C.
    Burgess, J. O.
    [J]. OPERATIVE DENTISTRY, 2015, 40 (06) : 594 - 602
  • [4] Bulk-fill versus layering pure ormocer posterior restorations: A randomized split-mouth clinical trial
    Gomes Torres, Carlos Rocha
    Barbosa Jurema, Ana Luiza
    De Souza, Mauricio Yugo
    Di Nicolo, Rebeca
    Borges, Alessandra Buhler
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2021, 34 (03): : 143 - 149
  • [5] Issues with the conduct and reporting of split-mouth randomized clinical trial Response
    Pacheco, Ariel Adriano Reyes
    Collins, James Rudolph
    Contreras, Nelsida
    Lantigua, Astrid
    Pithon, Matheus Melo
    Tanaka, Orlando Motohiro
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 158 (05) : 635 - 636
  • [6] Effect of 940 nm laser diode irradiation prior to bonding procedure on postoperative sensitivity following class II composite restorations: a split-mouth randomized clinical trial
    Rezaei-Soufi, Loghman
    Taheri, Mojgan
    Fekrazadas, Reza
    Farhadian, Maryam
    [J]. LASERS IN MEDICAL SCIENCE, 2021, 36 (05) : 1109 - 1116
  • [7] Effect of 940 nm laser diode irradiation prior to bonding procedure on postoperative sensitivity following class II composite restorations: a split-mouth randomized clinical trial
    Loghman Rezaei-Soufi
    Mojgan Taheri
    Reza Fekrazadas
    Maryam Farhadian
    [J]. Lasers in Medical Science, 2021, 36 : 1109 - 1116
  • [8] Desensitizing treatments for dentin hypersensitivity: a randomized, split-mouth clinical trial
    Camilotti, Veridiana
    Zilly, Juliana
    Ribeiro Busato, Priscilla do Monte
    Nassar, Carlos Augusto
    Nassar, Patricia Oehlmeyer
    [J]. BRAZILIAN ORAL RESEARCH, 2012, 26 (03): : 263 - 268
  • [9] Three-year Randomized Prospective Clinical Trial of Class II Restorations Using Flowable Bulk-fill Resin Composites
    Moda, M. D.
    Briso, A. F.
    Hoshino, I. A. E.
    Frascino, S. M. B.
    Santos, P. H.
    Goncalves, D. M.
    Fagundes, T. C.
    [J]. OPERATIVE DENTISTRY, 2021, 46 (05) : 516 - 528
  • [10] Clinical Effectiveness of Salvia officinalis in Periodontitis: A Split-Mouth Randomized Controlled Trial
    Aljuboori, Ismael W.
    Mahmood, Maha S.
    Al-Rihaymee, Sarah A.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)