Optimal Compensation of Delta-connected Dynamic Capacitor for Unbalanced Load

被引:0
|
作者
Wang, Xiaosheng [1 ]
Dai, Ke [1 ]
Chen, Xinwen [1 ]
Tan, Tian [1 ]
Dai, Ziwei [2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan, Hubei, Peoples R China
[2] Rensselaer Polytech Inst, Dept Elect Comp & Syst Engn, Troy, NY USA
基金
中国国家自然科学基金;
关键词
dynamic capacitor; unbalanced load; compensation ability; optimal compensation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper firstly verifies the relationship between reactive power compensation and unbalanced load compensation in three-phase three-wire system. In order to give full play to the effect of power capacitors, compensation ability and optimal parameter configuration for delta-connected capacitor bank to compensate reactive current and negative-sequence current are analyzed under unbalanced load. Dynamic Capacitor (D-CAP) is equivalent to continuously adjustable capacitor when duty ratio ranges from 0 to 1. Applying theory analysis about delta-connected capacitor bank on delta-connected D-CAP, an optimal compensation strategy is proposed to compensate reactive current and negative-sequence current as much as possible. Finally, Simulation results verify the effects of optimal parameter configuration and control strategy of D-CAP.
引用
收藏
页码:1524 / 1529
页数:6
相关论文
共 50 条
  • [1] Delta-Connected Cascaded H-Bridge Converter Application in Unbalanced Load Compensation
    Wu, Ping-Heng
    Chen, Hsin-Chih
    Chang, Yi-Ting
    Cheng, Po-Tai
    [J]. 2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 6043 - 6050
  • [2] Delta-Connected Cascaded H-Bridge Converter Application in Unbalanced Load Compensation
    Wu, Ping-Heng
    Chen, Hsin-Chih
    Chang, Yi-Ting
    Cheng, Po-Tai
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (02) : 1254 - 1262
  • [3] Design and Implementation of a STATCOM Based on a Multilevel FHB Converter with Delta-Connected Configuration for Unbalanced Load Compensation
    Chang, Wei-Neng
    Liao, Ching-Huan
    [J]. ENERGIES, 2017, 10 (07):
  • [4] A delta-connected MMCC-based active power conditioner for unbalanced load compensation and harmonic elimination
    Huang, Han
    Zhang, L.
    Oghorada, O. J. K.
    Mao, Mingxuan
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 118
  • [5] Derivation of zero-sequence circulating current and the compensation of delta-connected static var generators for unbalanced load
    Ma Fujun
    Luo An
    Xiong Qiaopo
    He Zhixing
    Xu Qianming
    [J]. IET POWER ELECTRONICS, 2016, 9 (03) : 576 - 588
  • [6] Research on the Unbalanced Compensation of Delta-Connected Cascaded H-Bridge Multilevel SVG
    Luo, Rui
    He, Yingjie
    Liu, Jinjun
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (11) : 8667 - 8676
  • [7] Research on the Unbalanced Compensation Range of Delta-connected Cascaded H-bridge Multilevel SVG
    Luo, Rui
    He, Yingjie
    Tu, Yiming
    Chen, Xingxing
    Liu, Jinjun
    [J]. 2018 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-NIIGATA 2018 -ECCE ASIA), 2018, : 3439 - 3444
  • [8] DC Capacitor Voltage Balancing Control for Delta-Connected Cascaded H-Bridge STATCOM Considering Unbalanced Grid and Load Conditions
    Jung, Jae-Jung
    Lee, Joon-Hee
    Sul, Seung-Ki
    Son, Gum Tae
    Chung, Yong-Ho
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (06) : 4726 - 4735
  • [9] DC Capacitor Voltage Balancing Control for Delta-Connected Cascaded H-Bridge STATCOM Considering the Unbalanced Grid and Load Conditions
    Jung, Jae-Jung
    Lee, Joon-Hee
    Sul, Seung-Ki
    Son, Gum Tae
    Chung, Yong-Ho
    [J]. 2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [10] Control method for delta-connected cascaded SVG under unbalanced condition
    [J]. 1600, Chinese Society for Electrical Engineering (36):