Influence of stress and phase on corrosion of a superelastic nickel-titanium orthodontic wire

被引:20
|
作者
Segal, Nadav [1 ]
Hell, Jess
Berzins, David W. [1 ]
机构
[1] Marquette Univ, Sch Dent, Dept Dev Sci, Milwaukee, WI 53201 USA
关键词
STAINLESS-STEEL; MECHANICAL-PROPERTIES; ALLOY; RESISTANCE; ARCHWIRES; NITI;
D O I
10.1016/j.ajodo.2007.04.042
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this investigation was to study the effect of stress and phase transformation on the corrosion properties of a superelastic nickel-titanium orthodontic wire. Methods: The phase transformation profiles of superelastic nickel-titanium (Sentalloy, GAC International, Bohemia, NY) and beta-titanium (TMA, Ormco, Orange, Calif) archwires were analyzed by using differential scanning calorimetry. The force/deflection behavior of the wires at 37 degrees C was measured in a 3-point bending test per modified American Dental Association specification no. 32. Electrochemical testing consisted of monitoring the open circuit potential (OCP) for 2 hours followed by polarization resistance and cyclic polarization tests on archwire segments engaged in a 5-bracket simulation apparatus with bend deflections of 0.75, 1.5, or 3 mm in artificial saliva at 37 degrees C. Nondeflected segments were also tested. Sentalloy was additionally examined for bending and corrosion at 5 degrees C, where it exists as martensite and is devoid of stress-induced phase transformation. OCP at 2 hours and corrosion current density (i(corr)) were analyzed by using ANOVA and Tukey tests (alpha = .05) (n = 10 per deflection). Results: Significant differences (P < 0.05) in OCP with deflection were found for the TMA and the Sentalloy wires at 5 degrees C, but not for Sentalloy at 37 degrees C. Significant differences (P <0.05) in i(corr) with deflection were also observed. All 3 wire groups had their lowest mean icorr values when not deflected. The i(corr) for superelastic Sentalloy (37 degrees C) peaked at 0.75 mm deflection before the wire's stress-induced phase transformation point and then decreased with further deflection and transformation. The i(corr) values for TMA and Sentalloy at 5 degrees C, both of which do not undergo phase transformation with deformation, continuously increased from 0 to 1.5 mm deflection before decreasing at the 3.0-mm deflection. Conclusions: Stress increased the corrosion rate in nickel-titanium and beta-titanium orthodontic wires. Alterations in stress/strain associated with phase transformation in superelastic nickel-titanium might alter the corrosion rate in ways different from wires not undergoing phase transformation. (Am J Orthod Dentofacial Orthop 2009;135:764-70)
引用
收藏
页码:764 / 770
页数:7
相关论文
共 50 条
  • [1] FORMULATION OF SUPERELASTIC TENSILE BEHAVIOR OF ORTHODONTIC NICKEL-TITANIUM WIRE
    ARAKI, Y
    SACHDEVA, R
    ENDO, K
    KAWASHIMA, I
    OHNO, H
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 413 - 413
  • [2] Stiffness and frictional resistance of a superelastic nickel-titanium orthodontic wire with low-stress hysteresis
    Liaw, Yu-Cheng
    Su, Yu-Yu M.
    Lai, Yu-Lin
    Lee, Shyh-Yuan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (05) : 578.e12 - 578.e18
  • [3] Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
    Kim, H
    Johnson, JW
    ANGLE ORTHODONTIST, 1999, 69 (01) : 39 - 44
  • [4] Finite element modeling of superelastic nickel-titanium orthodontic wires
    Ben Naceur, Ines
    Charfi, Amin
    Bouraoui, Tarak
    Elleuch, Khaled
    JOURNAL OF BIOMECHANICS, 2014, 47 (15) : 3630 - 3638
  • [5] BENDING PROPERTIES OF SUPERELASTIC AND NONSUPERELASTIC NICKEL-TITANIUM ORTHODONTIC WIRES
    KHIER, SE
    BRANTLEY, WA
    FOURNELLE, RA
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1991, 99 (04) : 310 - 318
  • [6] Load-deflection characteristics of superelastic nickel-titanium orthodontic wires
    Wilkinson, PD
    Dysart, PS
    Hood, JAA
    Herbison, GP
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 121 (05) : 483 - 495
  • [7] FUNCTIONAL PROPERTIES OF SUPERELASTIC ORTHODONTIC NICKEL-TITANIUM ARCHWIRES WITH PROTECTIVE TITANIUM NITRIDE COATINGS
    Rubanik, Vasili V.
    Rubanik, Vasili V., Jr.
    Bahrets, Dzmitry A.
    Dorodeiko, Viachaslau G.
    DOKLADY NATSIONALNOI AKADEMII NAUK BELARUSI, 2019, 63 (05): : 608 - 619
  • [8] Electrochemical research on the corrosion of orthodontic nickel-titanium wires
    Vandenkerckhove, R
    Temmerman, E
    Verbeeck, R
    ELECTROCHEMICAL METHODS IN CORROSION RESEARCH VI, PTS 1 AND 2, 1998, 289-2 : 1289 - 1298
  • [9] Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires
    Katic, Visnja
    Curkovic, Helena Otmacic
    Semenski, Damir
    Barsic, Gorana
    Marusic, Katarina
    Spalj, Stjepan
    ANGLE ORTHODONTIST, 2014, 84 (06) : 1041 - 1048
  • [10] Effect of titanium nitride/titanium coatings on the stress corrosion of nickel-titanium orthodontic archwires in artificial saliva
    Liu, Jia-Kuang
    Liu, I-Hua
    Liu, Cheng
    Chang, Chen-Jung
    Kung, Kuan-Chen
    Liu, Yen-Ting
    Lee, Tzer-Min
    Jou, Jin-Long
    APPLIED SURFACE SCIENCE, 2014, 317 : 974 - 981