Diffusion-tensor magnetic resonance imaging of the human heart in health and in acute myocardial infarction using diffusion-weighted echo-planar imaging technique with spin-echo signals

被引:2
|
作者
Mazur, Weronika [1 ,5 ]
Urbanczyk-Zawadzka, Malgorzata [2 ]
Czyz, Lukasz [3 ]
Kwiecien, Ewa [3 ]
Banys, Robert [2 ]
Musialek, Piotr [3 ]
Krzyzak, Artur T. [4 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, Krakow, Poland
[2] John Paul 2 Hosp, Dept Radiol, Krakow, Poland
[3] Jagiellonian Univ, John Paul II Hosp, Dept Cardiac & Vasc Dis, Krakow, Poland
[4] AGH Univ Sci & Technol, Fac Geol Geophys & Environm Protect, Krakow, Poland
[5] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, 30 Mickiewicza Ave, PL-30059 Krakow, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2022年 / 18卷 / 04期
关键词
acute myocardial infarction; cardiac diffusion-weighted imaging; cardiac diffusion tensor imaging; spin-echo echo-planar imaging; CARDIOLOGY; CELLS;
D O I
10.5114/aic.2022.121344
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Originally thought unsuitable due to proneness to myocardial motion and susceptibility artefacts, spin-echo echo planar imaging (SE-EPI) has gained attention for the cardiac diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) offering higher SNR and lower achievable echo time (TE).Aim: The application of DTI for patients with acute myocardial infarction (AMI) using our methodology developed on the basis of the SE-EPI sequence.Material and methods: Twelve patients with AMI and six healthy controls were enrolled in the preliminary DTI study within the CIRCULATE STRATEGMED 2 project. Our method relied on a pilot ECG-triggered DTI examination, based on which the initial evaluation was possible and allowed proper manipulation of TE (64/47 ms for patients/control), repetition time (TR) and ECG trigger delay in the consecutive DTI.Results: The study demonstrated that by using our algorithm it was possible to obtain DWI images showing infarct zones identified on T1-weighted images with late gadolinium-enhancement (LGE) with division into subtle and severe damage. Quantitative DTI showed increased mean diffusivity (MD) and decreased fractional anisotropy (FA) in the infarct compared to remote tissue. The application of B-matrix spatial distribution (BSD) calibration allowed the improvement of FA.Conclusions: Our algorithm is suitable for qualitative assessment of infarction zones with different severity. The analysis of the quantitative DTI showed that despite the lack of motion compensation blocks in the applied SE-EPI sequence, it was possible to approach the diffusion tensor parameter values reported for the myocardium.
引用
收藏
页码:416 / 422
页数:7
相关论文
共 50 条
  • [1] Radiological diagnosis of acute stroke -: Comparison of conventional MR imaging, echo-planar diffusion-weighted imaging, and spin-echo diffusion-weighted imaging
    Geijer, B
    Brockstedt, S
    Lindgren, A
    Ståhlberg, F
    Norrving, B
    Holtås, S
    ACTA RADIOLOGICA, 1999, 40 (03) : 255 - 262
  • [2] Cholesteatoma imaging using modified echo-planar diffusion-weighted magnetic resonance imaging
    Flook, E.
    Izzat, S.
    Ismail, A.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2011, 125 (01): : 10 - 12
  • [3] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373
  • [4] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    Heiland, S
    Dietrich, O
    Sartor, K
    NEURORADIOLOGY, 2001, 43 (06) : 442 - 447
  • [5] Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study
    Takatsu, Yasuo
    Yamamura, Kenichiro
    Yamatani, Yuya
    Takahashi, Daisuke
    Yoshida, Rei
    Asahara, Masaki
    Honda, Michitaka
    Miyati, Tosiaki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (01) : 89 - 99
  • [6] Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study
    Yasuo Takatsu
    Kenichiro Yamamura
    Yuya Yamatani
    Daisuke Takahashi
    Rei Yoshida
    Masaki Asahara
    Michitaka Honda
    Tosiaki Miyati
    Radiological Physics and Technology, 2022, 15 : 89 - 99
  • [7] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    S. Heiland
    O. Dietrich
    K. Sartor
    Neuroradiology, 2001, 43 : 442 - 447
  • [8] A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging
    Gui, Minzhi
    Peng, Huiling
    Carew, John D.
    Lesniak, Maciej S.
    Arfanakis, Konstantinos
    NEUROIMAGE, 2008, 42 (04) : 1451 - 1462
  • [9] Increased-contrast, high-spatial-resolution, diffusion-weighted, spin-echo, echo-planar imaging
    Thompson, MR
    Venkatesan, R
    Kuppusamy, K
    Celik, A
    Lin, WL
    Kido, DK
    Haacke, EM
    RADIOLOGY, 1999, 210 (01) : 253 - 259
  • [10] Intravoxel incoherent motion diffusion-weighted imaging in nasopharyngeal carcinoma: comparison of the turbo spin-echo and echo-planar imaging techniques
    Liu, Yuan
    Hu, Liu
    Qian, Lijuan
    Chen, Manman
    Xu, Si
    Sun, Peng
    Huang, Jing
    Lei, Ziqiao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 9101 - 9111