In vivo prostate IMRT dosimetry with MOSFET detectors using brass build-up caps

被引:0
|
作者
Varadhan, N.
Garrity, B.
Miller, J.
Weber, M.
机构
[1] Minneapolis Radiat Oncol, Fridley, MN USA
[2] Methodist Hosp, St Louis Pk, MN USA
关键词
D O I
10.1118/1.2240132
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:1985 / 1985
页数:1
相关论文
共 50 条
  • [1] In vivo prostate IMRT dosimetry with MOSFET detectors using brass buildup caps
    Varadhan, Raj
    Miller, John
    Garrity, Brenden
    Weber, Michael
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (04): : 22 - 32
  • [2] Investigation of surface and build-up region dosimetry for obliquely incident IMRT beams
    Dogan, N
    Glasgow, G
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1405 - 1406
  • [3] Evaluation of a recent in vivo dosimetry methodology for HDR prostate BT using MOSFET detectors
    Fabregat Borras, R.
    Ruiz-Arrebola, S.
    Rodriguez Serafin, E.
    Fernandez Montes, M.
    Garcia Blanco, A.
    Cardenal Carro, J.
    Anchuelo Latorre, J. T.
    Ferri Molina, M.
    Kannemann, A.
    Guirado, D.
    Prada, P. J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S522 - S523
  • [4] In vivo measurements with mosfet detectors for IMRT
    Carabante, D.
    Sanchez-Reyes, A.
    Vila, A.
    Pedro, A.
    Julia, J. C.
    Artola, N.
    Lainez, C.
    Fernandez, J.
    Sanchiz, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S374 - S374
  • [5] Accurate dosimetry in photon build-up region
    Abdel-Rahman, W.
    Devic, S.
    Seuntjens, J.
    Podgorsak, E.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2276 - 2276
  • [6] Validation of Film Dosimetry in the Dose Build-Up Region
    Corradini, N.
    Presilla, S.
    Sassowsky, M.
    Schombourg, K.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3613 - 3613
  • [7] Collimator Scatter Factor (Sc) Measurements for IRIS in CyberKnife Using Build-Up Caps
    Lee, S.
    Tien, C.
    Curran, B.
    Jang, S.
    Sternick, E.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [8] In vivo measurements with MOSFET detectors in IMRT of head and neck deseases
    Charpiot, E
    Marcié, S
    Bensadour, RJ
    Costa, A
    Gérard, JP
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S104 - S104
  • [9] ABSORBED FRACTIONS AND BUILD-UP FACTORS FOR DOSIMETRY OF INTERNAL EMITTERS
    REDDY, AR
    AYYANGAR, KM
    BROWNELL, GL
    [J]. HEALTH PHYSICS, 1968, 15 (02): : 198 - +
  • [10] Feasibility study of using MOSFET detectors for in vivo dosimetry during permanent low-dose-rate prostate implants
    Cygler, Joanna E.
    Saoudi, Abdelhamid
    Perry, Gad
    Morash, Christopher
    E, Choan
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 80 (03) : 296 - 301