Olecranon fracture fixation with a new implant: Biomechanical and clinical considerations

被引:22
|
作者
Koslowsky, Thomas C. [1 ,3 ]
Mader, Konrad [2 ,3 ]
Dargel, Jens [2 ,3 ]
Schadt, Ruediger [1 ]
Koebke, Juergen [3 ]
Pennig, Dietmar [2 ]
机构
[1] St Elizabeth Hosp, Dept Surg, D-50935 Cologne, Germany
[2] St Vinzenz Hosp, Dept Trauma & Orthoped Surg, D-50733 Cologne, Germany
[3] Univ Cologne, Dept Anat, D-50935 Cologne, Germany
关键词
FFS; Olecranon fractures; One-step fixation; Sawbone model; MASON TYPE-III; DISPLACED FRACTURES; PLATE FIXATION; MODEL; RECONSTRUCTION; DEVICE;
D O I
10.1016/j.injury.2009.01.129
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
This study aims to describe the first clinical results in the treatment of dislocated olecranon fractures with 2.2-mm, fine-threaded wires with a washer. Furthermore, in the second part of the article, the stability of these new implants has been compared to standard tension band wiring in a sawbone model. Patients: The radiological and clinical outcomes in 24 patients (mean age: 53.6 years) with 24 isolated Mayo type I and II fractures of the olecranon were evaluated in a prospective study after open reduction and internal fixation (ORIF) with a new fixation device (FFS; Orthofix(TM)). The quality of reduction with the implementation of 24 FFS constructions was compared with 24 tension band-wiring procedures performed by six different surgeons in a standard sawbone Mayo type IIa fracture model. Stability was tested in all constructs using a single cycle load to failure protocol (group I), cyclic loading for 300 cycles between 10 and 500 N (group II) and incremental sinusoidal loading from 10 to 200 N with an incremental increase of 10 N per cycle (group III) in a laboratory study. Results: The Morrey elbow score was excellent in 23 patients and good in one patient, with mean DASH score of 1.6. No implant migration, secondary dislocation or nonunion was observed. In the sawbone model, the quality of reduction was the same with the FFS implants compared to the tension band wiring in the sawbone model. Here, bending moments in all three groups showed no significant difference, whereas displacement at failure was significantly greater in the tension band-wiring group at a single cycle load (p = 0.017). Conclusion: Clinical results were comparable to tension band wiring and stability of the implants in the sawbone model was the same; thus, we conclude that the FFS technique can serve as an alternative treatment option for isolated olecranon fractures. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:618 / 624
页数:7
相关论文
共 50 条
  • [1] Wound Complications Following Olecranon Fracture Fixation: Implant and Soft Tissue Considerations
    Ahmad, Farhan
    Sabet, Andre D.
    Cohen, Mark
    Hein, Rachel
    Richard, Marc
    Simcock, Xavier
    Wysocki, Robert
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [2] Biomechanical analysis of olecranon fracture fixation in children
    Gicquel, P
    Maximin, MC
    Boutemy, T
    Karger, C
    Kempf, JF
    Clavert, JM
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2002, 22 (01) : 17 - 21
  • [3] Biomechanical Considerations in Osteoporotic Fracture Fixation
    Kumar, Ritabh
    INDIAN JOURNAL OF ORTHOPAEDICS, 2025, : 256 - 270
  • [4] IS THERE A TYPICAL OLECRANON FRACTURE - A CLASSIFICATION ACCORDING TO ANATOMICAL AND BIOMECHANICAL CONSIDERATIONS
    LORENZ, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1981, 135 (06): : 699 - 703
  • [5] Biomechanical considerations of fracture reduction and fixation in osteoporotic bone
    Chao, E
    Kim, Y
    Inoue, N
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S4 - S4
  • [6] New Intramedullary Locking Nail for Olecranon Fracture Fixation-An In Vitro Biomechanical Comparison With Tension Band Wiring
    Nowak, Tobias E.
    Burkhart, Klaus J.
    Mueller, Lars P.
    Mattyasovszky, Stefan G.
    Andres, Torsten
    Sternstein, Werner
    Rommens, Pol M.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (05): : E56 - E61
  • [7] Effect of Elbow Position on Load to Failure in Olecranon Fracture Fixation: A Biomechanical Cadaveric Study
    Lindeman, Robert W.
    Morris, Randal
    Weatherby, Paul
    Neustein, Adam
    Maassen, Nicholas H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (05) : 256 - 260
  • [8] Biomechanical rationale and evaluation of an implant system for rib fracture fixation
    Bottlang, M.
    Walleser, S.
    Noll, M.
    Honold, S.
    Madey, S. M.
    Fitzpatrick, D.
    Long, W. B.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2010, 36 (05) : 417 - 426
  • [9] Biomechanical rationale and evaluation of an implant system for rib fracture fixation
    M. Bottlang
    S. Walleser
    M. Noll
    S. Honold
    S. M. Madey
    D. Fitzpatrick
    W. B. Long
    European Journal of Trauma and Emergency Surgery, 2010, 36 : 417 - 426
  • [10] Evaluation of Intramedullary Olecranon Screw Fixation for Simple Olecranon Fractures: A Biomechanical Study
    Mcknight, Kelly N.
    Timmer, Tysen K.
    Montgomery, Mikayla D.
    Chong, Alexander CM.
    Potter, G. David
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2025, 50 (01): : 95e1 - 95e8