Measurement of Placental Perfusion by Dynamic Contrast-Enhanced MRI at 4.7 T

被引:20
|
作者
Alison, Marianne [1 ,2 ]
Quibel, Thibault [1 ]
Balvay, Daniel [1 ,3 ]
Autret, Gwennhael [1 ,3 ]
Bourillon, Camille [1 ,4 ]
Chalouhi, Gihad E. [1 ,5 ]
Deloison, Benjamin [1 ,5 ]
Salomon, Laurent J. [1 ,5 ]
Cuenod, Charles Andre [1 ,4 ]
Clement, Olivier [1 ,3 ,4 ]
Siauve, Nathalie [1 ,4 ]
机构
[1] Univ Paris 05, Sorbonne Paris Cite, Paris Cardiovasc Res Ctr, INSERM,UMR 970, F-75737 Paris, France
[2] Univ Paris 07, Hop Robert Debre, Assistance Publ Hop Paris, Paris, France
[3] Univ Paris 05, Fac Med, Sorbonne Paris Cite, F-75737 Paris, France
[4] Hop Europeen Georges Pompidou, Assistance Publ Hop Paris, Paris, France
[5] Hop Necker Enfants Malad, Assistance Publ Hop Paris, Paris, France
关键词
contrast media; functional magnetic resonance imaging; perfusion; placental insufficiency; ARTERIAL INPUT FUNCTION; DCE-MRI; PHARMACOKINETIC PARAMETERS; BLOOD-FLOW; GADOPENTETATE DIMEGLUMINE; MOUSE MODEL; PERMEABILITY; PREGNANCY; RAT; BREAST;
D O I
10.1097/RLI.0b013e3182856a25
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purposes of this study were to develop quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) at 4.7 T for perfusion measurement and to evaluate the ability of this technique to distinguish between low and normal levels of placental perfusion in a controlled rat model. Materials and Methods: This study was approved by the animal care committee. Poor placental perfusion in the left uterine horn was achieved by ligation of the left uterine vascular pedicle on the 17th embryonic day in 12 pregnant rats. High-temporal resolution DCE-MRI (<1 second) was performed on the 19th embryonic day. Single-compartment analysis was used to calculate placental blood flow (F), volume fraction (Vb), and time delay (Dt) for each placenta and its 2 layers in both uterine horns. Mixed regression analysis was used to compare parameters between the ligated and nonligated horn and between placental layers. Results: We examined 53 placentas: 11 on the ligated side and 42 on the control side. On the control side, the mean (SD) values were 115 (72) mL/min per 100 mL for F, 38.6% (11.7%) for Vb, and 5.5 (5.3) seconds for Dt. Placental blood flow was significantly lower on the ligated side (66 [30] mL/min per 100 mL; P = 0.001). Placental blood flow and Vb were significantly higher, whereas Dt was significantly lower in the inner layer than in the outer layer in both horns (P=0.0001). Conclusions: Quantitative analyses of perfusion are feasible with DCE-MRI at 4.7 T. Dynamic contrast-enhanced magnetic resonance imaging can differentiate between low and normal levels of placental perfusion in a rat model. Dynamic contrast-enhanced magnetic resonance imaging at 4.7 T is a promising preclinical tool for quantifying and monitoring microvascularization.
引用
收藏
页码:535 / 542
页数:8
相关论文
共 50 条
  • [1] Dynamic contrast-enhanced myocardial perfusion MRI accelerated with k-t SENSE
    Plein, Sven
    Ryf, Salome
    Schwitter, Juerg
    Radjenovic, Aleksandra
    Boesiger, Peter
    Kozerke, Sebastian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (04) : 777 - 785
  • [2] Quantitative assessment of pulmonary perfusion with dynamic contrast-enhanced MRI
    Hatabu, H
    Tadamura, E
    Levin, DL
    Chen, Q
    Li, W
    Kim, D
    Prasad, PV
    Edelman, RR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (06) : 1033 - 1038
  • [3] Acral fibromyxoma: Findings on dynamic contrast-enhanced perfusion MRI
    Lacroix, Maxime
    Burns, Robert
    Campagna, Raphael
    Larousserie, Frederique
    Drape, Jean-Luc
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 59 - 61
  • [4] Hepatocellular Carcinoma: Perfusion Quantification With Dynamic Contrast-Enhanced MRI
    Taouli, Bachir
    Johnson, R. Scott
    Hajdu, Cristina H.
    Oei, Marcel T. H.
    Merad, Miriam
    Yee, Herman
    Rusinek, Henry
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (04) : 795 - 800
  • [5] Evaluation of lung tumor perfusion by dynamic contrast-enhanced MRI
    Pauls, Sandra
    Mottaghy, Felix M.
    Schmidt, Stefan A.
    Krueger, Stefan
    Moeller, Peter
    Brambs, Hans-Juergen
    Wunderlich, Arthur
    [J]. MAGNETIC RESONANCE IMAGING, 2008, 26 (10) : 1334 - 1341
  • [6] Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T1-weighted MRI at 3T
    Larsson, Henrik B. W.
    Hansen, Adam E.
    Berg, Hilde K.
    Rostrup, Egill
    Haraldseth, Olav
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 754 - 762
  • [7] Dynamic contrast-enhanced MRI perfusion in multiple sclerosis: Is this the way to go?
    Soni, Neetu
    Kumar, Sunil
    [J]. NEUROLOGY INDIA, 2018, 66 (03) : 669 - 670
  • [8] Dynamic, contrast-enhanced perfusion MRI in mouse gliomas: Correlation with histopathology
    Cha, S
    Johnson, G
    Wadghiri, YZ
    Jin, O
    Babb, J
    Zagzag, D
    Turnbull, DH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) : 848 - 855
  • [9] Fluctuations in tumor blood perfusion assessed by dynamic contrast-enhanced MRI
    Brurberg, Kjetil G.
    Benjaminsen, Ilana C.
    Dorum, Liv M. R.
    Rofstad, Einar K.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 473 - 481
  • [10] Dynamic Contrast-Enhanced MRI Perfusion Parameters as Imaging Biomarkers of Angiogenesis
    Kim, Sung Hun
    Lee, Hyeon Sil
    Kang, Bong Joo
    Song, Byung Joo
    Kim, Hyun-Bin
    Lee, Hyunyong
    Jin, Min-Sun
    Lee, Ahwon
    [J]. PLOS ONE, 2016, 11 (12):