Dynamic range of safe electrical stimulation of the retina

被引:4
|
作者
Butterwick, Alexander F. [1 ]
Vankov, Alexander [2 ,3 ]
Huie, Phil [2 ,3 ]
Palanker, Daniel V. [2 ,3 ]
机构
[1] Stanford Univ, Hansen Expt Phys Lab, 445 Via Palou, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, Dept Ophthalmol, Stanford, CA 94305 USA
[3] Stanford Univ, Hansen Expt Phys Labs, Stanford, CA 94305 USA
来源
OPHTHALMIC TECHNOLOGIES XVI | 2006年 / 6138卷
关键词
retinal prostheses; propidium iodide; electrical stimulation; damage threshold;
D O I
10.1117/12.650652
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Electronic retinal prostheses represent a potentially effective approach for restoring some degree of sight in blind patients with retinal degeneration. However, levels of safe electrical stimulation and the underlying mechanisms of cellular damage are largely unknown. We measured the threshold of cellular damage as a function of pulse duration, electrode size, and number of pulses to determine the safe range of stimulation. Measurements were performed in-vitro on embryonic chicken retina with saline-filled glass pipettes for stimulation electrodes. Cellular damage was detected using Propidium Iodide fluorescent staining. Electrode size varied from 115 mu m to 1mm, pulse duration from 6 mu s to 6ms, and number of pulses from 1 to 7,500. The threshold current density was independent of electrode sizes exceeding 400 mu m. With smaller electrodes the current density was scaling reciprocal to the square of the pipette diameter, i.e. acting as a point source so that the damage threshold was determined by the total current in this regime. The damage threshold current measured with large electrodes (1mm) scaled with pulse duration as t(-0.5), which is characteristic of electroporation. For repeated electrical pulsed exposure on the retina the threshold current density varied between 0.059 A/cm2 at 6ms to 1.3 A/cm2 at 6 mu s. The dynamic range of safe stimulation, i.e. the ratio of damage threshold to stimulation threshold was found to be duration-dependent, and varied from 10 to 100 at pulse durations varying between 10 mu s to 10ms. Maximal dynamic range of 100 was observed near 1ms pulse durations.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Chronic Electrical Stimulation Of The Retina Via Suprachoroidal Electrodes Is Safe
    Nayagam, David
    Williams, Richard
    Shivdasani, Mohit
    Salinas-La Rosa, Cesar
    Allen, Penelope
    McGowan, Ceara
    Luu, Chi
    Ayton, Lauren
    Williams, Chris
    Shepherd, Robert
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [2] Dynamic response of the human retina to pulsed optical and electrical stimulation
    Akchurin, GG
    Bakutkin, VV
    Kamenskih, TG
    Zemskova, TM
    Ahuja, P
    [J]. SARTOV FALL MEETING '99: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE, 2000, 4001 : 402 - 405
  • [3] Electrical coupling in the retina ganglion cell layer increases the dynamic range
    Cesar A Celis
    Rodrigo Publio
    Antonio C Roque
    [J]. BMC Neuroscience, 15 (Suppl 1)
  • [4] Electrical stimulation of the human retina
    Humayun, MS
    Weiland, JD
    de Juan, E
    [J]. RETINAL DEGENERATIVE DISEASES AND EXPERIMENTAL THERAPY, 1999, : 479 - 485
  • [5] Focal electrical stimulation of the retina
    Weitz, Andrew C.
    Nanduri, Devyani
    Greenberg, Robert Jay
    Humayun, Mark S.
    Chow, Robert H.
    Weiland, James D.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [6] Expanding Dynamic Range of Electrical Stimulation Using Anesthetic Cream
    Hamazaki, Takumi
    Saito, Taiga
    Kaneko, Seitaro
    Kajimoto, Hiroyuki
    [J]. HAPTICS: SCIENCE, TECHNOLOGY, APPLICATIONS, EUROHAPTICS 2022, 2022, 13235 : 180 - 188
  • [7] Electrical stimulation of the rabbit retina with a sub-retinal electrode array: Charge and charge density limits for safe stimulation
    Shah, HA
    Chen, JH
    Herbert, CD
    Rizzo, JF
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [8] Electrical stimulation of retina in blind humans
    Weiland, JD
    Yanai, D
    Mahadevappa, M
    Williamson, R
    Mech, BV
    Fujii, GY
    Little, J
    Greenberg, RJ
    de Juan, E
    Humayun, MS
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2021 - 2022
  • [9] Pathology of damaging electrical stimulation in the retina
    Colodetti, L.
    Weiland, J. D.
    Colodetti, S.
    Ray, A.
    Seiler, M. J.
    Hinton, D. R.
    Humayun, M. S.
    [J]. EXPERIMENTAL EYE RESEARCH, 2007, 85 (01) : 23 - 33
  • [10] Chronic electrical stimulation of the canine retina
    Weiland, JD
    Fujii, GY
    Mahadevappa, M
    Greenberg, RJ
    Tameesh, M
    Guven, D
    de Juan, E
    Humayun, MS
    [J]. SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 2051 - 2052