Initial Clinical Evaluation of Gated Stationary Digital Chest Tomosynthesis

被引:2
|
作者
Lee, Yueh Z. [1 ]
Gunnell, Taylor [2 ]
Inscoe, Christy R. [3 ]
Puett, Connor [2 ]
Lu, Jianping [3 ]
Zhou, Otto [3 ]
机构
[1] Univ North Carolina Chapel Hill, Dept Radiol, Chapel Hill, NC 27599 USA
[2] Univ North Carolina Chapel Hill, Sch Med, Chapel Hill, NC 27599 USA
[3] Univ North Carolina Chapel Hill, Dept Phys & Astron, Chapel Hill, NC 27599 USA
关键词
digital chest tomosynthesis; carbon nanotube x-ray; stationary digital chest tomosynthesis; cystic fibrosis; respiration gated; CYSTIC-FIBROSIS; RADIOGRAPHY;
D O I
10.1117/12.2293713
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High resolution imaging of the chest is dependent on a breath hold maintained throughout the imaging time. However, pediatric and comatose patients are unable to follow respiration commands Gated tomosynthesis could offer a lower dose, high in-plane resolution imaging modality, but current systems are unable to prospectively gate in a reasonable scan time. In contrast, a carbon nanotube (CNT) based linear x-ray source array offers both the angular span and precise control necessary to generate x-ray projections for gated tomosynthesis. The goal of this study was to explore the first clinical use of the CNT linear x-ray source array for gated clinical chest imaging. Eighteen pediatric cystic fibrosis patients were recruited for this study, with 13 usable image sets. The s-GDCT system consists of a CNT linear x-ray source array coupled with a digital detector. A respiration signal derived from a respiratory belt served as a gating signal with sources fired sequentially when the imaging window and maximum inspiration window coincided. Images were reconstructed and reviewed for motion blur and ability to identify major anatomical structures. Image quality was highly dependent on quality of the respiration gating signal, and a correlation was found between qualitative image quality and height of the respiration peak. We demonstrate the first prospectively gated evaluation of the stationary digital chest tomosynthesis patients in pediatric patients. Though further refinements in projection selection and respiratory gating approaches are necessary, this study demonstrates the potential utility of this low dose imaging approach
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Initial clinical evaluation of stationary digital chest tomosynthesis
    Hartman, Allison E.
    Shan, Jing
    Wu, Gongting
    Lee, Yueh Z.
    Zhou, Otto
    Lu, Jianping
    Heath, Michael
    Wang, Xiaohui
    Foos, David
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [2] Initial clinical evaluation of stationary digital chest tomosynthesis in adult patients with cystic fibrosis
    Elias Taylor Gunnell
    Dora K. Franceschi
    Christina R. Inscoe
    Allison Hartman
    Jennifer L. Goralski
    Agathe Ceppe
    Brian Handly
    Cassandra Sams
    Lynn Ansley Fordham
    Jianping Lu
    Otto Zhou
    Yueh Z. Lee
    [J]. European Radiology, 2019, 29 : 1665 - 1673
  • [3] Initial clinical evaluation of stationary digital chest tomosynthesis in adult patients with cystic fibrosis
    Gunnell, Elias Taylor
    Franceschi, Dora K.
    Inscoe, Christina R.
    Hartman, Allison
    Goralski, Jennifer L.
    Ceppe, Agathe
    Handly, Brian
    Sams, Cassandra
    Fordham, Lynn Ansley
    Lu, Jianping
    Zhou, Otto
    Lee, Yueh Z.
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (04) : 1665 - 1673
  • [4] Initial clinical evaluation of stationary digital breast tomosynthesis
    Calliste, Jabari
    Tucker, Andrew W.
    Gidcumb, Emily
    Kuzmiak, Cherie M.
    Lu, Jianping
    Zhou, Otto
    Lee, Yueh Z.
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [5] In-Vivo Evaluation of Prospective Respiratory Gated Stationary Digital Chest Tomosynthesis Imaging
    Hartman, A.
    Gunnell, E.
    Inscoe, C.
    Lu, J.
    Zhou, O.
    Lee, Y.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3263 - 3263
  • [6] Initial Clinical Experience with Stationary Digital Breast Tomosynthesis
    Lee, Yueh Z.
    Puett, Connor
    Inscoe, Christina R.
    Jia, Beilin
    Kim, Connie
    Walsh, Ruth
    Yoon, Sora
    Kim, Suk Jung
    Kuzmiak, Cherie M.
    Zeng, Donglin
    Lu, Jianping
    Zhou, Otto
    [J]. ACADEMIC RADIOLOGY, 2019, 26 (10) : 1363 - 1372
  • [7] Stationary Digital Chest Tomosynthesis Of Cystic Fibrosis
    Lee, Y. Z.
    Goralski, J. L.
    Hartman, A.
    Wu, G.
    Donaldson, S.
    Boucher, R. C.
    Zhou, O.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [8] Initial clinical evaluation of chest digital tomosynthesis in adult patients with COVID-19 pneumonia
    Li Zhanxia
    Wu Xiuhua
    Zhang Guobin
    Wu Dianliang
    Zhang Yunjiao
    Wang Chengji
    Zou Lumin
    Gu Xiaohua
    Ren Tao
    [J]. 中华医学杂志英文版, 2024, 137 (18)
  • [9] Evaluation of imaging geometry for stationary chest tomosynthesis
    Shan, Jing
    Tucker, Andrew W.
    Lee, Yueh Z.
    Heath, Michael D.
    Wang, Xiaohui
    Foos, David
    Lu, Jianping
    Zhou, Otto
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [10] Stationary Digital Chest Tomosynthesis for Coronary Artery Calcium Scoring
    Wu, Gongting
    Wang, Jiong
    Potzuko, Marci
    Harman, Allison
    Pearce, Caleb
    Shan, Jing
    Lee, Yueh Z.
    Zhou, Otto
    Lu, Jianping
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783