Interference of paracetamol (acetaminophen) with a commercially available high-performance liquid chromatography analysis of serotonin leading to falsely low serotonin levels

被引:2
|
作者
Pfaefflin, Albrecht [1 ]
Muessig, Karsten [2 ]
Schleicher, Erwin [1 ]
机构
[1] Univ Tubingen Hosp, Dept Internal Med 4, Clin Chem Unit, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Internal Med 4, Endocrine Unit, D-72076 Tubingen, Germany
关键词
CARCINOID-TUMORS; ACID;
D O I
10.1258/acb.2008.008116
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Serotonin is frequently analysed by high-performance liquid chromatography (HPLC) with electrochemical detection. However, the accuracy of these methods may be affected by the presence of certain drugs. We describe for the first time the interference of paracetamol in therapeutic dosages in a routine HPLC method for serotonin determination in vivo and in vitro. The retention time coincides with N-methylserotonin used as an internal standard in this method. Erroneous increases of the internal standard will lead, if not recognized and corrected, to falsely low serotonin determinations.
引用
收藏
页码:146 / 148
页数:3
相关论文
共 50 条
  • [1] PARACETAMOL (ACETAMINOPHEN) ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INTERFERENCE STUDIES AND COMPARISON WITH AN ENZYMATIC PROCEDURE
    STARKEY, BJ
    LOSCOMBE, SM
    SMITH, JM
    THERAPEUTIC DRUG MONITORING, 1986, 8 (01) : 78 - 84
  • [2] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF TRYPTOPHAN AND SEROTONIN METABOLITES
    GARNIER, JP
    BOUSQUET, B
    DREUX, C
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1979, 2 (04): : 539 - 549
  • [3] Analysis of serotonin concentrations in human milk by high-performance liquid chromatography with fluorescence detection
    Chiba, Takeshi
    Maeda, Tomoji
    Tairabune, Tomohiko
    Tomita, Takashi
    Sanbe, Atsushi
    Takeda, Rika
    Kikuchi, Akihiko
    Kudo, Kenzo
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2017, 485 (01) : 102 - 106
  • [4] Simultaneous determination of human plasma levels of four selective serotonin reuptake inhibitors by high-performance liquid chromatography
    Lucca, A
    Gentilini, G
    Lopez-Silva, S
    Soldarini, A
    THERAPEUTIC DRUG MONITORING, 2000, 22 (03) : 271 - 276
  • [5] A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method
    Sono-Koree, N. K.
    Crist, R. A.
    Frank, E. L.
    Rodgers, G. M.
    Smock, K. J.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 (01) : 72 - 80
  • [6] WHOLE-BLOOD HISTAMIN AND SEROTONIN MEASUREMENTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    AKHMEDJANOVA, SB
    BALABOLKIN, II
    VASILYEVA, YM
    ELLER, KI
    LABORATORNOE DELO, 1991, (11): : 10 - 13
  • [7] APPLICATIONS AND LIMITATIONS OF COMMERCIALLY AVAILABLE CHIRAL STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DAPPEN, R
    ARM, H
    MEYER, VR
    JOURNAL OF CHROMATOGRAPHY, 1986, 373 (01): : 1 - 20
  • [8] A high-performance liquid chromatography and nuclear magnetic resonance spectroscopy-based analysis of commercially available praziquantel tablets
    Li, Jia
    Wang, Yulan
    Fenwick, Alan
    Clayton, T. Andrew
    Lau, Yu Y. K.
    Legido-Quigley, Cristina
    Lindon, John C.
    Utzinger, Juerg
    Holmes, Elaine
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (02) : 263 - 267
  • [9] SIMULTANEOUS DETERMINATION OF HISTAMINE AND SEROTONIN IN MAST-CELLS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    EGGER, D
    REISBACH, G
    HULTNER, L
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 662 (01): : 103 - 107
  • [10] DETERMINATION OF SEROTONIN, ITS PRECURSORS, METABOLITES AND [H-3]-SEROTONIN IN LUNG BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    MAIS, DE
    LAHR, PD
    BOSIN, TR
    JOURNAL OF CHROMATOGRAPHY, 1981, 225 (01): : 27 - 35