A compact collinear AOTF Raman spectrometer

被引:24
|
作者
Gupta, N
Fell, NF
机构
[1] Sensors and Electron Devices Direct., Army Research Laboratory, 2800 Powder Mill Road, Adelphi
关键词
acoustooptic tunable-filter; Raman spectra; organic energetic materials;
D O I
10.1016/S0039-9140(97)00145-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A compact, lightweight, completely packaged, uncooled, fully-automated collinear acousto-optic tunable-filter (AOTF) based spectrometer has been used to measure Raman spectra of three organic energetic materials (NQ, HMX, and TNT) using argon-ion laser excitation. Even though the resolution of the AOTF spectrometer is modest (7.4 cm(-1)) and it was not specifically designed for measuring Raman spectra, it has performed impressively. Such an instrument is specially useful for remote sensing and field measurements. In this paper, we will describe this instrument, present the measured Raman spectra and their comparison with the corresponding FT-IR spectra. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 50 条
  • [1] A compact AOTF Raman spectrometer
    Gupta, N
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 215 : U85 - U85
  • [2] AOTF Raman spectrometer for remote detection of explosives
    Gupta, N
    Dahmani, R
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2000, 56 (08) : 1453 - 1456
  • [3] Research System Based on Raman AOTF-Spectrometer
    Pozhar, V. E.
    Boritko, S. V.
    Kutuza, I. B.
    Karandin, A. V.
    Mazur, M. M.
    2018 WAVE ELECTRONICS AND ITS APPLICATION IN INFORMATION AND TELECOMMUNICATION SYSTEMS (WECONF), 2018,
  • [4] Compact high-resolution echelle-AOTF NIR spectrometer for atmospheric measurements
    Korablev, OI
    Bertaux, JL
    Vinogradov, II
    Kalinnikov, YK
    Nevejans, D
    Neefs, E
    Le Barbu, T
    Durry, G
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON SPACE OPTICS (ICSO 2004), 2004, 554 : 73 - 80
  • [5] Study on a novel quasi-collinear AOTF
    Wen, CJ
    Yang, JS
    Zhang, LM
    Xu, HH
    PASSIVE COMPONENTS AND FIBER-BASED DEVICES, PTS 1 AND 2, 2005, 5623 : 243 - 247
  • [6] Quasi-collinear AOTF with improved resolution
    Pushkareva, M
    Parygin, V
    ACOUSTO-OPTICS AND APPLICATIONS IV, 2001, 4514 : 147 - 152
  • [7] Raman shift calibration of a compact multichannel spectrometer
    Vickers, TJ
    Mann, CK
    APPLIED SPECTROSCOPY, 1999, 53 (12) : 1617 - 1622
  • [8] AOTF spectrometer for water pollutant monitoring
    Gupta, N
    Dahmani, R
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 751 - 752
  • [9] Reflection Grating Spectrometer Based on AOTF
    Qian, Tang
    Qing, Zhang Guo
    Min, Zhang Chun
    Chang, Zhao Bao
    SIXTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATIONS, 2020, 11455
  • [10] Compact Raman spectrometer system for low frequency spectroscopy
    Moser, Christophe
    Havermeyer, Frank
    OPTICAL COMPONENTS AND MATERIALS VII, 2010, 7598