Multi-Mode TFM Imaging with Artifacts Filtering Using CIVA UT Forwards Models

被引:33
|
作者
Iakovleva, Ekaterina [1 ]
Chatillon, Sylvain [1 ]
Bredif, Philippe [1 ]
Mahaut, Steve [1 ]
机构
[1] CEA, LIST, DISC, F-91191 Gif Sur Yvette, France
关键词
Phased Arrays; UT Inspection; Imaging; Simulation; TFM; Artifacts; Filtering;
D O I
10.1063/1.4864804
中图分类号
O59 [应用物理学];
学科分类号
摘要
TFM (Total Focusing Method) is an advanced post-processing imaging algorithm of ultrasonic array data that shows great potential in defect detection and characterization. This technique can be performed using several propagation modes (direct or over skip imaging) and several types of waves (longitudinal or transverse) allowing the imaging of extended defects of complex geometry. However, non physical indications can be observed, leading to misinterpretation. These imaging artifacts are due to the coexistence of several contributions involving several mode of propagation and interactions with possible defects and / or the geometry of the part. In several configurations, a simple time of flight criterion is not sufficient for their identification. This paper presents tools based on the forward CIVA UT models which allow to analyze and to filter these artifacts, without any tuning parameters. The performances achieved are compared to those of conventional TFM on simulated and experimental data.
引用
收藏
页码:72 / 79
页数:8
相关论文
共 50 条
  • [1] Results of the 2014 UT Modeling Benchmark Obtained with Models Implemented in CIVA Solution of the FMC-TFM Ultrasonic Benchmark Problem Using CIVA
    Chatillon, Sylvain
    Robert, Sebastien
    Bredif, Philippe
    Calmon, Pierre
    Daniel, Guillaume
    Cartier, Francois
    41ST ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 34, 2015, 1650 : 1847 - 1855
  • [2] Development of methods for the analysis of multi-mode TFM images
    Sy, K.
    Bredif, P.
    Iakovleva, E.
    Roy, O.
    Lesselier, D.
    16TH ANGLO-FRENCH PHYSICAL ACOUSTICS CONFERENCE (AFPAC), 2018, 1017
  • [3] Multi-mode high resolution TFM imaging of microdefects based on laser ultrasonic full matrix capture
    Liu, Zenghua
    Chen, Long
    Zhu, Yanping
    Liu, Xiaoyu
    He, Cunfu
    OPTICS AND LASER TECHNOLOGY, 2025, 181
  • [4] Multi-mode cochlear models
    Hubbard, AE
    Yang, Z
    Shatz, L
    Mountain, DC
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON RECENT DEVELOPMENTS IN AUDITORY MECHANICS, 2000, : 167 - 173
  • [5] Entry flow calculations using multi-mode models
    Azaiez, J
    Guenette, R
    AitKadi, A
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 1996, 66 (2-3) : 271 - 281
  • [6] Pedestrian Localization by Appearance Matching and Multi-mode Filtering
    Wu, Shunguang
    Bansal, Mayank
    Eledath, Jayan
    2009 IEEE INTELLIGENT VEHICLES SYMPOSIUM, VOLS 1 AND 2, 2009, : 172 - 178
  • [7] Optical Interconnects Using Single-Mode and Multi-Mode VCSEL and Multi-Mode Fiber
    Ledentsov, N. N.
    Shchukin, V. A.
    Kalosha, V. P.
    Ledentsov, N., Jr.
    Chorchos, L.
    Turkiewicz, J. P.
    Hecht, U.
    Kurth, P.
    Gerfers, F.
    Lavrencik, J.
    Varughese, S.
    Ralph, S. E.
    2020 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXPOSITION (OFC), 2020,
  • [8] Simultaneous Multi-Mode Automotive Imaging Radar Using Cascaded Transceivers
    Jansen, F. G.
    Laghezza, F.
    Alhasson, S.
    Lok, P.
    van Meurs, L. M. A.
    Geraets, R.
    Paker, O.
    Overdevest, J.
    2021 18TH EUROPEAN RADAR CONFERENCE (EURAD), 2021, : 441 - 444
  • [9] Designing a spaceborne SAR for multi-mode imaging
    Brand, A
    Ali, Z
    1996 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING - CONFERENCE PROCEEDINGS, VOLS I AND II: THEME - GLIMPSE INTO THE 21ST CENTURY, 1996, : 17 - 20
  • [10] The Use of Multi-mode TFM to Measure the Depth of Small Surface-break Cracks in Welds
    Yu, Peng
    Gang, Tie
    PROCEEDINGS OF 2017 IEEE FAR EAST FORUM ON NONDESTRUCTIVE EVALUATION/TESTING: NEW TECHNOLOGY & APPLICATION (IEEE FENDT 2017), 2017, : 106 - 110