Study on the Development of a New Device with Dual Cameras for Evaluating Expiratory Nasal Flow

被引:0
|
作者
Doi, Rieko [1 ]
Akagami, Shuko [2 ]
Kondo, Katsuya [3 ]
Yoshida, Yu [4 ]
Chiuriki, Naoki [5 ]
Ikuta, Mika [5 ]
Saiki, Kazuki [5 ]
Kataoka, Tomoki [1 ]
Narai, Takashi [1 ]
Fujii, Nobuyuki [1 ]
Kawasaki, Makoto [1 ]
Otsuki, Kazuma [1 ]
Kodani, Isamu [1 ]
机构
[1] Tottori Univ, Fac Med, Sch Med, Div Oral & Maxillofacial Surg,Dept Sensory & Moto, Yonago, Tottori 6838504, Japan
[2] Tottori Univ Hosp, Div Oral & Maxillofacial Surg, Yonago, Tottori 6838504, Japan
[3] Tottori Univ, Dept Elect Engn & Comp Sci, Tottori 6808550, Japan
[4] Matsue Red Cross Hosp, Dept Oral & Maxillofacial Surg, Matsue, Shimane 6908506, Japan
[5] Tottori Univ Hosp, Dept Oral & Maxillofacial Surg Technol, Div Med Technol, Yonago, Tottori 6838504, Japan
关键词
expiratory nasal flow; Glatzel mirror; speech disorders; speech therapy; velopharyngeal insufficiency; UNILATERAL CLEFT-LIP; MAXILLOFACIAL GROWTH; PALATE;
D O I
10.33160/yam.2020.11.003
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background Use of the Glatzel mirror for measuring expiratory nasal flow in preschool children has the disadvantage of vagueness, and the mirror may induce fear and inhibition of interest in those children. In response to these limitations, we developed a new device with dual cameras for measuring expiratory nasal flow in 2 to 6 year old children. The aim of this study is to compare the Glatzel mirror and the new device, in terms of accurate assessment of expiratory nasal flow, children's feelings, and correlation to each child's profile. Methods This study evaluated 20 cleft lip and palate patients and 21 healthy children aged between 2 and 6 (under 7) years. After consent was granted, a 4-week screening period was undertaken followed by inspection at weeks 8, 16, 24, and 32. Each inspection was conducted while the children were asked to pronounce various sounds and comprised three stages: i) use of the Glatzel mirror, ii) subjective visual assessment using the new device, and iii) image recording by dual cameras of the new device. Questionnaires for the new device were administered at the initial and final inspections. To contrast the results between the Glatzel mirror and the new device, the numbers that indicated values of subjective visual assessment and camera assessment greater than the assessment values of the Glatzel mirror were compared. For measuring the children's responses to the new device compared with those to the Glatzel mirror, the answers to the questionnaires were compared. For the comparison of the children's profiles (age and sex) and feelings, the numbers of subjects who could use the new device were measured. Results The camera assessment of the new device indicated significantly greater values than that of the Glatzel mirror (P < 0.05). The feelings of the subjects to the new device mostly improved as the study progressed. Subjects aged 3 years and older were generally able to use the new device from the initial inspection. For both sexes, as the inspection progressed, the number occasions of successful use increased. Conclusion This study demonstrated the superiority of the new device with dual cameras to the Glatzel mirror in terms of functionality and attitude of children.
引用
收藏
页码:255 / 265
页数:11
相关论文
共 50 条
  • [1] Numerical Study of Inspiratory and Expiratory Flow in a Human Nasal Cavity
    Riazuddin, Vizy Nazira
    Zubair, Mohammed
    Abdullah, Mohammed Zulkifly
    Ismail, Rushdan
    Shuaib, Ibrahim Lutfi
    Hamid, Suzina Abdul
    Ahmad, Kamarul Arifin
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2011, 31 (03) : 201 - 206
  • [2] The development and validation of Digital Peak Expiratory Flow Device (D-PEF Device) for asthma monitoring
    Chaiparnich, Sirawich
    Manasilp, Natcha
    Poachanukoon, Orapan
    Saiphoklang, Narongkorn
    Tantibundhit, Charturong
    Vatcharavongvan, Pasitpon
    Phienphanich, Phongpan
    Kunumpol, Patthapol
    Pugongchai, Apiwat
    RESPIROLOGY, 2023, 28 : 309 - 310
  • [3] A self-regulated expiratory flow device for mechanical ventilation: a bench study
    Yang, Lianye
    Wiersema, Ubbo F.
    Bihari, Shailesh
    Broughton, Roy
    Roberts, Andy
    Kelley, Nigel
    Mcewen, Mark
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2024, 12 (01):
  • [4] Development of a High-Flow Nasal Cannula and Pharmaceutical Aerosol Combination Device
    Spence, Benjamin M.
    Longest, Worth
    Wei, Xiangyin
    Dhapare, Sneha
    Hindle, Michael
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2019, 32 (04) : 224 - 241
  • [5] The comparison study on accuracy of the novel digital peak expiratory flow device compared to conventional peak flow meters
    Chaiparnich, S.
    Manasilp, N.
    Poachanukoon, O.
    Saiphoklang, N.
    Tantibundhit, C.
    Vatcharavongvan, P.
    Kunumpol, P.
    Phienphanich, P.
    Pugongchai, A.
    Leelasittikul, K.
    Prompoom, N.
    Puangarom, S.
    ALLERGY, 2023, 78 : 54 - 54
  • [6] DEVELOPMENT OF A NEW DEVICE FOR HVAC AIR FLOW MEASUREMENT
    Rocha e Silva, Antonio
    Afonso, Clito
    ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [7] Evaluating Bronchodilator Delivery During Nasal High Flow Therapy: A Bench Study
    Reminiac, F.
    Landel, C.
    Philippe, M.
    Vecellio, L.
    Le Pennec, D.
    Ehrmann, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [8] Evaluation of a new nasal expiratory positive airway pressure (EPAP) device for the treatment of snoring and obstructive sleep apnea syndrome.
    Colrain, I
    Brooks, S.
    Black, J.
    SLEEP, 2007, 30 : A191 - A192
  • [9] Comparison of an expiratory flow accelerator device versus positive expiratory pressure for tracheobronchial airway clearance after lung cancer lobectomy: a preliminary study
    Rotolo, Nicola
    Cattoni, Maria
    D'Andria, Michele
    Cavanna, Laura
    Patrizio, Giorgia
    Imperatori, Andrea
    Nicolini, Antonello
    PHYSIOTHERAPY, 2021, 110 : 34 - 41
  • [10] Active Expiratory Support for Patients with ARDS - Results of the ActiveEx Study and Development of a prototypical Device for automated Application
    Witham, D.
    Kunz, J. V.
    Krebs, A. -C.
    Brueckner, K.
    Koerner, R.
    Eckardt, K. -U.
    Thamsen, P. U.
    Enghard, P.
    Peter, J.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2023, 118 (05)