Dose Prescription Methods in Stereotactic Body Radiotherapy for Small Peripheral Lung Tumors: Approaches Based on the Gross Tumor Volume Are Superior to Prescribing a Dose That Covers 95% of the Planning Target Volume

被引:5
|
作者
Komiyama, Takafumi [1 ]
Saito, Masahide [1 ]
Kuriyama, Kengo [1 ]
Marino, Kan [1 ]
Aoki, Shinichi [1 ]
Saito, Ryo [1 ]
Muramatsu, Juria [1 ]
Maehata, Yoshiyasu [1 ]
Ze, Chen [1 ]
Akita, Tomoko [1 ]
Yamada, Takashi [1 ]
Sano, Naoki [1 ]
Yoshizawa, Kazuya [1 ]
Kazunari, Ashizawa [1 ]
Hidekazu, Suzuki [1 ]
Ueda, Koji [1 ]
Vu, Nam [1 ]
Onishi, Hiroshi [1 ]
机构
[1] Univ Yamanashi, Fac Med, Dept Radiol, 1110 Shimokato, Yamanashi 4093898, Japan
关键词
neoplasms; treatment; radiation therapy; pulmonary neoplasms; non-small cell lung cancer; RADIATION-THERAPY; PHASE-I; CANCER; FRACTIONS; GY;
D O I
10.1177/1533033820974030
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: We aimed to validate the usefulness of prescriptions based on gross tumor volume for stereotactic body radiotherapy for small peripheral lung tumors. Materials and Methods: Radiotherapy treatment planning data of 50 patients with small peripheral lung tumors (adenocarcinoma: 24, squamous cell carcinoma: 10, other: 1, unknown: 15) receiving breath-hold computed tomography-guided stereotactic body radiotherapy at our institution during 2013-2016 were analyzed. For each case, 3 dose prescription methods were applied: one based on 95% (PTVD95%) of the planning target volume, one based on 50% of the gross tumor volume (GTVD(50%)), and one based on 98% (GTVD(98%)) of the gross tumor volume. The maximum (GTVDmax), minimum (GTVDmin), and mean gross tumor volume dose (GTVDmean) and the dose covering 98% of the gross tumor volume were calculated to evaluate variations in the gross tumor volume dose. Results: Upon switching to GTVD(50%), the variations in GTVDmax and GTVDmean decreased significantly, compared with variations observed for PTVD95% (p < 0.01), but the variation in GTVDmin increased significantly (p < 0.01). Upon switching to the GTVD(98%), the variation in GTVDmean decreased significantly compared with that observed for PTVD95% (p < 0.01). Conclusion: Switching from prescriptions based on 95% of the planning target volume to those based on 98% of the gross tumor volume decreased variations among cases in the overall gross tumor volume dose. Overall, prescriptions based on 98% of the gross tumor volume appear to be more suitable than those based on 95% of the planning target volume in cases of small peripheral lung tumors treated with stereotactic body radiotherapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Volume Dose Prescription in Stereotactic Body Radiotherapy for Lung Cancer
    Terahara, A.
    Saotome, N.
    Miyamoto, K.
    Omori, M.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S207 - S207
  • [2] Dose Discrepancy between the Gross Tumor Volume and the Planning Target Volume By Surrounding Density in Stereotactic Body Radiotherapy for Stage I Non-Small Cell Lung Cancer
    Uchiyama, F.
    Nakayama, H.
    Naka, G.
    Takeda, Y.
    Minamimoto, R.
    Tajima, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E536 - E537
  • [3] Feasibility study of stereotactic body radiotherapy for peripheral lung tumors with a maximum dose of 100 Gy in five fractions and a heterogeneous dose distribution in the planning target volume
    Takeda, Atsuya
    Oku, Yohei
    Sanuki, Naoko
    Eriguchi, Takahisa
    Aoki, Yousuke
    Enomoto, Tatsuji
    Kaneko, Takeshi
    Nishimura, Shuichi
    Kunieda, Etsuo
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) : 988 - 995
  • [4] Internal Target Volume interfraction changes and dose coverage in Stereotactic Body Radiotherapy for lung tumors
    L. Monroy Anton, J.
    Hernandis Barbera, J.
    Soler Tortosa, M.
    Lopez Munoz, M.
    Navarro Bergada, A. V.
    Estornell Gualde, M. A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S631 - S632
  • [5] Robust optimization of the Gross Tumor Volume compared to conventional Planning Target Volume-based planning in photon Stereotactic Body Radiation Therapy of lung tumors
    Fink, Thomas L.
    Kristiansen, Charlotte
    Hansen, Torben S.
    Hansen, Torben F.
    Thing, Rune S.
    ACTA ONCOLOGICA, 2024, 63 : 448 - 455
  • [6] Interfraction Internal Target Volume dose coverage in Stereotactic Body Radiotherapy for infradiafragmatic tumor
    Asensio Martinez, M.
    Borreda Talon, V.
    Monroy Anton, J. L.
    Hernandis Barbera, J.
    Marco Collado, M. J.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S909 - S910
  • [7] Is internal target volume accurate for dose evaluation in lung cancer stereotactic body radiotherapy?
    Peng, Jiayuan
    Zhang, Zhen
    Wang, Jiazhou
    Xie, Jiang
    Hu, Weigang
    ONCOTARGET, 2016, 7 (16) : 22523 - 22530
  • [8] Planning target volume (PTV) reduction for gated stereotactic body radiotherapy(SBRT) of lung tumors
    Kraus, K.
    Wilkens, J. J.
    Oechsner, M.
    Combs, S. E.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S893 - S893
  • [9] Stereotactic body radiotherapy for patients with non-small-cell lung cancer using RapidArc delivery and a steep dose gradient: prescription of 60% isodose line of maximum dose fitting to the planning target volume
    Tsurugai, Yuichiro
    Takeda, Atsuya
    Sanuki, Naoko
    Eriguchi, Takahisa
    Aoki, Yousuke
    Oku, Yohei
    Akiba, Takeshi
    Sugawara, Akitomo
    Kunieda, Etsuo
    JOURNAL OF RADIATION RESEARCH, 2019, 60 (03) : 364 - 370
  • [10] DOSE-VOLUME COMPARISON OF PROTON RADIOTHERAPY AND STEREOTACTIC BODY RADIOTHERAPY FOR NON-SMALL-CELL LUNG CANCER
    Kadoya, Noriyuki
    Obata, Yasunori
    Kato, Takahiro
    Kagiya, Masaru
    Nakamura, Tatsuya
    Tomoda, Takuya
    Takada, Akinori
    Takayama, Kanako
    Fuwa, Nobukazu
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (04): : 1225 - 1231