Usefulness of combined BI-RADS analysis and Nakagami statistics of ultrasound echoes in the diagnosis of breast lesions

被引:24
|
作者
Dobruch-Sobczak, K. [1 ,2 ]
Piotrzkowska-Wroblewska, H. [2 ]
Roszkowska-Purska, K. [3 ]
Nowicki, A. [2 ]
Jakubowski, W. [4 ]
机构
[1] Canc Ctr & Inst Oncol M Sklodowska Curie Mem, Dept Radiol, Warsaw, Poland
[2] PAS, Inst Fundamental Technol Res, Warsaw, Poland
[3] Canc Ctr & Inst Oncol M Sklodowska Curie Mem, Dept Pathol, Warsaw, Poland
[4] Med Univ Warsaw, Dept Diagnost Imaging, Warsaw, Poland
关键词
MODE IMAGES; CLASSIFICATION; MASSES; FEASIBILITY; US; SONOGRAPHY; MANAGEMENT; BLOOD; FLOW;
D O I
10.1016/j.crad.2016.11.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To develop a method combining the statistics of the ultrasound backscatter and the Breast Imaging-Reporting and Data System (BI-RADS) classification to enhance the differentiation of breast tumours. MATERIALS AND METHODS: The Nakagami shape parameter m was used to characterise the scatter properties of breast tumours. Raw data from the radiofrequency (RF) echo-signal and B-mode images from 107 (32 malignant and 75 benign) lesions and their surrounding tissue were recorded. Three different characteristic values of the shape parameters of m (maximum [mLmax], minimum [mLmin] and average [mLavg]) and differences between m parameters (Delta mmax, Delta mmin, Delta mavg) of the lesions and their surrounding tissues were assessed. A lesion with a BI-RADS score of 3 was considered benign, while a lesion with a score of 4 was considered malignant (a cut-off of BI-RADS 3/4 was set for all patients). RESULTS: The area under the receiver operating characteristic (ROC) curve (AUC) was equal to 0.966 for BI-RADS, with 100% sensitivity and 54.67% specificity. All malignant lesions were diagnosed correctly, whereas 34 benign lesions were biopsied unnecessarily. In assessing the Nakagami statistics, the sum of the sensitivity and specificity was the best for mLavg (62.5% and 93.33%, respectively). Only four of 20 lesions were found over the cut-off value in BI-RADS of 4a. When comparing the differences in m parameters, Delta mavg had the highest sensitivity of 90% (only three of 32 lesions were false negative). These three lesions were classified as BI-RADS category 4c. The combined use of B-mode and mLmin parameter improve the AUC up to 0.978 (p = 0.088), compared to BI-RADS alone. CONCLUSION: The combination of the parametric imaging and the BI-RADS assessment does not significantly improve the differentiation of breast lesions, but it has the potential to better identify the group of patients with mainly benign lesions that have a low level of suspicion for malignancy with a BI-RADS score of 4a. (C) 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:339.e7 / 339.e15
页数:9
相关论文
共 50 条
  • [1] Breast lesions categorized as ultrasound BI-RADS® 3
    Doutriaux-Dumoulin, Isabelle
    IMAGERIE DE LA FEMME, 2022, 32 (2-3) : 36 - 41
  • [2] The value of ultrasound elastography combined with multi-parameters in the diagnosis of BI-RADS 4 breast lesions
    Shi, Jian
    Chen, Luzeng
    Bin Wang
    Zhang, Hong
    Xu, Ling
    Ye, Jingming
    Liu, Yinhua
    Shao, Yuhong
    Sun, Xiuming
    Zou, Yinghua
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (05) : 1077 - 1089
  • [3] Interobserver variability of ultrasound elastography and the ultrasound BI-RADS lexicon of breast lesions
    Chang Suk Park
    Sung Hun Kim
    Na Young Jung
    Jae Jung Choi
    Bong Joo Kang
    Hyun Seouk Jung
    Breast Cancer, 2015, 22 : 153 - 160
  • [4] Interobserver variability of ultrasound elastography and the ultrasound BI-RADS lexicon of breast lesions
    Park, Chang Suk
    Kim, Sung Hun
    Jung, Na Young
    Choi, Jae Jung
    Kang, Bong Joo
    Jung, Hyun Seouk
    BREAST CANCER, 2015, 22 (02) : 153 - 160
  • [5] BI-RADS 4 breast lesions: could multi-mode ultrasound be helpful for their diagnosis?
    Liu, Gang
    Zhang, Meng-Ke
    He, Yan
    Liu, Yuan
    Li, Xi-Ru
    Wang, Zhi-Li
    GLAND SURGERY, 2019, 8 (03) : 258 - 270
  • [6] Value of ultrasound elastography in diagnosis of BI-RADS 4B breast lesions based on conventional ultrasound
    Gong, Xia
    Wang, Yi
    Wu, Weihua
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 2561 - 2566
  • [7] Values of contrast-enhanced ultrasound combined with BI-RADS in differentiating benign and malignant breast lesions
    Cai, Zhenyu
    Li, Mingkui
    Zhang, Yiqing
    Ru, Rongrong
    Yao, Chun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (11): : 11957 - 11964
  • [8] Abnormal BI-RADS Breast Lesions in Gabon
    Ivanga, Mahine
    Koumakpayi, Ismael H.
    Engohan-Aloghe, Corinne
    Mipinda, Gaelle Ebinda
    Mboumba, Chermine
    Ankely, Junie Chansy K.
    Belembaogo, Ernest
    BREAST JOURNAL, 2017, 23 (05): : 615 - 616
  • [9] A Practical Computer Aided Diagnosis System for Breast Ultrasound Classifying Lesions into the ACR BI-RADS Assessment
    Su, Hsin-Ya
    Lien, Chung-Yueh
    Huang, Pai-Jung
    Chu, Woei-Chyn
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (03) : 426 - 436
  • [10] CLINICAL USEFULNESS OF BREAST-SPECIFIC GAMMA IMAGING FOR BI-RADS 4 LESIONS
    Cho, M. J.
    Yang, J.
    Yu, Y.
    Park, K. S.
    BREAST, 2013, 22 : S43 - S43