Impact of prostate volume evaluation by different observers on CT-based post-implant dosimetry

被引:66
|
作者
Al-Qaisieh, B
Ash, D
Bottomley, DM
Carey, BM
机构
[1] Cookridge Hosp, Dept Med Phys, Leeds LS16 6QB, W Yorkshire, England
[2] Cookridge Hosp, Yorkshire Regional Ctr Canc Treatment, Leeds LS16 6QB, W Yorkshire, England
关键词
prostate brachytherapy; postimplant dosimetry;
D O I
10.1016/S0167-8140(01)00475-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: An analysis Of Computed tomography (CT)-based dosimetry was performed to evaluate the variability of different observers' judgements in marking the prostate gland on CT films, and its effect on the parameters that characterise the prostate implantation quality. Accuracy of data entry by the First author in the process of dosimetry procedure has also been evaluated. Materials and methods: Four observers were asked to evaluate the prostate volume on CT films for six different patients. Each observer repeated the evaluation six times. The sample of patients has a prostate volume in the range of 21.4-42.0 cc derived from transrectal ultrasound volume study. After an average period of 6 weeks of the I-125 implantation, all patients had CT scans. CT-based post-implant dosimetry was performed and the dose volume histograms DVHs were calculated to report the re-constructed prostate Volume, Vp100, Vp150, Vp90 and D90. Comparison between the four observers' output was performed. Results: Comparison between the four observers shows that each observer has a different way of estimating the prostate on CT films. Observers' precision also varies according to the prostate volume and the image quality. This can cause a variation in the resulting D90 value by up to 50%. Analysis of data entry shows a high degree of accuracy. The error of digitizing the prostate is +/-0.19 cc. This is correlated to an error of 0.78 Gy of the D90. Conclusion: The evaluation of prostate gland volume on CT films varies between different observers. This has an effect on the dosimetric indices that characterise the implant quality in particular the D90. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:267 / 273
页数:7
相关论文
共 50 条
  • [1] Impact of post-implant evaluation by different slice intervals using CT-based dosimetry in prostate brachytherapy
    Tanaka, O.
    Matsuo, M.
    Hayashi, S.
    Maeda, S.
    Hoshi, H.
    EJC SUPPLEMENTS, 2005, 3 (02): : 254 - 255
  • [2] The impact of pre-implant therapy on prostate volume and the implications for post-implant dosimetry
    Quon, H
    Shasha, D
    Danish, A
    Wagner, J
    Salant, R
    Wang, L
    RADIOLOGY, 2001, 221 : 281 - 282
  • [3] Impact of Seed Localization On Post-Implant Dosimetry in Prostate Brachytherapy
    Chew, M.
    Xue, J.
    Houser, C.
    Misic, V.
    Cao, J.
    Cornwell, T.
    Yu, Y.
    Gressen, E.
    Handler, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [4] COMPARISON OF CT AND MR-CT FUSION FOR PROSTATE POST-IMPLANT DOSIMETRY
    Maletz, Kristina L.
    Ennis, Ronald D.
    Ostenson, Jason
    Pevsner, Alexander
    Kagen, Alexander
    Wernick, Iddo
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1912 - 1917
  • [5] Feasibility of TRUS-based prostate post-implant dosimetry
    Xue, J
    Gressen, E
    MEDICAL PHYSICS, 2004, 31 (06) : 1718 - 1718
  • [6] Effect of a urinary catheter on seed position and rectal and bladder doses in CT-based post-implant dosimetry for prostate cancer brachytherapy
    Kunogi, Hirooki
    Yamaguchi, Nanae
    Wokumoto, Yoshiaki
    Sosoi, Keisuke
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (03) : 211 - 217
  • [7] CT-based post-implant dosimetry for I-125 prostate brachytherapy: a multi-centre audit in the UK and Ireland
    Hayman, O.
    Palmer, A.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2013, 12 (04) : 297 - 304
  • [8] THE EFFECT OF PRO-QURA CASE VOLUME ON POST-IMPLANT PROSTATE DOSIMETRY
    Merrick, Gregory S.
    Lief, Jonathan H.
    Grimm, Peter
    Sylvester, John
    Butler, Wayne M.
    Allen, Zachariah A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : E727 - E734
  • [9] Investigation to Replace CT by MRI in Post-Implant Dosimetry of Prostate Permanent Brachytherapy
    Chen, Q.
    Blair, H.
    Ciezki, J.
    Mahadevan, A.
    Began, N.
    Suh, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [10] A COMPARISON OF POST-IMPLANT US/CT IMAGE FUSION AND MRI/CT FUSION FOR I-125 PROSTATE BRACHYTHERAPY POST-IMPLANT DOSIMETRY
    Patanjali, N.
    Keyes, M.
    Morris, J.
    Liu, M.
    Harrison, R.
    Spadinger, I.
    Moravan, V.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S40 - S40