Performance of SensL C-Series SiPM with High Photoelectron Resolution at Cryogenic Temperatures

被引:0
|
作者
Biroth, Maik [1 ]
Achenbach, Patrick [1 ]
Lauth, Werner [1 ]
Thomas, Andreas [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Inst Kernphys, Mainz, Germany
关键词
Silicon photomultiplier; SiPM; MPPC; charge collection spectra; cryogenic temperature;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The C-Series of silicon photomultipliers (SiPM) from SensL provides devices with a fast response and high performance at low cost. The device's ability to detect light at temperatures of liquid nitrogen (77 K) and liquid helium (4 K) with high photoelectron resolution was demonstrated. Results include relative photon detection efficiency (PDE), gain, microcell capacitance, and cross-talk probability at different over-voltages, both at room and at cryogenic temperatures. At 77K the SiPM demonstrated significantly improved operating characteristics while at 4K the observed increase in break-down voltage, the reduction of PDE by a factor of 2-3, and the extensively dropped microcell capacitance degraded the performance.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Validation of LYSO Scintillators Coupled to SensL C-Series SiPM's Detectors
    Raptis, Evangelos
    McGrath, John
    IEEE SENSORS LETTERS, 2018, 2 (01)
  • [2] Ultra-low noise and exceptional uniformity of SensL C-Series SiPM sensors
    Jackson, C.
    Wall, L.
    O'Neill, K.
    McGarvey, B.
    Herbert, D.
    OPTICAL COMPONENTS AND MATERIALS XII, 2015, 9359
  • [3] Performance Evaluation of SensL SiPM Arrays for High-Resolution PET
    Thiessen, Jonathan D.
    Jackson, Carl
    O'Neill, Kevin
    Bishop, Daryl
    Kozlowski, Piotr
    Retiere, Fabrice
    Shams, Ehsan
    Stortz, Greg
    Thompson, Christopher J.
    Goertzen, Andrew L.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [4] Timing Resolution Performance Comparison for Fast and Standard Outputs of SensL SiPM
    Dolinsky, Sergei
    Fu, Geng
    Ivan, Adrian
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [5] SensL B-Series and C-Series silicon photomultipliers for time-of-flight positron emission tomography
    O'Neill, K.
    Jackson, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 169 - 172
  • [6] HIGH-RESOLUTION SPARK-CHAMBERS AT CRYOGENIC TEMPERATURES
    ATAC, M
    TAYLOR, WE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 455 - 455
  • [7] Study on SiPM performance at low temperatures between-60 °C and-20 °C
    Zhong, C.
    Luo, F. J.
    Zheng, B.
    Wang, X. D.
    Bu, M. Y.
    Zou, J.
    Deng, M. N.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (11):
  • [8] HIGH-RESOLUTION FREQUENCY SELECTIVE PHOTOCHEMISTRY OF PHYCOBILISOMES AT CRYOGENIC TEMPERATURES
    KOHLER, W
    FRIEDRICH, J
    FISCHER, R
    SCHEER, H
    JOURNAL OF CHEMICAL PHYSICS, 1988, 89 (02): : 871 - 874
  • [9] DESIGN AND PERFORMANCE OF A HIGH-RESOLUTION PHOTOELECTRON MICROSCOPE
    REMPFER, GF
    SKOCZYLAS, WP
    GRIFFITH, OH
    ULTRAMICROSCOPY, 1991, 36 (1-3) : 196 - 221
  • [10] High resolution photoelectron spectroscopy of C60-
    Wang, XB
    Ding, CF
    Wang, LS
    JOURNAL OF CHEMICAL PHYSICS, 1999, 110 (17): : 8217 - 8220